1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – INSTALLATION; sensor into the process pipe.; Sensor Section on page 6.; SIDE VIEW
  • Page 3 – FIGURE 3. Installing model 141 sensor; INSTALLATION – 141 SENSOR; fitting until the sensor is correctly positioned.; FIGURE 4. Installing model 142 sensor
  • Page 4 – WIRING; WIRE COLOR AND CONNECTIONS IN SENSOR; COLOR FUNCTION; FIGURE 6. Model 54eC Wiring; WIRING DIAGRAMS
  • Page 6 – RETRACTING AND INSERTING THE MODEL 140 SENSOR; RETRACTING THE SENSOR; sensor tightening procedure illustrated in Figure 2.; CAUTION; INSERTING THE SENSOR; DO NOT open the ball valve.; WARNING
  • Page 7 – Slowly open the valve.; Stand clear of the sensor.; REMOVING AND REINSTALLING THE MODEL 142 SENSOR; REMOVING THE SENSOR
  • Page 8 – CALIBRATION
  • Page 9 – MAINTENANCE; CLEANING THE SENSOR
  • Page 10 – PN; Ball valve kit for Model 140 sensor; REPLACEMENT PARTS
  • Page 11 – PROBLEM; FIGURE 14. Checking Temperature Element
  • Page 12 – Specifications subject to change without notice.
Loading the manual

Models 140, 141, and 142

Conductivity Sensors

Instruction Sheet

PN 51A-140/rev.E
December 2010

SENSOR SPECIFICATIONS

For additional information, please visit our website

at

www.emersonprocess.com/raihome/liquid/

.

CAUTION

CAUTION

SPECIFICATIONS

MODEL 140

MODEL 141

MODEL 142

Wetted Materials

316SS, PEEK, Viton

1

316SS, PEEK, Viton

1

316SS, Viton

1

PEEK (high

temp options), Kel-F

2

(stand

temp options)

Temperature (standard)

302ºF (150ºC) max

see graph

see graph

Temperature (high temp)

392ºF (200ºC) max

see graph

see graph

Maximum Pressure

100 psig (791 kPa abs)

see graph

see graph

INSTALLATION HARDWARE FOR 140 SENSOR

SPECIFICATION

Ball valve kit (PN 23724-00)

Fitting kit (PN 23730-00)

Wetted Materials

316SS

316SS, PEEK

Viton

1

is a registered trademark of DuPont Performance Elastomers.

Kel-F

2

is a registered trademark of 3M

SENSOR/PROCESS

APPLICATION COMPATIBILITY

The wetted sensor materials may not be compatible
with process com position and operating conditions.
Application compat ibility is entirely the responsibility
of the user.

BEFORE REMOVING THE SENSOR, be
absolutely certain the process pressure is
reduced to 0 psig and the process tempera-
ture is at a safe level!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; sensor into the process pipe.; Sensor Section on page 6.; SIDE VIEW

Keep 1/4 inch (6 mm) clearance between electrodesand piping. The electrodes must be completely sub-merged in the process liquid, i.e., to the level of thethreaded connection. See Figure 1 for recommendedorientation. If the sensor is installed in a side stream with thesample draining to open atmosphe...

Page 3 - FIGURE 3. Installing model 141 sensor; INSTALLATION – 141 SENSOR; fitting until the sensor is correctly positioned.; FIGURE 4. Installing model 142 sensor

3 MODEL 140,141, and 142 sensors INSTALLATION FIGURE 3. Installing model 141 sensor DWG. NO. REV. 40014204 B INSTALLATION – 141 SENSOR 1. Install the sensor in a 3/4-inch NPT weldalet or in a 1-inch pipe tee.2. Remove the plastic shipping cap from the sensor.3. Screw the sensor into the fitting. Use...

Page 4 - WIRING; WIRE COLOR AND CONNECTIONS IN SENSOR; COLOR FUNCTION; FIGURE 6. Model 54eC Wiring; WIRING DIAGRAMS

RTD RTD in RTD sense RTD return MODEL 140,141, and 142 sensors WIRING WIRING All 140 series sensors have a junction box mounted on the back of the sensor. Wiring connections in the junction boxare shown in Figure 5. Figure 5. Sensor junction box wiring. Terminals in thejunction box are not numbered....

Other Emerson Models