Emerson 122A- User Manual

Emerson 122A

Emerson 122A– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Specifications; Principle of Operation; Refer to Figure 2. The flow through the Type 122A
  • Page 4 – Installation; Overpressure Protection; WARNING; Maintenance; WARNING
  • Page 5 – Parts Ordering; When corresponding with your local Sales Office
  • Page 6 – Parts List
Loading the manual

Type 122A

D100263X012

March 2013

Instruction Manual

Form 2279

www.fisherregulators.com

Type 122A Three-Way Switching Valve

!

WARNING

Failure to follow these instructions or

to properly install and maintain this

equipment could result in an explosion,

fi re and/or chemical contamination

causing property damage and personal

injury or death.
Fisher

®

switching valves must be

installed, operated, and maintained

in accordance with federal, state, and

local codes, rules and regulations,

and Emerson Process Management

Regulator Technologies, Inc. (Regulator

Technologies) instructions.
If the switching valve vents gas or a

leak develops in the system, service

to the unit may be required. Failure

to correct trouble could result in a

hazardous condition.
Installation, operation, and maintenance

procedures performed by unqualifi ed

personnel may result in improper

adjustment and unsafe operation. Either

condition may result in equipment

damage or personal injury. Only

qualifi ed personnel shall install, operate,

and maintain the Type 122A three-way

switching valve.

Introduction

Scope of the Manual

This instruction manual includes installation,

adjustment, maintenance, and parts ordering

information for the Type 122A three-way

switching valve.

Description

The Type 122A three-way switching valve (see

Figure 1) is a high-capacity, economical three-way

pneumatic switching valve for on-off applications. This

valve can be used for diverging or converging gaseous

service, diverging liquid service with gas-loaded

liquids, and converging liquid service. Six spring

ranges are available for control pressures from 3 to

150 psig / 0.21 to 10.3 bar.

Figure 1. Type 122A Three-Way Switching Valve

W3141-1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Specifications; Principle of Operation; Refer to Figure 2. The flow through the Type 122A

Type 122A 2 Specifications The Specifications section lists the specifications for Type 122A three-way switching valve. Factory specification is stamped on the nameplate fastened on the valve at the factory. Table 1. Set Pressure Ranges SET PRESSURE RANGES PRESSURE BUILD-UP ABOVE SETPOINT REQUIRED F...

Page 4 - Installation; Overpressure Protection; WARNING; Maintenance; WARNING

Type 122A 4 Installation ! WARNING To avoid personal injury or equipment damage caused by bursting of pressure-retaining parts or explosion of accumulated gas, do not exceed the pressure or temperature limits in Specifications, and do not use the Type 122A valve for installations where water hammer ...

Page 5 - Parts Ordering; When corresponding with your local Sales Office

Type 122A 5 Disassembly 1. Loosen the locknut (key 30). Rotate the adjusting screw (key 7) counterclockwise until all compression has been relieved from the spring (key 3). 2. Disconnect piping from the bottom connector (key 36). Unscrew and remove the bottom connector. 3. To remove the lower seat r...

Other Emerson Models