Emerson 1052- User Manual

Emerson 1052

Emerson 1052– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Instruction Manual
  • Page 3 – Note; Description; Specifications; Installation; WARNING
  • Page 4 – CAUTION
  • Page 6 – before
  • Page 7 – Loading Connection; For size 40 through 60 actuators:; Run either; For size 70 actuators:; Run either pipe or; Adjustment; Turnbuckle Adjustment
  • Page 8 – Slowly stroke the; Type 1052 Spring Adjustment; Initial Setting; with the; Stroking Range
  • Page 9 – Principle of Operation; even when the valve has
  • Page 11 – For Size; Assembly; For Size 40 and 60 actuators:
  • Page 12 – For actuator designs without a set screw; Installing the diaphragm:
  • Page 13 – Changing Actuator Mounting; Style A
  • Page 14 – not
  • Page 15 – Top-Mounted Handwheel Assembly; is attached to; Adjustable Up Travel Stop
  • Page 16 – For Adjustable Up Travel Stops:; Drive out the groove pin; For Adjustable Down Travel Stops:
  • Page 17 – Locking Mechanism; Installing the Locking Mechanism
  • Page 18 – Operating the Locking Mechanism; To Unlock the Actuator; To Lock the Actuator
  • Page 21 – Parts Ordering; Parts Kits; Top-Mounted Handwheel Retrofit Kits; Kit Number 1; Pipe-Away Vent Retrofit Kit
  • Page 22 – Parts List
Loading the manual

www.Fisher.com

D100319X012

Type 1051 and 1052 Style F and G
Size 40, 60, and 70 Rotary Actuators

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . .

Description

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Actuator Mounting

4

. . . . . . . . . . . . . . . . . . . . . . . .

Valve Flow Direction

6

. . . . . . . . . . . . . . . . . . . . . .

Loading Connection

7

. . . . . . . . . . . . . . . . . . . . . . .

Turnbuckle Adjustment

7

. . . . . . . . . . . . . . . . . . . .

Type 1052 Spring Adjustment

8

. . . . . . . . . . . . . .

Initial Setting

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Stroking Range

8

. . . . . . . . . . . . . . . . . . . . . . . . .

Principle of Operation

9

. . . . . . . . . . . . . . . . . . . . .

Maintenance

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembly

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Changing Actuator Mounting

13

. . . . . . . . . . . . . .

Top-Mounted Handwheels and

Adjustable Travel Stops

14

. . . . . . . . . . . . . . . . .

Principle of Operation for Handwheels

14

. . . . . .

Handwheel Maintenance and Adjustable

Travel Stop

15

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Locking Mechanism

17

. . . . . . . . . . . . . . . . . . . . . . .

Installing the Locking Mechanism

17

. . . . . . . . . .

Operating the Locking Mechanism

18

. . . . . . . . .

Pipe-Away Vent

20

. . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

21

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Reference

21

. . . . . . . . . . . . . . . . . . . . . . . . . .

Introduction

Scope of Manual

This instruction manual includes installation,
adjustment, maintenance, and parts ordering
information for the Type 1051 (size 40 and 60) and
Type 1052 (Size 40, 60, and 70) pneumatic piston
rotary actuator with F and G mounting adaptations
(see figure 1).
The G mounting adaptation is for Type 7600 and
9500 valves, and the F mounting adaptation is for all

Figure 1. Vee-Ball

r

Valve with Type 1052 Actuator and

Type DVC6020 Digital Valve Controller

W8508-2

other eccentric disc or Vee-Ball

r

valves. Also, this

instruction manual provides information for the
optional top-mounted handwheel, up and down
travel stops, locking mechanism, and pipe-away
vent.

Instructions for the control valve, positioner,
accessories, and other sizes of actuators are
covered in separate instruction manuals.

Top-Mounted handwheels can be applied for
infrequent service as a manual handwheel actuator.
Also, an adjustable up travel stop can be added to
the actuator to limit its stroke in the upward direction,
or an adjustable down travel stop can be added to
limit actuator stroke in the downward direction.

Do not install, operate, or maintain a Type 1051 or
1052 actuator without first

D

being fully trained and

qualified in valve, actuator, and accessory
installation, operation, and maintenance, and

D

carefully reading and understanding the contents of
this manual. If you have any questions about these
instructions, contact your Emerson Process
Management

t

sales office before proceeding.

Instruction Manual

Form 5062
May 2008

1051 & 1052 F & G Actuators

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Emerson 1052

Summary

Page 2 - Instruction Manual

1051 & 1052 F & G Actuators Instruction Manual Form 5062 May 2008 2 Table 1. Type 1051 and 1052 Actuator Specifications Operation Direct Acting: Increasing loading pressure extends the diaphragm rod out of the spring barrel Service: Type 1051: For on-off or throttling service with positioner...

Page 3 - Note; Description; Specifications; Installation; WARNING

1051 & 1052 F & G Actuators Instruction Manual Form 5062May 2008 3 Figure 2. Typical Type 1052 Actuator Adjustable Spring Seat W4742-1/IL SPRING SPRING SEAT SPRING ADJUSTER Note Neither Emerson, Emerson ProcessManagement, nor any of their affiliatedentities assumes responsibility for thesele...

Page 4 - CAUTION

1051 & 1052 F & G Actuators Instruction Manual Form 5062 May 2008 4 Table 3. Recommended Bolting Torques DESCRIPTION KEY ACTUATOR SIZE DESCRIPTION, KEY NUMBER 40 60 70 NUMBER Size N S m lbf S ft Size N S m lbf S ft Size N S m lbf S ft Diaphragm Casing, 5 3/8-24 27 20 3/8-24 27 20 3/8-24 27 2...

Other Emerson Models