NOTE:
It is important to insure proper ventilation. Allow a
minimum clearance of 6 inches (152 mm) in front and 3
inches (76mm) in the rear of the unit. If unit is to be in-
stalled in an enclosure, allow the following clearances
around unit 1 inch (25mm) each side, 3 inches (76mm) in
the rear, 3 inches (76mm) inches above wall.
This chiller has been designed for use with potable water
and includes an o-ring seal on the drain plug. This fitting
should be replaced if the unit is to be used with more
aggressive fluids.
Refrigeration Packages
Installation Instructions
A = 3/8" O.D. TUBE WATER OUT
B = 3/8" O.D. TUBE WATER INLET
C = 3/8" O.D. TUBE TANK DRAIN
D = TEMPERATURE ADJUSTMENT
E = ELECTRICAL