Elkay EDFPA117FPRAC - Manual
Elkay EDFPA117FPRAC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – that the fountain is installed on.
- Page 3 – EDFPA117FPRAC ROUGH-IN
- Page 4 – PARTS LIST; INSTALLATION INSTRUCTIONS
97729C (Rev. C - 1/04)
EDFPA117FPC, EDFPA117FPRAC
Installation/Care/Use Manual
EDFPA117FPC & EDFPA117FPRAC
Swirlflo
®
Freeze Resistant Fountain
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
FIG. 1
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
TUBE IS
SECURED
IN POSITION
SIMPLY PUSH IN
TUBE TO ATTACH
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
OPERATION OF QUICK CONNECT FITTINGS
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-
TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton
contains the Freeze Resistant Package
LK616A
that is installed on an interior heated
wall. Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
Installer
EDFPA117FPC
EDFPA117FPRAC
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
97729C (Rev. C - 1/04) EDFPA117FPC, EDFPA117FPRAC FIG. 3 EDFPA117FPC ROUGH-IN PAGE 2 LEGEND: A = 7/8" (22mm) DIA. HOLE FOR WATER SUPPLY TUBE B = 1-3/4" (44mm) DIA. HOLE FOR WASTE LINE C = 1/4" (6mm) DIA. HOLE FOR MOUNTING PLATE TO WALL *Note: All dimensions are taken from the finished fl...
97729C (Rev. C - 1/04) EDFPA117FPC, EDFPA117FPRAC PAGE 3 LEGEND: A = 7/8" (22mm) DIA. HOLE FOR WATER SUPPLY TUBE B = 1-3/4" (44mm) DIA. HOLE FOR WASTE LINE C = 1/4" (6mm) DIA. HOLE FOR MOUNTING PLATE TO WALL *Note: All dimensions are taken from the finished floor on the side of the wall ...
97729C (Rev. C - 1/04) EDFPA117FPC, EDFPA117FPRAC PAGE 4 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484 DESCRIPTION 21705C 28322C 21810C 21822C 21823C 21845C 21846C 28227C 28229C 50198C 55001026 70...