97729C (Rev. C - 1/04)

EDFPA117FPC, EDFPA117FPRAC

Installation/Care/Use Manual

EDFPA117FPC & EDFPA117FPRAC

Swirlflo

®

Freeze Resistant Fountain

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO

WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY

OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK

INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN

INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING

THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER

SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING

PLUMBING SYSTEM.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

FIG. 1

NOTE: WATER FLOW

DIRECTION

BUILDING WATER

INLET

SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO COOLER

3/8" O.D. UNPLATED

COPPER TUBE CONNECT

COLD WATER SUPPLY

TUBE IS

SECURED

IN POSITION

SIMPLY PUSH IN

TUBE TO ATTACH

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

FIG. 2

OPERATION OF QUICK CONNECT FITTINGS

To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE

INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-

TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE

CODES. After installation, leave these instructions inside the fountain for future reference.

This Freeze Resistant Fountain is shipped in two separate cartons. The second carton

contains the Freeze Resistant Package

LK616A

that is installed on an interior heated

wall. Refer to the Freeze Resistant Package for the rough-in dimensions for installation.

Installer

EDFPA117FPC

EDFPA117FPRAC

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - that the fountain is installed on.

97729C (Rev. C - 1/04) EDFPA117FPC, EDFPA117FPRAC FIG. 3 EDFPA117FPC ROUGH-IN PAGE 2 LEGEND: A = 7/8" (22mm) DIA. HOLE FOR WATER SUPPLY TUBE B = 1-3/4" (44mm) DIA. HOLE FOR WASTE LINE C = 1/4" (6mm) DIA. HOLE FOR MOUNTING PLATE TO WALL *Note: All dimensions are taken from the finished fl...

Page 3 - EDFPA117FPRAC ROUGH-IN

97729C (Rev. C - 1/04) EDFPA117FPC, EDFPA117FPRAC PAGE 3 LEGEND: A = 7/8" (22mm) DIA. HOLE FOR WATER SUPPLY TUBE B = 1-3/4" (44mm) DIA. HOLE FOR WASTE LINE C = 1/4" (6mm) DIA. HOLE FOR MOUNTING PLATE TO WALL *Note: All dimensions are taken from the finished floor on the side of the wall ...

Page 4 - PARTS LIST; INSTALLATION INSTRUCTIONS

97729C (Rev. C - 1/04) EDFPA117FPC, EDFPA117FPRAC PAGE 4 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 DESCRIPTION 21705C 28322C 21810C 21822C 21823C 21845C 21846C 28227C 28229C 50198C 55001026 70...