Page 2 - - Manual Safety Symbols and Important; specific to this product.
2 Copyright© 2011 By Echo, Incorporated All Rights Reserved. T able of C onTenTs Introduction ................................................................ 2 - The Operator's Manual ....................................... 2 Safety .....................................................................
Page 3 - warning; CIRCLE AND SLASH SyMBOL; This symbol means the specific action; CaUTiOn
3 P ower B lower o Perator ' s M anual InTernaTIonal symbols Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape read and understand Operator's Manual. Fuel and oil mixture Symbol description/application Symbol form/shape Symbol description/application S...
Page 5 - DangEr
5 P ower B lower o Perator ' s M anual DangEr Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions and can cause serious injury or death. Read the Manuals • Provide all users of this equipment with the Operator’s Manual for instructions...
Page 6 - • Do not use blower if any part is missing or damaged.; ALWAyS; before removing obstructions, clearing debris, or servicing unit.; DO NOT; servicing dealer before using.; An Emission Control Label; is an EXAMPLE ONLY information on label varies by en; PRODUCT EMISSION DURABILITy (EMISSION COMPLIANCE PERIOD); listed in the Maintenance Section of this manual.
6 warning Use only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment com- bination. ECHO, INC. will not be responsible for the failure of cutting devices, attachments or accessories which have not been tested and approved by ECHO. Read and comply with all...
Page 7 - esCrIpTIon; instructions for specific information.; General Warning Decal (located on blower housing); Category ii
7 P ower B lower o Perator ' s M anual 10 11 12 1 2 3 5 6 7 4 d esCrIpTIon PB-500H Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instruc- tions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See P...
Page 8 - SPARK ARRESTOR MUFFLER OR SPARK ARRESTOR MUFFLER WITH CATALyST -; The muffler or; RECOIL STARTER HANDLE; Contains replaceable air filter element.; PURGE BULB; - Provides comfortable grip for directing air flow.
8 1. SAFETy DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR MUFFLER OR SPARK ARRESTOR MUFFLER WITH CATALyST - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing par...
Page 10 - Used by operator to direct and control air flow.; COMBINATION THROTTLE POSITION / STOP SWITCH BUTTON -
10 1. SAFETy DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR MUFFLER OR SPARK ARRESTOR MUFFLER WITH CATALyST - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing pa...
Page 11 - onTenTs
11 P ower B lower o Perator ' s M anual C onTenTs PB-500H ___ 1 - Power Head ___ 1 - Flex Pipe ___ 1 - Pipe w/swivel ___ 1 - Straight Pipe ___ 1 - Straight Pipe w/decal ___ 1 - Operator's Manual ___ 1 - Warranty Registration Card ___ 1 - Plastic Bag ___ 2 - Clamps w/screws ___ 1 - Stick Handle ___ 1...
Page 12 - A light lubricant may be used to ease assembly of flexible pipe to; NOTE
12 a ssembly PB-500H warning Never perform maintenance or assembly procedures with engine running or serious personal injury may result. InsTall blower pIpes / sTICk handle 1. Assemble clamps (A) onto both ends of flexible pipe (B). 2. Assemble straight pipe with swivel (C) into flexible pipe (B). 3...
Page 13 - InsTall; connection is firm. Do not force connection.
13 P ower B lower o Perator ' s M anual g PB-500T warning Never perform maintenance or assembly procedures with engine running or serious personal injury may result. InsTall blower pIpes ( T ) 1. Place guide loop (G) across clamp, and turn until clip fully engages clamp band. NOTE Clamp with cable g...
Page 14 - fuel; Fuel Requirements; NOT; certified oil, such as Echo; are covered for five; IMPORTANT; peraTIon
14 NOTICE: Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor performance, or severe engine damage and void the product warranty. Read and follow instructions in the Storage section of this manual. fuel warning Alternative fuels, such as E-15 (1...
Page 15 - Mixing Instructions; Handling Fuel
15 P ower B lower o Perator ' s M anual Mixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline. 2. Add the proper amount of 2-stroke oil to gasoline. 3. Close container and shake to mix oil with gasoline. 4. Add remaining gasoline, close fuel container, a...
Page 16 - Throttle Lever
16 sTarTIng Cold engIne • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for start - ing. Do not allow the rope to snap back in. Always hold the unit firmly. • (PB-500H): Rotate spring loaded throttle arm downward to a com - fortable operating position. PB-500H 1. Throttle Lever Move ...
Page 17 - sTarTIng; Pump purge bulb (D) until fuel is visible and flows freely in the; sToppIng; • Be certain engine is at idle, otherwise engine may continue to
17 P ower B lower o Perator ' s M anual sTarTIng warm engIne The starting procedure is the same as Cold Start except DO NOT close the choke. PB-500H 1. Throttle Lever Move throttle position lever (A) midway between idle and full throttle positions. PB-500T 1. Throttle Position / Stop Switch Button S...
Page 18 - Always wear safety glasses, hearing protection, a face filter mask; a lawn or flower bed.; dampening material with water/mist when necessary. Keep debris
18 operaTIng blower warning Engine exhaust IS HOT, and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause unconsciousness, serious in- jury, or death. Exhaust can cause serious burns. ALWAYS position unit so that exhaust is directed away from your face and body. warning Always wear ...
Page 19 - maInTenanCe; Level 1; = Moderate difficulty. Some specialized tools may be required.; REPOWER; Maintenance Kits and Parts to make your maintenance job easier.; gloves to protect hands from sharp edges and hot surfaces.
19 P ower B lower o Perator ' s M anual maInTenanCe InTervals m aInTenanCe Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want t...
Page 20 - Level; VERy
20 aIr fIlTer Level 1. Parts required: Repower TM Tune Up Kit NOTE Clean daily. 1. Close choke (Cold Start Position [ ]). This prevents dirt from entering the carburetor throat when the air filter is removed. Brush accumulated dirt from air cleaner area. 2. Remove air filter cover. Brush dirt from i...
Page 21 - spark; CoolIng; Cleaning Grill
21 P ower B lower o Perator ' s M anual spark plug Level 1. Parts Required: Repower TM Tune Up Kit IMPORTANT Use only NGK BPM8Y spark plug (BPMR8Y in Canada) other - wise severe engine damage may occur. 1. Remove spark plug , and check for fouling, worn and rounded center electrode. 2. Clean the plu...
Page 22 - Spark Arrestor Screen; Spark arrestor screen, Gasket; Carbon deposits in muffler will cause a drop in engine output and; Cleaning Cylinder Fins; Disconnect spark plug lead from spark plug.
22 exhausT sysTem Spark Arrestor Screen Level 2. Parts Required: Spark arrestor screen, Gasket IMPORTANT Carbon deposits in muffler will cause a drop in engine output and overheating. Spark arrestor screen must be checked periodically. 1. Remove spark plug and engine cover (five screws). 2. Remove s...
Page 23 - Exhaust Port Cleaning; Level 2; Never use a metal tool to scrape carbon from the exhaust port.
23 P ower B lower o Perator ' s M anual Exhaust Port Cleaning Level 2 Parts Required: As needed: Muffler gasket 1. Remove spark plug lead from spark plug, and remove engine cover. 2. Place piston at top dead center. Remove muffler (A) and muffler gasket (B ). 3. Use a wood or plastic scraping tool t...
Page 24 - High Altitude Operation; above; Every unit is run at the factory and the carburetor is set in compli-; Idle Adjustment; • Air filter is clean and properly installed.
24 CarbureTor adjusTmenT Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break- in period your engine performance will increase and exhaust emissions will stabilize. Idle speed can be adjusted as requ...
Page 25 - Fuel vapors are; extremely; flammable and may cause fire and/or explosion.; Never; test for ignition spark by ground-; roubleshooTIng
25 P ower B lower o Perator ' s M anual DangEr Fuel vapors are extremely flammable and may cause fire and/or explosion. Never test for ignition spark by ground- ing spark plug near cylinder plug hole, otherwise serious personal injury may result. T roubleshooTIng T R A H C G N I T O O H S E L B U O ...
Page 26 - Torage; times to remove remaining fuel from carburetor then
26 s Torage warning During operation the muffler or catalytic muffler and surrounding cover become hot. Always keep exhaust area clear of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may result. Long Term Storage (Over 30 Days) Do not s...
Page 27 - peCIfICaTIons; Spark arrestor muffler or spark arrestor muffler with catalyst; Premium Universal 2-Stroke Oil
27 P ower B lower o Perator ' s M anual s peCIfICaTIons MODEL ---------------------------------------------------- PB-500H, PB-500T Length PB-500H ------------------------------------------ 380mm (15.0 in.) Length PB-500T ------------------------------------------- 328mm (12.9 in.)Width PB-500H ----...
Page 28 - arranTy
28 ECHO LIMITED WARRANTY STATEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO'S RESPONSIBILITY ECHO Incorporated’s Limited Warranty, provides to the original purchaser that this ECHO product is free from defects in material and workmanship. Under normal use and maintenance from dat...
Page 31 - noTes
Page 32 - COnSUMEr PrODUCT; always; ber, Type and Serial Number of the unit with you. You can find these; Replacement Operator, Safety Manuals, and Parts Catalogs
ECHO, inCOrPOraTED 400 O akwOOd R Oad L ake Z uRich , iL 60047 www.echo-usa.com COnSUMEr PrODUCT SUPPOrT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.S.T. DEaLEr? Call 1-800-432-ECHO 1-800-432-3246 or www.echo-usa.com s ervICIng I nformaTIon parTs / serIal number Genuine ECHO Parts and ECHO REPOWER™ Parts...