350mm min
120mm
350mm
575mm
Installation and Operating Instructions
Dimplex Wall-mounted Fan Convector
08/18724/2 Issue 2
Models : WFC 3NB and WFC 3NS
Dimensions
Model(s) Specification
WFC 3NB
3kW, Switch, Thermostat & Neon - Black
WFC 3NS
3kW, Switch, Thermostat & Neon - Silver
Fig. 1
Installation
Before undertaking installation work, ensure the electricity
supply is disconnected from any relevant fixed wiring
.
Supply cable is not provided with this appliance, and a
competent electrician should therefore install it.
The appliance must be fitted horizontally with the cable or
conduit entry at bottom right. It
should be mounted such that the
underside is at least 350mm above the floor and the top of the
heater is 150mm below any overhanging shelf or obstruction.
This heater must be used on an A.C.~ supply only and the
voltage marked on the heater must correspond to the
supply voltage.
To comply with the I.E.E. Wiring Regulations, the appliance
must be earthed; the supply circuit must be adequate for the
input of the appliance, and the circuit protected by a suitable
13A fuse. A suitable termination to the fixed wiring of the
premises must be provided adjacent to the final position of the
appliance. In this instance, such a termination can be a double-
pole switch with a contact separation of at least 3mm in all
poles.
The heater must not be located immediately below a fixed
socket-outlet
.
Electrical
WARNING : THIS APPLIANCE MUST BE EARTHED.
After ensuring the electricity supply is not live, electrical
connections can be made, either to an adjacent double-pole
switch having a contact separation of at least 3mm in all poles
or to a plug-top for use in a standard 13A socket.
If the latter: Connect
Green
and Yellow
wire to
marked
E
or
plug terminal
Green
or
Green and Yellow
. Connect
Blue
wire to plug terminal marked
N
or
Black
. Connect
Brown
wire
to plug terminal marked
L
or
Red
.
Refit cover, first hooking top over the back of the unit and then
securing the bottom by refitting the two screws under the
bottom edge. The appliance is now ready for use and the
electricity supply can be reinstated.
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
.
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
.
IMPORTANT SAFETY ADVICE
WARNING – THIS APPLIANCE MUST NOT BE USED IN
A BATHROOM.
WARNING – DO NOT USE THIS HEATER IN THE
IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER
OR A SWIMMING POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED
IMMEDIATELY BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL IT IS WALL
MOUNTED CORRECTLY.
The heater carries a warning 'Do Not Cover' to alert
the user to the risk of overheating that exists if the
heater is accidentally covered.
NEVER cover or obstruct in any way the air inlet slots
at the front of the heater or the heat outlet slots in the
base of the heater.
Keep combustible materials such as drapes and other
furnishings clear from the front of the heater. Do not
use heater to dry your laundry.
This appliance is not intended for use by children or
other persons without assistance or supervision if
their physical, sensory or mental capabilities prevent
them from using it safely. Children should be
supervised to ensure that they do not play with the
appliance.
If young children, the aged, or infirm are likely to be
left in the vicinity of the heater, we advise that
adequate precautions should be taken. We
recommend that a guard be fitted to ensure contact
with the heater is avoided and objects cannot be
inserted into the product.
WARNING: In order to avoid a hazard due to
inadvertent resetting of the thermal cut-out, this
appliance must not be supplied through an external
switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the
utility.Do not use where excessive dust or moisture is
present.
For further information, please contact our guard
supplier direct on Tel. No. 01603 667957, or in the
case of difficulty or for further advice contact the
Customer Helpline.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
cable or conduit entry 350mm min. 35mm 510mm shelf 150mm min 8mm 350mm 280mm Ø10mm 6mm 575mm Fixing dimensions Procedure Release the front cover from the unit by undoing the two screws under the bottom edge. Carefully remove cover by pulling bottom-front forward, and then lift to release top from re...
Mesh Filter FilterRetaining Wires Air Inlet Grille General Cleaning WARNING : BEFORE UNDERTAKING ANY MAINTENANCE OR CLEANING WORK ON THE APPLIANCE, IMMEDIATELY DISCONNECT THE ELECTRICITY SUPPLY EITHER BY SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH OR BY REMOVING THE PLUG FROM THE SOCKET. The ou...
After Sales Service Your product is guaranteed for one year from the date of purchase. Within this period, we undertake to repair or exchange this product free of charge (excluding element & subject to availability) provided it has been installed and operated in accordance with these instruction...