Table of Contents:

  • Page 2 – Suggested Fixings; Drilling Holes; Positioning the Heater; Rear View; Operation; OPERATION - SINGLE RATED MODELS
  • Page 3 – Position O - Heating Off; IMPORTANT NOTES; e timer clock
  • Page 4 – For electrical products sold within the European Community.; After Sales Service
Loading the manual

Dimplex Low Wattage Panel Heaters
Models: DXLWP400, DXLWP400TI,

DXLWP800, DXLWP800TI N & ARLWP800TI

Installation and Operating Instructions

Dimensions

(millimetres)

Models

Specification

DXLWP400

400W Neon Heat Switch

DXLWP400TI

400W Neon Heat Switch / 24 Hour Timer

DXLWP800

800W Neon Heat Switch

DXLWP800TI N

800W Neon Heat Switch / 24 Hour Timer

ARLWP800TI

800W 2 Neon Heat Switches / 24 Hour Timer

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Electrical Connection

WARNING THIS APPLIANCE MUST BE EARTHED

If the socket outlets in your home are not of the 13 amp BS1363
type they will not accept the plug connected to this heater, therefore
cut off the plug. When cut off this plug can constitute a shock
hazard if inserted into a socket outlet. It must therefore be
disposed of safely.
Before wiring the appropriate plug please note that the wires in
this mains lead are coloured in accordance with the following
code.

GREEN/YELLOW:

EARTH

BLUE:

NEUTRAL

BROWN:

LIVE

Connect the

Green/Yellow

wire to the terminal marked

E

or the

earth symbol

or coloured

Green

or

Green/Yellow

.

Connect the

Brown

wire to the terminal marked

L

or coloured

Red

.

Connect the

Blue

wire to the terminal marked

N

or coloured

Black

.

DO NOT

connect the

Brown

(

Live

) or the

Blue

(

Neutral

) wires to

the

Earth

terminal of your 13 amp plug. If the terminals of the

plug are unmarked or you are in any doubt, consult a qualified
electrician.

CAUTION:

If you use this heater in conjunction with a thermal

control, programme controller, timer or any other device which
switches the heater on automatically observe all safety warnings
at all times.

600 mm - 400W

800 mm - 800W

500 mm

Important Safety Advice

WARNING –THIS APPLIANCE MUST NOT BE USED IN A
BATHROOM.

WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE

SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING
POOL.

WARNING – THIS HEATER MUST NOT BE LOCATED
IMMEDIATELY BELOW A FIXED SOCKET OUTLET.

The plug must be accessible after heater installation.

DO NOT USE THE HEATER UNTIL THE FEET OR WALL
BRACKETS ARE FITTED CORRECTLY.

FOLLOW these instructions carefully.

The heater carries a warning ‘DO NOT COVER’ to alert the
user to the risk of fire that exists if the heater is
accidentally covered.

Models DXLWP400TI, DXLWP800TIN and ARLWP800TI
can be set to switch on automatically. Remember to
observe all safety warnings at all times.

This appliance is not intended for use by children or other
persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.

If young children, the aged or infirm are likely to be left in
the vicinity of the heater, we advise that adequate
precautions should be taken. We recommend a guard
be fitted to ensure contact with the heater is avoided and
objects cannot be inserted into the product.

If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.

For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or
for further advice contact the Customer Helpline.

INDUKLWPRG Issue 6

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Suggested Fixings; Drilling Holes; Positioning the Heater; Rear View; Operation; OPERATION - SINGLE RATED MODELS

Installation The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3Rawlplugs, 1 Mounting Bracket and 1 Hexagon Key. Wall Mounted Operation (see Fig. 2 ) Suggested Fixings SOLID BRICK/BLOCK: No. 8 Rawlplug inserts, 6mm drill bit. PLASTERBOARD: If possible locate studding and use No. 8 woodsc...

Page 3 - Position O - Heating Off; IMPORTANT NOTES; e timer clock

Models with TimerDXLWP400TI, DXLWP800TI N & ARLWP800TI Set the I - ¡ ¡ ¡ ¡ ¡ - O sli de switch on the timer ( Fig. 3 ) to : Position O - Heating Off Position I - Manual operation This setting allows power to the heateruninterrupted by the timer settings. Theheat selector switch will control the ...

Page 4 - For electrical products sold within the European Community.; After Sales Service

Cleaning WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLYBEFORE CLEANING THE HEATER. Do not use detergents, abrasive cleaning powder or polish ofany kind on the body of the heater.Allow the heater to cool, then wipe with a dry cloth to remove dustand a damp cloth (not wet) to clean off stains. Be c...