Page 2 - Publication Date: January 2008
2 Copyright© 2004-2008 Dialogic Corporation. All Rights Reserved. You may not reproduce this document in whole or in part without permission in writing from Dialogic Corporation at the address provided below. All contents of this document are furnished for informational use only and are subject to c...
Page 3 - Contents
Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual 3 Contents Part 1: User’s Guide .......................................................................................................... 6 1 Warnings and Cautions ...........................................................................
Page 4 - Figures; Dialogic
4 Contents 7 Warnings and Cautions ............................................................................................43 8 Tools and Supplies Needed ......................................................................................47 9 Product Installation and Hot-Swap Actions ............
Page 5 - Tables; 4 Signaling Board Positions and Configurations for Dialogic; Revision History; The latest released issue of this manual can be found at:
Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual 5 16 Unlocking and Removing the DC Power Supply Module ..................................................54 17 Unlocking and Removing an AC Power Supply Module ....................................................55 18 Replacing the Hard ...
Page 7 - Chapter 1: Warnings and Cautions; Section 10.1, “Safety: Before Removing the Top Cover” on page 59; WARNING; Chapter 4, “Regulatory Specifications and Declarations”
7 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 1: Warnings and Cautions WARNING QUALIFIED SERVICE TECHNICIAN OPERATIONS:Only a qualified service technician is authorized to remove the Top Cover and to access any of the components inside the product. Before removing ...
Page 8 - IF AC POWER SUPPLIES ARE INSTALLED:; rated 125% of overall current rating of the product.
8 Chapter 1 Warnings and Cautions WARNING IF AC POWER SUPPLIES ARE INSTALLED: MAINS AC POWER DISCONNECT: The AC power cord(s) is considered the mains disconnect for the product and must be readily accessible when installed. If the individual product power cord(s) will not be readily accessible for d...
Page 9 - IF DC POWER SUPPLIES ARE INSTALLED:
9 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 WARNING IF DC POWER SUPPLIES ARE INSTALLED: ISOLATION: The product with DC input is to be installed in a Restricted Access Location in accordance with articles 110-16, 110-17 and 110-18 of the National Electric Code, ANSI/NFPA ...
Page 10 - Caution
10 Chapter 1 Warnings and Cautions Caution Anti-Static Handling Procedures: The product contains Electrostatic Sensitive Devices (ESDs), which may be permanently damaged if incorrectly handled. If modules are removed from the chassis they must be handled in accordance with appropriate anti-static ha...
Page 11 - Chapter 2: Introduction; Purpose; “International Warnings”; Products; Figure 1
11 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 2: Introduction 2.1 Purpose This manual addresses the hardware aspects of the Dialogic ® SS7G21 and SS7G22 Signaling Servers (hereinafter sometimes referred to collectively as “the SS7G21 and SS7G22 products” and indiv...
Page 12 - Power Supplies; The Power Supply Modules used in the AC-input Power Supply Cage can; not; must be specified at time of ordering, see; Server Board; Section 2.7, “SS7 Signaling Boards” on page 12; Hard Disk Drive; Number Reference”; SS7 Signaling Boards; Interface Ports” on page 36
12 Chapter 2 Introduction A list of product variants to which this manual applies can be found in Section 2.11, “Applicability” on page 14 . 2.3 Power Supplies An SS7G21 or SS7G22 product can be ordered with one of the following: • AC-input Power Supply Cage (SS7G21A, SS7G22A) • DC-input Power Suppl...
Page 13 - “Applicability” on page 14; Ethernet Ports; Related Information
13 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Depending on the variant, an SS7G21 can contain one of the following: • Up to three Dialogic ® SPCI2S boards, each providing two T1/E1 interfaces and two V.11 serial ports • Up to three Dialogic ® SPCI4 boards, each board prov...
Page 14 - Applicability; Table 1; Table 1. Product Applicability
14 Chapter 2 Introduction For more information on Dialogic ® SS7 products and solutions, visit http://www.dialogic.com/support/helpweb/signaling . 2.11 Applicability This manual applies to the Equipment Types Dialogic ® SS7G21 and SS7G22 product variants listed in Table 1 : The Product IDs shown abo...
Page 15 - Chapter 3: Product Specification; DC Power Supply Module
15 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 3: Product Specification 3.1 DC Power Supply Module The DC Power Supply Module specification is described as follows: • Input topology : Four-terminal DC input power connector for each Power Supply Module. • Connector ...
Page 16 - PCM Interface; Appendix A; Ethernet Interfaces
16 Chapter 3 Product Specification 3.4 PCM Interface The PCM interface specification is described as follows: • Ports : The number of ports depends on the product variant, which determines the type and number of SS7 Signaling Boards included. See Section 2.11, “Applicability” on page 14 for more inf...
Page 17 - Alarm Outputs; Controls and Indicators; Section 2.10, “Related Information” on page 13
17 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 3.7 Serial Port (COM2) The serial interface port specification is described as follows: • Quantity : One; mounted on the rear of the chassis. • Connector : RJ45. • Electrical : RS232. • Signals : TXD, RXD, DSR, DTR, GND. 3.8 A...
Page 18 - Information” on page 13; ID switch; Figure 4, “Back Panel Connectors and Indicators” on page 33; Visual Indicators on the Ethernet Ports; Section 6.6, “Ethernet Interfaces” on page 38; Visual Indicator on the Power Supply Module
18 Chapter 3 Product Specification alarms is given in the appropriate SS7G2x <Operating Mode> User Manual . Section 2.10, “Related Information” on page 13 lists the various user manuals. • MNR Alarm LED (amber) When lit continuously, indicates the presence of a minor fault. A minor fault is an...
Page 19 - operating mode; Product Reliability; SS7 Signaling Boards.; Table 2. Calculated Product Reliability
19 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 3.10 Physical Specifications The physical specifications of the SS7G21 and SS7G22 are described as follows: • Height : 3.45 inches (87.6 mm) • Width : 17.11 inches (434.6 mm) • Depth : 20 inches (508 mm) • Front clearance : 2 ...
Page 21 - Chapter 4: Regulatory Specifications and Declarations; Topics covered in this chapter include:; Specifications Demonstrating Compliance
21 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 4: Regulatory Specifications and Declarations Topics covered in this chapter include: • Specifications Demonstrating Compliance • Declarations of the Manufacturer or Importer • Essential Compliance Information 4.1 Spec...
Page 22 - Telecommunications Compliance
22 Chapter 4 Regulatory Specifications and Declarations 4.1.3 Telecommunications Compliance USA: TIA/EIA-IS-968 – July 2001 (SPCI, therefore SS7G21) TIA-968-A – Oct 2002 (SS7HDP, therefore SS7G22) FCC Part 68 rules as adopted by ACTA, achieved by including interface card(s) with ACTA Product-Labelin...
Page 23 - Declarations of the Manufacturer or Importer; The International Declarations of Conformity for Dialogic; Declaration of Conformity; Title; Dialogic Corporation; Authorized signature, name and function:
23 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 4.2 Declarations of the Manufacturer or Importer The International Declarations of Conformity for Dialogic ® SS7G21 and SS7G22 products are copied below, or can be downloaded from: http://www.dialogic.com/declarations/ Declara...
Page 25 - CE Declaration of Conformity – European Economic Area; The Products carry the CE mark:; Ελληνική
25 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 4.2.1 CE Declaration of Conformity – European Economic Area The Products carry the CE mark: Hereby, Dialogic Corporation, declares that the Dialogic ® SS7G21 and SS7G22 products are in compliance with the essential requirement...
Page 26 - ĺň
26 Chapter 4 Regulatory Specifications and Declarations [ Malti ] Hawnhekk, Dialogic Corporation, jiddikjara li dan SS7G21, SS7G22 jikkonforma mal-h - tig · jiet essenzjali u ma provvedimenti oh - rajn relevanti li hemm fid-Dirrettiva 1999/5/KE, 89/336/KEE, 2006/95/KE. [ Nederlands ] Hierbij verklaa...
Page 27 - Telecommunications Attachment Notice - Canada; This Class A digital apparatus complies with Canadian ICES-003.; Telecommunications Notice - Australia / New Zealand
27 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. The T1 interface provided on this equipment is...
Page 28 - and
28 Chapter 4 Regulatory Specifications and Declarations 4.3 Essential Compliance Information This section documents miscellaneous points that should be observed to ensure the proper and safe use of this product worldwide. 4.3.1 Safety Users of these products must refer to the safety information incl...
Page 29 - Section 6.4, “PCM Interface Ports” on page 35; Product Environmental Information; bringing it to the recycling collection point in your company
29 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Note that for some geographic regions, and subject to limitations, the T1/E1 ports of SS7HDP boards in SS7G22 products may be connected to “outside plant” signal conductors, and therefore become TNV-1 circuits. If your applica...
Page 31 - Chapter 5: Hardware Description; Overview
31 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 5: Hardware Description 5.1 Overview The Dialogic ® SS7G21 and SS7G22 products are equipped with a Server Board containing dual Intel Xeon processors with 512 KB L2 cache and 1 GB DRAM DIMM memory. The Server Board als...
Page 32 - Front Panel; Figure 3; Figure 3. Front Panel Controls, Indicators and Switches
32 Chapter 5 Hardware Description 5.2 Front Panel Figure 3 shows the front panel controls, indicators and switches and Table 3 summarizes their functions. Figure 3. Front Panel Controls, Indicators and Switches Table 3. Front Panel Control, Indicator and Switch Function Summary Feature Description M...
Page 33 - Back Panel; Figure 4. Back Panel Connectors and Indicators; Safety
33 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 5.3 Back Panel Figure 4 shows the back panel connectors and Table 4 summarizes their function. Figure 4. Back Panel Connectors and Indicators Table 4. Back Panel Connectors and Indicators Item Description More Informatio n ENE...
Page 34 - Rack Mounting Options; Chapter 12, “Part Number; rail; Chapter 1, “Warnings and Cautions”
34 Chapter 5 Hardware Description 5.4 Rack Mounting Options A number of optional mounting arrangements are available for the Dialogic ® SS7G21 and SS7G22 products. The mounting hardware that you order depends on your application. See Chapter 12, “Part Number Reference” for information on selecting t...
Page 35 - Chapter 6: Interfaces; DC Power Input Terminal Block; P o r t s
35 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 6: Interfaces This section provides connector pinout details for all used interface connectors on the SS7G21 and SS7G22. For locations refer to Section 5.3, “Back Panel” on page 33 . 6.1 DC Power Input Terminal Block A...
Page 36 - Table 5. PCM Interface Ports Connector Pinouts
36 Chapter 6 Interfaces Figure 6. PCM Ports on SPCI4 Boards Figure 7. PCM Ports on SS7HDP Boards The T1/E1 ports on the SS7 Signaling Boards are Safety Extra Low Voltage (SELV), that is, the apparatus connects to the outside network via Network Termination units (NT1). Use twisted-pair, screened cab...
Page 37 - Table 6
37 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Figure 8. SS7 Serial Interface Connector (Aux on SPCI2S) The SS7 serial interface ports on the SPCI2S are designated as SELV. Install the ferrite clamp(s), provided with this product, on each SS7 serial interface port cable, c...
Page 38 - Figure 9; NIC Activity LED; for more information.; Figure 9. Ethernet Interfaces Connectors
38 Chapter 6 Interfaces An SS7 Serial Interface Port Splitter Cable is available, DKL26 (see Chapter 12, “Part Number Reference” ). This is a cable that converts from the dual V.11 26-way high density D connector (detailed in Table 6 ) to two 15-way male DB15 connectors (detailed in Table 7 ). When ...
Page 39 - enabled on these products.; Table 8. Ethernet Interface Connector Pinouts
39 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 6.7 Serial Port (COM2) One serial port (COM2, marked 10101 ) is provided on the back panel. This is an RS232 port using an 8-way RJ45 connector (see Figure 10 ). The serial port can be used for configuration and management of ...
Page 40 - Alarms; The alarms port interface is a 15-way male DB15 connector (see; CAUTION; Figure 11. Alarms Connector
40 Chapter 6 Interfaces 6.8 Alarms The alarms port interface is a 15-way male DB15 connector (see Figure 11 ). This connector allows remote notification of alarm conditions. Table 10 shows the alarms connector pinouts. Each alarm (Major, Minor, Critical and Power) is the output of a SPDT relay conta...
Page 41 - Part 2: Service Technician’s Guide
41 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Part 2: Service Technician’s Guide
Page 43 - Chapter 7: Warnings and Cautions
43 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 7: Warnings and Cautions WARNING QUALIFIED SERVICE TECHNICIAN OPERATIONS:Only a qualified service technician is authorized to remove the Top Cover and to access any of the components inside the product. Before removing...
Page 47 - Chapter 8: Tools and Supplies Needed; Figure 12. Tools and Supplies Needed; Chapter 12, “Part Number Reference”
47 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 8: Tools and Supplies Needed Procedures in Part II of this manual require the following tools and supplies (see Figure 12 ): • Jumper-removal tool or needle-nosed pliers • Small flat-bladed screwdriver • Phillips (cros...
Page 49 - Chapter 9: Product Installation and Hot-Swap Actions; qualified service technician
49 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 9: Product Installation and Hot-Swap Actions This chapter describes actions that must be performed by a qualified service technician , but which do not require the removal of the Top Cover of the product. Before commen...
Page 50 - System Configuration” on page 56; Power Supply Related Actions
50 Chapter 9 Product Installation and Hot-Swap Actions — Configure the product. 10. When installation is complete and the system is operating as intended, consider if you will want to install a replacement Hard Disk Drive (HDD) in the future. If you do, now is an ideal time to perform a backup of th...
Page 51 - Replacement of Power Supply Module in AC Products; Chapter 7, “Warnings and; DC Power Supply Module, Initial Connections; for the location of the terminal block on DC Power Supply Modules.
51 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 • Replacement of Power Supply Module in AC Products The general actions required, such as (un)latching, removal and insertion of modules, are described in Section 9.2.6 . The connections are unaffected by AC Module replacement...
Page 52 - Figure 13. DC Power Supply Module Terminal Block; ) of the lug can be no larger than
52 Chapter 9 Product Installation and Hot-Swap Actions Figure 13. DC Power Supply Module Terminal Block The product is supplied with an insulating cover over the terminal block. To gain access to the terminals, apply gentle pressure to flip up the cover, while using a small flat blade screwdriver to...
Page 53 - Figure 15. DC Power Terminal Lug; Chapter 7, “Warnings and Cautions”; DC Power Supply Module, Transferring Connections; block away from the module. See; Replacing a DC Power Supply Module; Observe the following cautions:
53 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Figure 15. DC Power Terminal Lug When selecting an appropriately sized power wire, consider the power rating of the product, and the length of the cable run. When installing the product in locations other than telecommunicatio...
Page 54 - Figure 16. Unlocking and Removing the DC Power Supply Module
54 Chapter 9 Product Installation and Hot-Swap Actions Note: For DC powered products, the power source should be disconnected from any module while it is being removed or installed. When hot-swap functionality is required, ensure that one module remains installed, connected, and powered at all times...
Page 55 - Figure 17. Unlocking and Removing an AC Power Supply Module; AC power supply module shown
55 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Note: For AC powered products, the power source may be connected and turned on during Power Supply Module installation/replacement. When hot-swap functionality is required two AC power cords must be connected. Install or repla...
Page 56 - Backing up the System Configuration
56 Chapter 9 Product Installation and Hot-Swap Actions An SS7G20SHDD may be used in any SS7G2x Signaling Server, however, it requires a valid System License for that system. The process for making a backup of the System License and additional configuration files is described below. Note: Only one ha...
Page 57 - Figure 18. Replacing the Hard Disk Drive; remove the HDD carrier from the chassis.; Restoring the System Configuration
57 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Figure 18. Replacing the Hard Disk Drive 2. To unlock the carrier from the chassis, press the green tab on (horizontal) lever to the right to unlock the lever. Rotate lever 90 degrees clockwise to a vertical position, to disco...
Page 59 - Chapter 10: Working Inside the Product; Safety: Before Removing the Top Cover; DEVICES AND CABLES
59 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 10: Working Inside the Product This chapter describes actions that must be performed by a qualified service technician , and which require the removal of the Top Cover from a Dialogic ® SS7G21 or SS7G22 product. Before...
Page 60 - Removing and Installing the Top Cover; To remove the Top Cover, follow this procedure:
60 Chapter 10 Working Inside the Product 10.3 Removing and Installing the Top Cover Removal of the Top Cover is necessary when installing or removing internal components. The Top Cover does not have to be removed when installing or replacing Power Supply Modules or Hard Disk Drives (HDDs), but it mu...
Page 61 - Figure 19. Top Cover Removal and Installation; The layout of the components in the chassis of the Dialogic; Figure 20. Internal Product Layout
61 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Figure 19. Top Cover Removal and Installation 10.4 Internal Product Layout The layout of the components in the chassis of the Dialogic ® SS7G21 or SS7G22 product is shown in Figure 20 , and the components are identified in Tab...
Page 62 - Preparing SPCI Signaling Boards for Installation in SS7G21; Section 10.5, “SS7 Signaling Boards” on page 62; Table 12. Major Components in an SS7G21 and SS7G22 Chassis
62 Chapter 10 Working Inside the Product 10.5 SS7 Signaling Boards SS7G21 and SS7G22 are available with up to three SS7 Signaling Boards installed. The types of SS7 Signaling Boards that are installed depends on the model number. The procedures in Section 10.5.1 to Section 10.5.3 describe the additi...
Page 63 - Figure 21. SPCI2S and SPCI4 Board Layout; Set the ADDR switch on the SPCI Signaling Board as in; Preparing Dialogic; Use
63 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Note: If only two SPCI Signaling Boards are installed, then the middle position (No.2) should remain empty. Figure 21. SPCI2S and SPCI4 Board Layout Prepare an SPCI2S or SPCI4 Signaling Board for installation as follows: 1. Un...
Page 64 - SS7HDP Board Layout; Prepare an SS7HDP Signaling Board for installation as follows:; Installing or Replacing an SS7 Signaling Board; Product Variants” on page 63; SS7G22 Product Variants
64 Chapter 10 Working Inside the Product Note: If only two SS7HDP Signaling Boards are installed, then the middle position (No.2) should remain empty. Figure 22. Dialogic ® SS7HDP Board Layout Prepare an SS7HDP Signaling Board for installation as follows: 1. Unscrew and discard the ISA edge retainer...
Page 65 - which the SS7 Signaling Board is to be inserted. Retain the screw.; Figure 23. Installing and Replacing an SS7 Signaling Board
65 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 2. To remove the Signaling Board Subsystem, un-latch it from the chassis by placing your thumb on the rear chassis rail, and your fingers inside the recess at the rear of the Subsystem. A gentle squeeze will then lift the rear...
Page 66 - CT Bus Cable Notes; connector may be left disconnected.; Replacing the Back-up Battery
66 Chapter 10 Working Inside the Product Figure 24. Cable Tie Securing SS7 Signaling Board to Card Keep Frame CT Bus Cable Notes Note: When the CT Bus cable is installed, it is important that the two end connectors must be connected to boards. To achieve this consider the following: • For single boa...
Page 67 - ADVARSEL
67 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 To replace the back-up battery, follow this procedure: 1. Observe the Safety and ESD advice, warnings and cautions in Section 10.1 and Section 10.2 . 2. Remove the Top Cover as described in Section 10.3 , and remove the Signal...
Page 69 - Chapter 11: International Warnings; continued; SAFETY
69 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 11: International Warnings 11.1 WARNING: English continued The power supply in this product contains no user-serviceable parts. There may be more than one supply in this product. Refer servicing only to qualified perso...
Page 71 - AVERTISSEMENTS: Français; suite; CONSIGNES DE SÉCURITÉ :
71 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 11.2 AVERTISSEMENTS: Français suite Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée par l'utilisateur. Ce produit peut contenir plusieurs blocs d'alimentation. Veuillez contacter un technicie...
Page 72 - Avertissements : Français
72 Chapter 11 International Warnings Avertissements : Français (suite) Afin de permettre le refroidissement et l'aération du système, réinstallez toujours les panneaux du châssis avant de mettre le système sous tension. Le fonctionnement du système en l'absence des panneaux risque d'endommager ses p...
Page 73 - Fortsetzung; SICHERHEITSHINWEISE:
73 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 11.3 WARNUNG: Deutsch Fortsetzung Das Netzteil dieses Computers enthält keine wartungsbedürftigen Teile. Dieses Produkt kann über mehrere Netzteile verfügen. Überlassen Sie Wartungsarbeiten nur qualifizierten Fachleuten. Versu...
Page 75 - AVVERTENZA: Italiano; continua; MISURE DI SICUREZZA
75 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 11.4 AVVERTENZA: Italiano continua L'alimentatore contenuto nel computer non contiene parti riparabili dall'utente. Questo prodotto può essere fornito con più alimentatori. Per l'assistenza fare riferimento solo a personale qu...
Page 76 - Avvertenza: Italiano
76 Chapter 11 International Warnings Avvertenza: Italiano (continua) Per evitare che il sistema si surriscaldi e per garantire una ventilazione adeguata, reinstallare sempre i coperchi prima di attivare il sistema. Se si attiva il sistema senza aver riposizionato i coperchi correttamente, alcune par...
Page 77 - ADVERTENCIA: Español; continuación
77 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 11.5 ADVERTENCIA: Español continuación La fuente de alimentación de este producto no contiene piezas que puedan ser reparadas por el usuario. Puede que haya más de una fuente de alimentación en este producto. Para las reparaci...
Page 78 - Advertencia: Español
78 Chapter 11 International Warnings Advertencia: Español (continuación) Para obtener una ventilación y un flujo de aire adecuados, reinstale siempre las cubiertas de la carcasa antes de encender el sistema. Si utiliza el sistema sin las cubiertas en su lugar, puede que se dañen algunas piezas del s...
Page 79 - Chapter 12: Part Number Reference; shows the Dialogic
79 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 12: Part Number Reference Table 15 shows the Dialogic ® SS7G2x product IDs, operating mode IDs and the supported protocol module IDs. Table 16 gives the product IDs of the expansion options or spare assemblies availabl...
Page 80 - Table 16. Expansion Options or Spare Assemblies; Table 17. Accessories
80 Chapter 12 Part Number Reference Table 16. Expansion Options or Spare Assemblies Product ID Description SS7SPCI2SQ SS7 Signaling Board, 4 SS7 links, 2 E1/T1, 2 V.11 ports (use in conjunction with License Button) SS7SPCI4Q SS7 Signaling Board, 4 SS7 links, 4 E1/T1 ports (use in conjunction with a ...
Page 81 - Chapter 13: Software Licensing Information; Linux Software Distribution; file has been modified and is shown below.
81 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Chapter 13: Software Licensing Information This chapter gives important information relating to licensed software used by these products. 13.1 Linux Software Distribution This product uses a Linux software distribution. The di...
Page 83 - Connectors on the SPCI2S Signaling Board; Section 6.5, “SS7 Serial Interface Ports” on page 36; support any control lines. On; Cabling; The details and pinouts for this “Y” cable are provided in the
83 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Appendix A A.1 Connecting to V.11 (V.35-Compatible) SS7 Links This appendix discusses the issues of connecting SS7G21 product variants which include SPCI2S boards to a V.35 interface. See the Chapter 12, “Part Number Reference...
Page 85 - Clocking; The following clocking modes are currently supported:; SPCI2S/SIU Generates Clocking; generate the transmit data and clock in the received data.; SPCI2S/SIU Receiving Clock; file appropriately (this is discussed further in
85 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 A.1.3 Clocking Physically, the SPCI2S has two sets of clock pins for each serial port. These are designated “Transmit Clock” and “Receive Clock”. The “Transmit Clock” is always an output, while the “Receive Clock” is always an...
Page 87 - Glossary
87 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Glossary CT Bus A time division multiplex (TDM) bus that provides 1024, 2048, or 4096 time slots for exchanging voice, fax, or other network resources on a PCI (H.100) or CompactPCI (H.110) backplane. The Enterprise Computer T...
Page 89 - Index
89 Dialogic ® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7 Index A AC power supply module hot-swap 55 installation of 8, 50 installing a second unit 12, 50 overcurrent protection 8 power cord 8 power input 35 replacement of 51, 54 specifications 15 accessories list of 80 alarm indicat...