Please read this instruction carefully before use.

3

Switch off the power before wiring.

3

The display panel of TP02 series is waterproof. But please prevent grease, corrosive liquids and sharp objects from
contacting the TP02 series.

3

The TP02 series require 24VDC input power.

DO NOT connect input AC power supply to any of the RS-485

communication port; otherwise serious damage may occur. Check all the wiring again before switching
on the power.

3

DO NOT touch any terminal when the power is switched on. DO NOT touch any internal circuit in 1
minute after the power is switched off.

3

Make sure the groud terminal

is correctly grounded in order to prevent electromagnetic

interference.

3

Please use the fixed support

accessory which is packed together with the product provided by Delta. DO

NOT tighten the screws out of the normal torque specifications; otherwise serious damage may occur.

X

Introduction

1.1 Model

Explanation

Thank you for choosing Delta TP Series. TP02G-AS1 has the features of high resolution 160×32 dots. It provides

multilingual display and two built-in communication ports, one is for RS-232 and the other is for RS-485. RS-232

and RS-485 can be used simultaneously. Besides, it also supports communication and alarm LED indicators. The

user can purchase program copy card (optional) to copy settings and programs quickly and save download time.

™

Nameplate Explanation

M O D E L :
P O W E R IN P U T :

T P 02 G A S 1W 6 0 5 00 0 4

VX . XX

T P 02 G -A S 1
2 4V d c 3 W

DELTA E LEC TR ON ICS , IN C MAD E IN X XXXXXX

Pr od uc t i on m od el

P o w er i np ut s p ec .

Ba rc o de an d

s er i al n u mb er

Ve rs i o n

NOTE: The words of “MADE IN XXXXX” will be different due to the manufacturing location. Please refer to the actual product
for exact description.

™

Model / Serial No. Explanation

T P 0 2 G

AS 1

-

Rese rve d
Rese rve d
T: Te xt m od e
G : G r ap hic mo d e
L CD S pe c.
Se rie s n a me

TP 0 2 GA S 1 W 6 05 0 00 4

Pr od uc t i on s er i al n u mb er
Pr od uc t i on we ek s
Pr od uc t i on y ea r (2 00 6)
Pr od uc t i on p l an t

Ve rs io n
Pr od uc t i on m od el

(W : Wu ij an g ; T: Ta oy u an )

1.2 Product

Outline

D i s pl a yin g Are a

R S -2 3 2 L E D I nd i c at o r

R S -4 8 5 L E D I nd i c at o r

E s c ap e / E xit K e y

Al a rm LE D I n di c a to r

Fu n ct ion Ke y s

A r ro w Key s

E n te r K ey

1.3 Panel

Function

Explanation

PANEL COMPONENT

EXPLANATION

Alarm LED Indicator

(RED)

Status 1: When power is on, LED will blink slowly for three times.
Status 2: When there is an abnormal situation, LED will blink quickly along with
an alarm sound.

RS-232 LED Indicator

(Yellow)

LED will blink when transmits program and communicates via RS-232.

RS-485 LED Indicator

(Green)

LED will blink when communicates via RS-485.

Displaying Area

Liquid Crystal Module display area. It is used to display current program status.

PANEL COMPONENT

EXPLANATION

Escape / Exit Key

It is used to cancel an incorrect input, or to exit a programming step.

Enter Key

It is used to input a value or accept a programming command.

Arrow Keys

UP / Pg Up: It is used to increase the value or move up one page.
Pg Dn / DOWN: It is used to decrease the value or move down one page.
Left: This key is left direction key and it can be used to select the position of the
value.
Right: This key is right direction key and it can be used to select the position of
the value.

Function Keys

F0 / 0: It is used as a constant 0, or the user can define it as function F0.
F1 / 1: It is used as a constant 1, or the user can define it as function F1.
F2 / 2: It is used as a constant 2, or the user can define it as function F2.
F3 / 3: It is used as a constant 3, or the user can define it as function F3.
F4 / 4: It is used as a constant 4, or the user can define it as function F4.
F5 / 5: It is used as a constant 5, or the user can define it as function F5.
F6 / 6: It is used as a constant 6, or the user can define it as function F6.
F7 / 7: It is used as a constant 7, or the user can define it as function F7.
F8 / 8: It is used as a constant 8, or the user can define it as function F8.
F9 / 9: It is used as a constant 9, or the user can define it as function F9.

1.4 Back

Panel

RS-23 2

Extens io n p ort

5 PIN terminal / Wire gauge: 12-24 AWG / Torque: 4.5 lb.-inch

1.5 Dimension

Front panel (unit: mm [inch])

Right side diagram (unit: mm [inch])

Back panel

Mounting dimension (unit: mm [inch])

Thickness Range 0.5~9mm

135~136.5[5.31~5.37]

85

[3.35]

Vertical view (Unit: mm)

1.6 Installation

Please insert TP02 series to the opening hole of panel and tighten the screws. However, if a firm mounting TP02

series to the panel is needed, please use the mounting fixed support accessory which is packed together with TP02

series, then insert the fixed support in the back and tighten the screws.

If the fixed support is not installed well, Delta will not guarantee the waterproof function. The screw torque

should be 4-5(kg-cm). DO NOT exceed this specification when tightening the screws; otherwise TP02 series may be

damaged. Please leave sufficient space (more than 50mm) around the unit for heat dissipation.

Do not install and mount TP02 series in the following environment.

h

A location subjected to Airborne dust, metallic particles, oil and smoke, corrosive or

flammable gases and liquids.

h

A location where temperature and humidity will exceed specifications.

h

A location where vibration and shock will exceed specifications.

™

The flat surface should be a UL Type 4 "Indoor Use Only" enclosure or equivalent (IP65 / NEMA4). Please
refer to the figures below.

Thi ckn ess : 0 .5~9 .0m m

Y

Function Specifications

ITEM

TP02G-AS1

Screen Type

STN-LCD

Display Color

Monochromatic

Backlight

The back-light automatic turn off time is 1 ~ 99 minutes (0 = do not turn off)

(The back-light life is about 50 thousand hours at 25°C)

Resolution

160 x 32 dots

Display Range

(W) x (H) = 72 x 22 (unit: mm)

Contrast Adjustment

15 levels of adjustment

Language / Font

ASCII: Alphanumeric (including European characters)

Taiwan: (Big 5 codes) Traditional Chinese Fonts

China: (GB2324-80 codes) Simplified Chinese Fonts

Font Size

ASCII: 5 × 8, 8 × 8, 8 × 12, 8 × 16

Alarm LED Indicator (RED)

1. Power on indication (Blink for three times)
2. Communication error alarm
3. Special indication by user programming

RS-232 LED Indicator

(Yellow)

It will blink when transmitting program and communicating by using RS-232.

RS-485 LED Indicator

(Green)

It will blink when communicating by using RS-485.

Program Memory

256KB flash memory

Serial Communication Port

RS-232 (COM1)

Unsynchronized transmission method: RS-232

Data length: 7 or 8 bits, Stop bits: 1 or 2 bits

Parity: None/Odd/Even, Transmission speed: 4,800bps ~115,200bps

RS-232: 9 PIN D-SUB male

Extension Communication

Port

RS-485 (COM2)

Unsynchronized transmission method: RS-485

Data length: 7 or 8 bits, Stop bits: 1 or 2 bits

Parity: None/Odd/Even, Transmission speed: 4,800bps ~115,200bps

RS-485: 5 PIN removal terminal

Extension Interface

1. Update firmware version
2. The slot for program copy card

Battery Cover

DC 3V battery for HMI

5 PIN Removal Terminal

Include DC 24V input and RS-485 communication input





ht tp: //w ww. del ta .c om .tw /ind us tr i al au toma ti on /

Terminal Panels Series

!

Instruction Sheet

Warning

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Delta Models