1.Tolerance of inductance
1.5~330uH 30%
2. Irated is the DC current which cause the inductance drop less than 35% of its nominal inductance without current
o
and the surface temperature of the part increase less than 45 C.
o
o
3. Operating temperature: -20 C to 105 C (including self-temperature rise).
L DCR
PART NO.
(uH)
( ) MAX
(Adc)
SIL104 - 1R5
1.5
0.0081
10.0
SIL104 - 2R5
2.5
0.0100
7.5
SIL104 - 3R8
3.8
0.0130
6.0
SIL104 - 5R2 5.2
0.0220
5.5
SIL104 - 7R0
7.0
0.0270
4.8
SIL104 - 100
10
0.0350
4.4
SIL104 - 150
15
0.0500
3.6
SIL104 - 220
22
0.0730
2.9
SIL104 - 330
33
0.0930
2.3
SIL104 - 470
47
0.1280
2.1
SIL104 - 680
68
0.2130
1.5
SIL104 - 101
100
0.3040
1.35
SIL104 - 151
150
0.5060
1.15
SIL104 - 221
220
0.7560
0.92
SIL104 - 331
330
1.0900
0.70
DELTA ELECTRONICS, INC.
(TAOYUAN PLANT CPBG)
SMT Power Inductor
S I L 1 0 4 Ty p e
R o H S c o m p l i a n t .
L o w p r o f i l e ( 4 . 0 m m m a x . h e i g h t ) S M D t y p e .
M a g n e t i c a l l y s h i e l d e d , s u i t a b l e f o r h i g h d e n s i t y m o u n t i n g .
H i g h e n e r g y s t o r a g e a n d l o w D C R .
P r o v i d e d w i t h e m b o s s e d c a r r i e r t a p e p a c k i n g .
I d e a l f o r p o w e r s o u r c e c i r c u i t s , D C - D C c o n v e r t e r ,
D C - A C i n v e r t e r s i n d u c t o r a p p l i c a t i o n .
I n a d d i t i o n t o t h e s t a n d a r d v e r s i o n s s h o w n h e r e ,
c u s t o m i n d u c t o r s a r e a v a i l a b l e t o m e e t y o u r e x a c t r e q u i r e m e n t s .
Features
10.8
2.5
C
D
B
A
10.8
4 1
Electrical Characteristics:
0.00
0.01
0.10
1.00
10.00
100.00
CURRENT (A)
1.00
10.00
100.00
IN
D
U
C
T
A
N
C
E
(u
H
)
100
120
150.
180
220
270
330
470
560
680
820
101
390
121
151
181
221
271
331
7R0
5R2
3R8
2R5
1R5
Mechanical Dimension:
Unit: mm
252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com
I
R A T E D
2
1
RECOMMENDED PAD PATTERNS
C = 4 . 0 / 0 . 1 5 7 M a x .
U N I T : m m / i n c h
A = 1 0 . 0 0 . 3 / 0 . 3 9 4 0 . 1 1 2
B = 1 0 . 0 0 . 3 / 0 . 3 9 4 0 . 1 1 2
D = 3 . 0 0 . 1 / 0 . 11 8 0 . 0 0 4
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.