INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN / LIGHT / NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1.
Make sure that the electric service supply voltage is AC
120V, 60Hz.
2.
Follow all local electrical and safety codes, as well as the
National Electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA).
3.
Always disconnect the power source before working on
or near the ventilating fan, motor or junction box.
4.
Protect the power cord from sharp edges, oil, grease, hot
surfaces, chemicals or other objects.
5.
Do not kink the power cord.
6.
Do not install the unit where ducts are configured as
shown in Fig. A.
7.
Provide suction parts with proper ventilation.
8.
This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9.
These ventilating fans are intended for residential usage
only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
2.
Before servicing or cleaning the unit, switch the power
off on the service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
4.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) and local code authorities.
5.
When cutting or drilling into the wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
If this unit will be installed over a tub or shower, it must
be marked as appropriate for the application and be
connected to a GFCI (Ground Fault Circuit Interrupter) –
protected branch circuit.
8.
Do not use this unit with any other solid-state control
devices. Solid-state control devices may cause harmonic
distortion, which can cause a motor humming noise.
9.
NEVER place a switch where it can be reached from a tub
or shower.
10.
Turning angle too large
Duct shrink
y
d
o
b
e
h
t
r
a
e
n
w
o
b
l
E
s
w
o
b
l
e
y
n
a
m
o
o
T
Body
Fig. A
CAUTION
1.
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2.
Not for use in cooking areas. (Fig. B)
3.
This product must properly connect to the grounding
conductor of the supply circuit.
4.
To reduce the risk of injury to persons, install the fan at
least 7 feet (2.1m) above the floor.
45
°
Cooking area
45
°
Do not install above or
inside this area
Cooking
Equipment
floor
Fig. B
Not to be installed in a ceiling thermally insulated to a value
greater than R40. (This is required for installation in Canada
only).
MODELS SIG
80
/ SIG
80
M / SIG
110
/ SIG
110
D / SIG
110
H
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2. MODELS SIG 80 / SIG 80 M / SIG 110 / SIG 110 D / SIG 110 H SUPPLIED ACCESSORIES Part name Appearance Quantity Grille 1 1 Tapping Screw (ψ 4x25) 4 Screw #8- 32x1/4” 4 Duct connector 1 Duct Screw (M4x12) 1 Suspension bracket I 13” (318.5 ) 2 Suspension bracket II (318.5 ) 2 Inches (mm) INSTALL...
Page 3. MODELS SIG 80 / SIG 80 M / SIG 110 / SIG 110 D / SIG 110 H 3. Connect wiring 3-1. Follow all local electrical and safety codes 3-2. NEVER place a switch where it can be reached from a tub or shower 3-3. Connect wires as shown in wiring diagrams. Single Speed Models: SIG80, SIG110 Motion Mode...
Page 4. MODELS SIG 80 / SIG 80 M / SIG 110 / SIG 110 D / SIG 110 H Motion Model: SIG80M Factory setting: low speed airflow 40CFM, time delay 15 minutes. Humidity Model: SIG110H DIMENSION 5-2. Motion control mode: Turn the POWER switch on to operate at motion control mode. When motion is detected, th...