Delta SFB0212H - Manual

Delta SFB0212H

Delta SFB0212H – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.

Operating

Voltage

Range

MODEL

Rated

Voltage

Maximum

Air Flow

Speed

Maximum

Air Pressure

Noise

PART

NO. FUNCTION VDC VDC Amp Watt R.P.M.

CFM mmH

2

O IN H

2

O dB-A

125 x 38 x 45 MM SERIES

SFB

DIMENSIONS DRAWING

P & Q CURVE

(AT RATED VOLTAGE)

MOUNTING PANEL CUTOUT

mm

(INCH)

UNIT:

OUTLET SIDE

INLET SIDE

44.0(2X)

(1.732(2X))

9

.9

(0

.3

9

0

)

(4.724)

120.0

(1

.0

1

2

)

2

5

.7

(0.433)

11.0

*

Weight : 110g (3.88 OZ)

*

Lead Wires :

*

Material

*

Bearing Type

Ball Bearings

Red Wire Positive(+)

UL 1007 AWG #24 OR Equivalent

Black Wire Negative(-)

Impeller & Frame : Plastic(UL 94V-0)

SFB0212L

-R00 / -F00

12

5.5 to 13.8

0.22

2.64

3600

0.312

11.02

3.79

0.149

33.0

SFB0212M

-R00 / -F00

12

5.5 to 13.8

0.36

4.32

5000

0.462

16.32

8.24

0.324

44.5

SFB0212H

-R00 / -F00

12

5.5 to 13.8

0.42

5.04

6400

0.614

21.68

14.78

0.582

48.0

SFB0212HH

-R00 / -F00

12

5.5 to 13.8

0.62

7.44

7000

0.655

23.13

16.32

0.643

52.0

136

mm

(INCH)

UNIT:

SFB0212X

0.2

4.0

0.16

0

0

0

0

12.0

0.32

0.48

8.0

0.4

0.6

L

M

H

20.0

16.0

0.64

0.80

7.5

29.5

15.0

(m

m

H

O

)

(I

N

H

O

)

2

2

(M /MIN)

(CFM)

3

A

ir

P

re

s

s

u

re

Air Flow

0.8

1.0

22.5

24.0

0.96

HH

http://www.deltaww.com

Input

Power

Input

Current