Page 3 - Modbus TCP Remote I/O Communication Module RTU-EN01; DVP-PLC Operation Manual; Introduction; touch any terminal when the power is switched on.; Table of Content
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 1 Introduction 3 This operation manual only provides introductory information on electrical specification, installation and wiring. 3 RTU-EN01 is an OPEN-TYPE device and therefore should be installed in an enclosure free of...
Page 5 - Introduction
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 3 1 Introduction To ensure correct installation and operation of RTU-EN01, please read this manual carefully before using your RTU-EN01. RTU-EN01is an Ethernet remote I/O module for remote setting through Delta’s DCISoft. R...
Page 6 - Product Profile & Outline
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 4 Environment Noise immunity ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line:±2KV, Digital Input: ±2KV, Communication I/O: ±2KV RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 100...
Page 8 - ST OP; Installation & Wiring
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 6 2.4 RUN/STOP Switch Status Explanation 1. RUN indicator on RTU-EN01 is ON. 2. Analog input/output module is in RUN status. RUN 3. Smart PLC function is running. 1. Analog input/output module switches from RUN to STOP stat...
Page 9 - Use standard 35mm DIN rail.
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 7 D V P -1 6 S P D V P -0 2 D A D V P -1 6 S P D V P -0 2 D A P O W E R R U N B AT. L O W R U N S TO P R T U -E N 0 1 L A N R S -2 3 2 R S -4 8 5 3.2 Installing RTU-EN01 and DVP Slim Series Digital Input/Output Module onto ...
Page 11 - Explanations on BR
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 9 BR# Attribute Content Explanation Default Latched 24 R ID of the 1st analog I/O module ID of the 1st analog I/O module NO 25 R ID of the 2nd analog I/O module ID of the 2nd analog I/O module NO 26 R ID of the 3rd analog I...
Page 12 - B R # 5 : C O M 2 C o m m u n i c a t i o n S e t t i n g s
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 10 B R # 5 : C O M 2 C o m m u n i c a t i o n S e t t i n g s Explanations: b0 ~ b3 Interface Explanation Data Baud rate (bps) Data Baud rate (bps) Data Baud rate (bps) 0x1 110 0x6 2,400 0xB 57,600 0x2 150 0x7 4,800 0xC 11...
Page 13 - B R # 2 3 : N u m b e r o f A n a l o g I / O M o d u l e s; A n a l o g I / O M o d u l e; Read the ID of the 1
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 11 Code Indication How to correct F0 Returning to default setting -- F1 RTU-EN01 being powered -- F2 Power supply in low voltage Check if the power supply of the module works normally. F3 Internal error. Manufacturing error...
Page 15 - R C R # 0 ~ # 3 9 9 : C o n t r o l R e g i s t e r f o r R i g h t - S i d e A n a l o g I / O M o d u l e s
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 13 RCR# Attribute Content Explanation Default Latched 200 ~ 249 R/W The 5 th analog I/O module Control register for the 5 th analog I/O module -- NO 250 ~ 299 R/W The 6 th analog I/O module Control register for the 6 th ana...
Page 17 - Modbus; Function Codes Supported
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 15 R# Attribute Content Explanation Default Latched 6 R/W RTC 6 Real-time clock OFF NO 7 R/W RTC 7 Real-time clock OFF NO 8 R/W RTC 8 Real-time clock OFF NO 9 R/W RTC 9 Real-time clock OFF NO 10 R/W RTC 10 Real-time clock O...
Page 18 - Discrete input; Setting up Software; Broadcast
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 16 5.3 Device Type & Device Address Discrete input Device type Modbus address (Hex) 6-digit Modbus address (Dec) Number RX 0x0400 ~ 0x04FF 101025 ~ 101280 256 Coil RY 0x0500 ~ 0x05FF 001281 ~ 001537 256 T 0x1600 ~ 0x160...
Page 20 - IP
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 18 3. Double-click on the module to be set up to enter the setup page. The first page overviews the basic status of the module and information on the right-side module. 4. The next page is for basic network setup. Consult y...
Page 23 - Network Settings; Setting up static IP of the PC
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 21 the communication. The IP of the gateway has to be in the same subnet as RTU-EN01. The default gateway of RTU-EN01 is 192.168.1.1. 3. Timer setting: For setting up TCP connection idle time, Modbus time-out and minimum de...
Page 24 - Setting up Time Server; Setup
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 22 4. Enter “192.168.0.2” into IP address. Click “OK” to complete the IP address setting of the PC. 6.5 Setting up Time Server RTU-EN01 offers real-time clock (RTC) functions. You can set up your own time for RTU-EN01 or up...
Page 27 - Smart PLC Setting – Counter; Counter
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 25 You can move the IF-THEN setting upwards or downwards to change the execution order of them. 6.8 Smart PLC Setting: Timer RTU-EN01 has the independent Smart PLC function. The timer is able to time following the system ti...
Page 28 - Smart PLC Setting – RTC; RTC
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 26 1. Enable: Decide whether to enable the counter in this column. 2. Count up/count down: Decide whether the counter will be counting up or counting down. 3. Up bound/low bound: The upper bound and lower bound of the count...
Page 32 - Setting up Gateway; Gateway setup page
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 30 T#0 ~ T#15, total 16 bits and 16 registers. C#0 ~ C#15, total 16 bits and 16 registers. R#0 ~ R#15, total 16 bits and 16 registers. RCR#0 ~ RCR#399, total 400 registers. BR#0 ~ BR#63, total 64 registers. 3. Format: Selec...
Page 37 - Security Setting
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 35 6.15 Security Setting To prevent the set values in RTU-EN01 from being modified, you can set up passwords to lock the settings in RTU-EN01. Setting up password 1. Login: Log in to check and modify parameters. 2. Passwo...
Page 38 - Returning to Default Settings
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 36 However, if you set up RTU-EN01 by RS-232, you can return the setting to default one whether the password is locked or not. For example, if you have locked RTU-EN01 but forget the password, you have to return RTU-EN01 to...
Page 44 - Application Examples – DCISoft; Steps; Open the setup page and switch to “Smart PLC” page.
Modbus TCP Remote I/O Communication Module RTU-EN01 DVP-PLC Operation Manual 42 7 Application Examples – DCISoft 7.15 Smart PLC: IF-THEN Application Setting up IF-THEN in Smart PLC functions by using DCISoft. Steps 1. When RX#0 and RX#1 are ON, set RY0 to output. 2. When RX#2 turns from OFF to ON, s...