  • Page 2 – TECHNICAL SPECIFICATIONS; PARAMETER; NOTES and CONDITIONS
  • Page 3 – ELECTRICAL CHARACTERISTICS CURVES; maximum input voltage at 25°C.
  • Page 4 – Output voltage response to step-change in load; Typical input characteristics at room temperature
  • Page 5 – Figure
  • Page 6 – Copper Strip
  • Page 7 – DESIGN CONSIDERATIONS; Input Source Impedance
  • Page 8 – FEATURES DESCRIPTIONS; Over-Voltage Protection; Remote on/off implementation; Resistance; Effective circuit configuration for remote sense
  • Page 9 – Circuit configuration for trim-up (increase output; Vo; Trim UP resistor selection
  • Page 10 – THERMAL CONSIDERATIONS; Thermal Testing Setup; Wind tunnel test setup; THERMAL CURVES; Temperature measurement location; Output current vs. ambient temperature and air
  • Page 11 – Function
  • Page 14 – PART NUMBERING SYSTEM; MODEL LIST; MODEL NAME
Loading the manual

1

FEATURES

Š

High efficiency: 92.5 % @12V/18A

Š

Size: 57.9x36.8x10.8mm (2.28”x1.45”x0.43”)

(w/o heatspreader)

57.9x36.8x12.7mm (2.28”x1.45”x0.50”)
(with heatspreader)

Š

Industry standard pin out

Š

Fixed

frequency

operation

Š

Fully protected: OTP, OVP, OCP, UVLO

Š

No minimum load required

Š

Wide output trim range: -20~+10%

Š

Remote sense

Š

Fast transient response

Š

Basic insulation and 2250V isolation

Š

ISO 9001, TL 9000, ISO 14001, QS9000,

OHSAS18001 certified manufacturing facility

Š

UL/cUL 60950-1 (US & Canada) recognized,

TUV (EN60950-1) certified

Š

CE mark meets 73/23/EEC and 93/68/EEC

directives

OPTIONS

Š

Latched over current protection

Š

Positive remote on/off

Š

Short lead lengths


APPLICATIONS

Š

Telecom/DataCom

Š

Wireless

Networks

Š

Optical

Network

Equipment

Š

Server and Data Storage

Š

Industrial/Test

Equipment

Delphi Series Q48SP, 216W Quarter Brick Family
DC/DC Power Modules: 48V in, 12V/18A out


The Delphi Series Q48SP Quarter Brick, 48V input, 12V single output,
isolated, DC/DC converters are the latest offering from a world leader in
power systems technology and manufacturing

Delta Electronics, Inc.

This product family provides up to 216 watts of power or up to 18A of
output current in an industry standard footprint. With creative design
technology and optimization of component placement, these converters
possess outstanding electrical and thermal performance, as well as
extremely high reliability under highly stressful operating conditions.

All

models are fully protected from abnormal input/output voltage, current,
and temperature conditions. The Q48SP Delphi Series converters meet all
safety requirements with basic insulation.

DATASHEET
DS_Q48SP12017_05302008

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL SPECIFICATIONS; PARAMETER; NOTES and CONDITIONS

DS_Q48SP12017_05302008 2 TECHNICAL SPECIFICATIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal Vout unless otherwise noted; mounted on board.) PARAMETER NOTES and CONDITIONS Q48SP12017NRFA Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous -0.5 80 Vdc Transient (100ms, ...

Page 3 - ELECTRICAL CHARACTERISTICS CURVES; maximum input voltage at 25°C.

DS_Q48SP12017_05302008 3 ELECTRICAL CHARACTERISTICS CURVES 70 72 74 76 78 80 82 84 86 88 90 92 94 2 4 6 8 10 12 14 16 18 OUTPUT CURRENT(A) E F F ICI E N CY (% ) 36V 48V 75V 0 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 OUTPUT CURRENT(A) LO S S( W ) 36V 48V 75V Figure 1: Efficiency vs. load curr...

Page 4 - Output voltage response to step-change in load; Typical input characteristics at room temperature

DS_Q48SP12017_05302008 4 ELECTRICAL CHARACTERISTICS CURVES Figure 5: Output voltage response to step-change in load current (50%-75% of Io, max: di/dt =0.1A/µs). Load cap:1µF ceramic capacitor and 10uF Tantalum capacitor. Top Trace: Vout (200mV/div), Bottom Trace: Iout (5A/div). Scope measurement sh...