Delta PG-05 - Manual
Delta PG-05 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
2 0 0 7 -0 7 - 1 6
5 0 11 6 2 6 8 0 2 -G 5 E 2
PG-05
Pulse Generator Card for VFD-V Series
Instruction Sheet
1-1 PG-05 Appearance
1-2 Explanations of the Terminals of PG-05 Card
Terminals Explanation
VP
Output voltage of encoder: +5V
±
5% 200mA
DCM
Common point of the power supply and the signal
A 1 ,
B 1 ,
Z 1 ,
A 1
B 1
Z 1
The input signal of encoder (select output type of the encoder
from FJP1).
The power supply can be single-phase or 2-phase. It can be
up to 500KP/Sec (max.).
A 2 ,
B 2 ,
A 2
B 2
Pulse (hand wheel and PLC) input (select input type from
FJP4).
The power supply can be single-phase or 2-phase. It can be
up to 500KP/Sec (max.).
A O,
BO,
Z O,
A O
BO
Z O
The output signal of encoder can set the dividing frequency by
using parameter 10-20.
The Max. output of Line drive is 50mA.
1-3 Wiring Examples
Wiring Diagram 1
MPG
FWD
RE V
MI1
MI2
MI3
MI4
MI6
MI5
DCM
24V
FWD/STOP
REV/STOP
Multi-step2
Multi-step3
Multi-step4
Di gi tal common
R/L1
S/L2
T/L3
Non- Fuse br eaker
NFB
R
S
T
+1 +2/B1 B2
U/T1
V/T2
W/T3
M
3~
Braking Resis tor(Optio n)
Motor
M
u
lt
i-f
u
n
ct
io
n
inp
u
t
te
rm
in
a
ls
F
a
ct
or
y D
e
fa
ul
t
Jumper
Reset
E.F.
-
U
W
V
VP
DCM
A1
A1
B1
B1
Z1
Z1
PG
VP
DCM
A2
A2
B2
B2
Multi-step1
Incremental encoder
Line driver
Line driver
Main circuit (power ) ter minals
Contr ol circuit terminals
Shielded l eads & Cable
10-08
10-12
Hand wheel
AO
BO
ZO
AO
BO
ZO
Wiring Diagram 2
FWD
REV
Mi1
Mi2
Mi3
Mi4
Mi6
Mi5
DCM
24V
FWD/ STOP
REV/STOP
Multi-step2
Multi -step3
Multi-step4
Di gi tal common
R/L1
S/L2
T/L3
Non- Fuse br eaker
NFB
R
S
T
+1 +2/B1 B2
U/T1
V/T2
W/T3
M
3~
Braking Resis tor(Opt ion)
Motor
M
u
lti-
fu
nc
tio
n i
n
pu
t t
e
rm
in
al
s
Fa
c
to
ry
De
fa
u
lt
J umper
Reset
E.F.
-
U
W
V
VP
DCM
A1
A1
B1
B1
Z1
Z1
PG
DCM
A2
A2
B2
B2
Multi -step1
Incremental encoder
Line driver
Main ci rcuit (power ) ter minals
Contr ol circui t terminal s
Shielded l eads & Cable
EH- PLC
Y0
Y0
Y1
Y1
Y0
Y0
Y1
Y1
P hase d iff erence
90
o
COM
AO
BO
ZO
AO
BO
ZO
1-4 Wiring Notes
1. Using the shielded wire to prevent interference, and do not line up in
parallel with circuits of AC200V or above.
2. Recommended wire size: 0.21~0.81mm
2
(AWG24~AWG18).
3. Wire length (It is inversely proportional with signal frequency).
The Output Types
of the Encoder
Max. Wire
Length
Wire Gauge
Voltage 50m
Open Collector
50m
1.25mm
2
(AWG18) or above
Line Driver
300m
Complementary 70m
1.25mm
2
(AWG18) or above
1-5 Installation
For 1-5HP
For 7.5 HP and above
Step 1: Insert 3 PCB supports into control board.
Step 2: Press the PG card on the control board to be fixed to tighten the 3
screws with a torque of 4-6kgf-cm. If the PG card is not fixed on
the control board, it may cause screw idle running and cannot turn
the screw into supports.
1-6 The Corresponding Output Types of Encoder
Output Types of the
Encoder
FJP1 FJP2
V
o
lt
age
O/P
0V
VCC
oc
T P
oc
T P
Open
Collector
O/P
0V
VCC
oc
T P
oc
T P
Line
Driver
Q
Q
oc
T P
oc
T P
Compl
ement
ary
O/P
0V
VCC
oc
T P
oc
T P
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.