Delta ND Series - Manual

Delta ND Series

Delta ND Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – TECHNICAL SPECIFICATIONS; PARAMETER; Units
  • Page 3 – ELECTRICAL CHARACTERISTICS CURVES; Converter efficiency vs. output current
  • Page 7 – DESIGN CONSIDERATIONS; the signal is driven; Safety Considerations; It is recommended that the user to provide a fuse with; in the input line for safety. The output voltage; Enable Input drive circuit for ND series
  • Page 8 – circuit configuration for remote sense; Output Voltage Programming; Trimming Output Voltage; Output Voltage; Typical trim resistor values
  • Page 9 – Output Capacitance; the Trim pin to the Ground for margining; Circuit configuration for output voltage margining; Reflected Ripple Current and Output Ripple and; Input reflected ripple/ capacitor ripple current and; To use voltage trim, the trim equation for the ND50 is; Vout is the desired output voltage; Power Good
  • Page 10 – THERMAL CUREVES; Temperature measurement location* The allowed; Output current vs. ambient temperature and air; THERMAL CONSIDERATION; Thermal Testing Setup; Wind tunnel test setup figure dimensions are in
  • Page 12 – WARRANTY
Loading the manual

PRELIMINARY DATASHEET
DS_ND12S50A_07172008

FEATURES

Š

High

efficiency:

92.5% @ 12Vin, 3.3V/50A out

y

Size: 61.0x31.8x10.2mm

(2.40”×1.25”×0.40”)

Š

Voltage and resistor-based trim

Š

No minimum load required

Š

Output voltage programmable from

0.9Vdc to 3.63Vdc via external resistors

Š

Fixed

frequency

operation

Š

Single-in line package (SIP)

Š

Input UVLO, output OCP, OTP, SCP

Š

Remote

ON/OFF

(Positive)

Š

Power good output signal (open collector)

Š

Output voltage sense

Š

ISO 9001, TL 9000, ISO 14001, QS9000,

OHSAS18001 certified manufacturing facility

Š

UL/cUL 60950-1 (US & Canada), TUV

(EN60950-1) - pending


APPLICATIONS

Š

DataCom

Š

Distributed power architectures

Š

Servers

and

workstations

Š

LAN / WAN applications

Š

Data processing applications

OPTION

Š

Negative on/off logic

Š

Current

sharing

Delphi ND Series Non-Isolated Point of Load
DC/DC Power Modules: 12Vin, 0.9V~3.63Vout,
50Aout


The Delphi ND Series, 12V input, single output, non-isolated point of
load (POL) DC/DC converters are the latest offering from a world leader
in power systems technology and manufacturing — Delta Electronics,
Inc. The ND/NE product family is the second generation, non-isolated
point-of-load DC/DC power modules for the DataCom / Networking / IT
Applications and it will help to cut the module size by 35% to 50%
compared to the first generation NC series POL modules. The ND/NE
product family provides 6A to 60A of output current in a vertically or
horizontally mounted through-hole package and the output can be
resistor trimmed from 0.9Vdc to 3.63Vdc. It provides a very cost
effective, high efficiency, and high density point of load solution. With
creative design technology and optimization of component placement,
these converters possess outstanding electrical and thermal
performance, as well as extremely high reliability under highly stressful
operating conditions.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL SPECIFICATIONS; PARAMETER; Units

DS_ND12S10A_07172008 2 TECHNICAL SPECIFICATIONS (Ambient Temperature=25°C, minimum airflow=200LFM, nominal V in =12Vdc unless otherwise specified.) PARAMETER NOTES and CONDITIONS ND12S0A0V50 (Standard) Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage -0.3 13.8 Vdc Operating Temperature Re...

Page 3 - ELECTRICAL CHARACTERISTICS CURVES; Converter efficiency vs. output current

DS_ND12S10A_07172008 3 ELECTRICAL CHARACTERISTICS CURVES 70 75 80 85 90 95 5.01 10 15 20 25 30 35 40 45 50 OUTPUT CURRENT (A) EF F ICI ENCY ( % ) 1 0 . 2 1 2 . 0 1 3 . 8 70 75 80 85 90 95 5.01 10 15 20 25 30 35 40 45 50 OUTPUT CURRENT (A) EF F ICI ENCY ( % ) 1 0 . 2 1 2 . 0 1 3 . 8 Figure 1: Convert...

Page 7 - DESIGN CONSIDERATIONS; the signal is driven; Safety Considerations; It is recommended that the user to provide a fuse with; in the input line for safety. The output voltage; Enable Input drive circuit for ND series

DS_ND12S10A_07172008 7 DESIGN CONSIDERATIONS The ND 50A uses two phase and voltage mode controlled buck topology. The output can be trimmed in the range of 0.9Vdc to 3.63Vdc with a resistor from Trim pin to Ground. A remote sense function is provided and it is able to compensate for a drop from the ...

Other Delta Models