Delta NC15 Series - Manual

Delta NC15 Series

Delta NC15 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – TECHNICAL SPECIFICATIONS; PARAMETER
  • Page 3 – ELECTRICAL CHARACTERISTICS CURVES; Converter efficiency vs. output current
  • Page 6 – Typical transient response to step load change at
  • Page 7 – DESIGN CONSIDERATIONS; disabled when; Block Diagram
  • Page 8 – Rs values should not be less than 280; Over-Current and Short-Circuit Protection; Output Voltage; OPEN; Output Voltage Programming; Output voltage trim with voltage source; Rt is the resistor to be defined with the trim voltage (in K; Trimming Output Voltage; Example
  • Page 9 – This output pin uses positive logic and is; Current Sink Capability; the Trim pin to the Ground for for margining; Input reflected ripple/ capacitor ripple current and; Paralleling
  • Page 10 – THERMAL CONSIDERATION; Thermal Testing Setup
  • Page 13 – MECHANICAL DRAWING; VERTICAL HORIZONTAL
  • Page 14 – WARRANTY
Loading the manual

FEATURES

High Efficiency:

91% @ 12Vin, 5V/15A out

Size: 30.5x27.9x11.4mm

(1.20”×1.10”×0.45”) -- Vertical

30.5x27.9x12.9mm

(1.20”×1.10”×0.51”) -- Horizontal

Voltage and resistor-based trim

No minimum load required

Output voltage programmable from

0.9Vdc to 5.0Vdc via external resistors

Fixed frequency operation

Input UVLO, output OCP, SCP

Power good output signal

Remote ON/OFF (default: Positive)

ISO 9000, TL 9000, ISO 14001 certified

manufacturing facility

UL/cUL 60950-1 (US & Canada)

Recognized, and TUV (EN60950-1)

Certified

CE mark meets 73/23/EEC and 93/68/EEC

directives

APPLICATIONS

Delphi NC15 Series Non-Isolated Point of Load
DC/DC Power Modules: 12Vin, 0.9V-5.0Vout, 15A

The Delphi NC15 Series, 12V input, single output, non-isolated point of
load DC/DC converters are the latest offering from a world leader in
power systems technology and manufacturing

Delta Electronics, Inc.

The NC15 series operates from a 12V nominal input, provides up to 15A
of power in a vertical or horizontal mounted through-hole package and
the output can be resistor- or voltage-trimmed from 0.9Vdc to 5.0Vdc. It
provides a very cost effective point of load solution. With creative design
technology and optimization of component placement, these converters
possess outstanding electrical and thermal performance, as well as
extremely high reliability under highly stressful operating conditions.

DATASHEET
DS_NC12S15A_01102008

DataCom

Distributed power architectures

Servers and workstations

LAN / WAN applications

Data processing applications

OPTIONS

Vertical or horizontal versions

Negative ON/OFF logic

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL SPECIFICATIONS; PARAMETER

NC12S15A_01102008 2 TECHNICAL SPECIFICATIONS (Ambient Temperature=25°C, minimum airflow=200LFM, nominal V in =12Vdc unless otherwise specified.) PARAMETER NOTES and CONDITIONS NC12S0A0V/H15 Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage 14 Vdc Operating Temperature (Vertical) With appro...

Page 3 - ELECTRICAL CHARACTERISTICS CURVES; Converter efficiency vs. output current

NC12S15A_01102008 3 ELECTRICAL CHARACTERISTICS CURVES 0 10 20 30 40 50 60 70 80 90 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Output Current (A) Efficien cy (%) 10.2 12 13.8 0 10 20 30 40 50 60 70 80 90 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Output Current (A) Efficien cy (%) 10.2 12 13.8 Figure 1: Conver...

Page 6 - Typical transient response to step load change at

NC12S15A_01102008 6 ELECTRICAL CHARACTERISTICS CURVES Figure 19: Typical transient response to step load change at 10A/ μ S from 50% to 75% and 75% to 50% of Io_max at 12Vin, 0.9V out Figure 20: Typical transient response to step load change at 10A/ μ S from 50% to 75% and 75% to 50% of Io_max at 12...

Other Delta Models