Delta IPM- C Series - Manual

Delta IPM- C Series

Delta IPM- C Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Equipment Required
  • Page 3 – .0 Thermal Management of the Converter; o the converter at all times during all
  • Page 4 – Efficiency; Input Characteristics
  • Page 6 – Tests and Evaluation
  • Page 8 – ries; out
  • Page 9 – For I M04C series; Test
  • Page 10 – For IPM12C series; For IPM04C series; For example, to program the output voltage of a IPM
  • Page 11 – Dynamic Characteristics; Imax; ) Measure the Peak deviation and capture the waveform as required.
  • Page 12 – Test (Turn on the module by using the external switch); or suitable trigger point (referring to data sheet) on channel 2.
Loading the manual

1

Delta Electronics, Inc.

1.0 Purpose

This document guides the user in performing
electronic measurements on an IPM POL (point
of load) DC/DC converter using the Delta
Evaluation Board.


2.0 Relevant Documentation

The documentation and background information
listed below is relevant to this evaluation
procedure:

Applicative date sheets for IPM Series unit

under evaluation.

Power Module Evaluation Board Schematic.

Power Module Evaluation Board Layout.

General Test and Safety Procedures.



IPM Series



Evaluation Procedure
EP_IPMC_04292005

Evaluation Procedure

(DEP-003)

The IPM- C Series POL converters


The IPM Series, single output,

non-isolated

point of load DC/DC converters, are the latest
offering from a world leader in power systems
technology and manufacturing

Delta

Electronics, Inc. They operate from a
3V~5.5V (IPM04C) or an 8V~14V (IPM12C)
source and provide a programmable output
voltage of 0.8V to 3.3V(IPM04C) or 0.8V to
5V(IPM12C). With creative design technology
and optimization of component placement,
these converters possess outstanding
electrical and thermal performance, as well
as offering extremely high reliability under
highly stressful operating conditions. All
models are protected against abnormal
input/output voltage and current conditions.

This document guides the user through the
evaluation procedure to qualify a POL module.
The data shown in this Evaluation Procedure
is for the SIP and SMT Package Type POL
evaluation board. Please refer to the
appropriate technical data sheet for detailed
performance and technical information for the
specific POL units.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Equipment Required

3.0 Equipment Required ․ DC Power Supply 0 - 20 V @ 0 - 20A (Agilent 6574A 0 -60V/0 - 35A or equivalent). ․ Oscilloscope (Tektronix TDS 460A or equivalent) 4 Channel 400 MHz, equipped with a x1 scope probe, a x10 scope probe, and two BNC cables (length less than 20 inches/500mm) ․ Digital multimeter...

Page 3 - .0 Thermal Management of the Converter; o the converter at all times during all

4.1 Connect one lead from the “+” lead of the power supply to the “20A” terminal of the first 4.2 Connect one wire from the “-” lead of the power supply (Item 3.1) to the “Vin-“ pin of the 4.3 Connect the plus “+” and minus “-“ connection leads from a second multimeter to the “SVin+” 4.4 Connect the...

Page 4 - Efficiency; Input Characteristics

6.0 Tests Performed performed at room temperature (+25 C). 6.1 Input Voltage Range. ut. . 6.2 O Line Regulation. . t-Point Adjustment Range. 6.3 D Maximum Output Voltage Deviation (due to step change in load). 6.4 Efficiency e part number of the power module to determine that the correct module is b...

Other Delta Models