Delta IGT002 - Manual
Delta IGT002 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
¢J
I G T 0 0 2 Ty p e
DELTA ELECTRONICS, INC.
(TAOYUAN PLANT CPBG)
7 0
Via the system-provided input voltage 230-240V, the high voltage coil is stimulated
and gives the voltage output between 14KVo-p & 25KVo-p to start up the ignition system
of the gas furnance or the molecule ozonization of air cleaning M/C.
Features
Gas Igniter
Oil Igniter
Air Cleaner
Electronic Ozonizer
Applications
Mechanical Dimension:
U n i t : m m
17.0 0.5
33.0 Max.
29.0 Max.
4.0 0.5
25.0 0.5
18.5 0.5
1
2
b
a
1.2
1
2
3
4
PRI
SEC
H.V.
Schematic :
4
3
2
1
Electrical Characteristics:
252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com
PART NO.
PRIMARY
PRIMARY
INDUCTANCE (uH)
¢J
PRIMARY
SECONDARY
PRIMARY
SECONDARY
WEIGHT
PART NO.
INDUCTANCE (uH)
INDUCTANCE (mH)
DCR (m ) MAX.
DCR ( ) MAX.
I
GT-002
26.7 25%
94.0 25%
65
165
38g
25.0 Max.
23.8 0.5
o
A T 2 5 C , 6 5 % R H , I N D U C TA N C E T E S T E D @ 1 K H z / 1 V
o
o
Operation temperature
:
-40C to +105C
o
o
Storage temperature
:
-20C to +85C
Input voltage
:
240 Vdc
No-load voltage
:
14KV min.
Insulated with epoxy resin
Recommended Circuit:
+
-
240 Vdc
SUPPLY
DC
SW1
C1
2.2nf
SW2
1
2
T1
OUTPUT
50pf
4
3
C2
Ignition Coil
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.