Delta DVP-Slim - Manual

Delta DVP-Slim

Delta DVP-Slim – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

ht tp: //w ww. del ta .c om .tw /i nd us tr i al au toma ti on /

5011658300-MNE0

2007-01-23

Digital I/O Extension Unit
(Pin Headed)

Instruction Sheet

Warning

3

Please read this instruction sheet carefully before use.

3

DVP-Slim is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity,
electri shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or
specific tools are required to open the enclosure) in case danger and damage on the device may occur.

3

DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the
wiring again before switching on the power. DO NOT touch any terminal when the power is switched on.

X

Introduction

1.1 Model Explanation & Peripherals

Thank you for choosing Delta DVP-Slim series programmable logic controller. DVP-Slim series pin-headed digital I/O

extension unit offers 32 points. For DVP-SS/SA/SX/SC series MPU, the maximum digital I/O extension points (including

the MPU) can reach 128 points. For SV series MPU, the maximum digial I/O extension points (including the MPU) can

reach 256 points. In addition, maximum 8 additional special modules (AD/DA/PT/TC/XA/PU) can be extended to

DVP-Slim series extension unit.

Nameplate Explanation

VX.XXAX

24Vdc 1W
0.1A(24VDC)POINT

M A D E I N X X X X X

32SN11T NT 7020001

De l ta PLC mo del nam e

Pow er i n put s pec .

O utp ut poi n t modu l e s p ec .

Bar c od e & s er i al No.

Ver s i on

Model Name

Serial No.

I npu t poi nt e xt ens i o n u ni t

O utpu t poi nt e x tens i o n u ni t

M:
N:

DV P s er i es

Poi n ts ( 32 f or ou tpu t)

Mo dul e ty pe

T N:

N:

NPN t r ans i s tor

No o utpu t modu l e

DC p owe r i np ut

Pr odu c ti on N o.

Mo del name

Pr odu c ti on w eek

P r odu c ti on y ea r ( 2007 )
P r odu c ti on pl a nt

1.2 Product

Profile

Unit: mm

c

POWER, L.V (low voltage) indicator

h

Extension unit positioning hole

d

Model name

i

Nameplate

e

Extension unit fixing clip

j

Extension unit fixing clip

f

I/O terminals

k

DIN rail (35mm)

g

DIN rail clip

l

Connection port for extension unit

1.3 Model

Information

Input

Output

Model name

Power
supply Points

Type

Points

Type

Dimension

(mm)

Outline

DVP32SM11N

32

DC Type

Sink/Source

0 N/A

DVP32SN11TN

24V DC

0 N/A 32

(NPN)

Transistor

25.2 90 60

Y

Specifications

2.1 Electrical

Specifications

Model
Item

DVP32SM11N

DVP32SN11TN

Power supply voltage

24V DC (-15% ~ 20%) (with DC input polarity reverse protection)

Motion specification

Within 5ms of the momentary power loss, the device will keep on operating.

Power consumption

1W

1.5W

Insulation resistance

5 M

(all I/O point-to-ground: 500V DC)

Noise immunity

ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV,
Analog & Communication I/O: 1KV
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

Earth

The diameter of grounding wire shall not be less than that of L, N terminal of the
power. (When many PLCs are in use at the same time, please make sure every PLC
is properly grounded.)

Operation/storage
environment

Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2
Storage: -40ºC ~ 70ºC (temperature); 5 ~ 95% (humidity)

Shock/vibration
immunity

International standards: IEC1131-2, IEC 68-2-6 (TEST Fc)/IEC1131-2 & IEC 68-2-27
(TEST Ea)

Weight (g)

70g

70g

2.2 I/O Point Specifications

Input Point

Input type

DC (SINK or SOURCE)

Input current

24VDC, 5mA

Active level

Off

Æ

On more than 16V DC

On

Æ

Off less than 14.4V DC

Response time

Approx. 10ms, 0 ~ 15ms adjustable from D1020, D1021

Circuit isolation /
operation instruction

By photocoupler / LED On

Output Point

Output type

Transistor – T (NPN)

Current specification

0.1A/point

Voltage specification

5 ~ 24 VDC

Maximum load

55ºC/1A (COM), 25ºC/2.4A (COM)

Response time

Off

Æ

On less than 0.1ms

On

Æ

Off less than 0.3ms

Z

Installation & Wiring

3.1 Terminals of Digital I/O Extension Unit

DVP32SM11N

DVP32SN11TN

2 1

2 2

2 3

2 4

2 5

2 6

2 7

2 8

2 9

3 0

3 1

3 2

3 3

3 4

3 5

3 6

3 7

3 8

3 9

4 0

1

2

3

4

5

6

7

8

9

1 0

11

1 2

1 3

1 4

1 5

1 6

1 7

1 8

1 9

2 0

X 2 1
X 2 3
X 2 5
X 2 7
X 3 1
X 3 3
X 3 5
X 3 7
S/S
N C

X 1
X 3
X 5
X 7
X 11
X 1 3
X 1 5
X 1 7
S/S
N C

X 2 0
X 2 2
X 2 4
X 2 6
X 3 0
X 3 2
X 3 4
X 3 6

S /S

N C

X 0
X 2
X 4
X 6

X 1 0
X 1 2
X 1 4
X 1 6

S /S

N C

D V P 3 2 S M

2 1

2 2

2 3

2 4

2 5

2 6

2 7

2 8

2 9

3 0

3 1

3 2

3 3

3 4

3 5

3 6

3 7

3 8

3 9

4 0

1

2

3

4

5

6

7

8

9

1 0

11

1 2

1 3

1 4

1 5

1 6

1 7

1 8

1 9

2 0

Y 2 1
Y 2 3
Y 2 5
Y 2 7
Y 3 1
Y 3 3
Y 3 5
Y 3 7
G N D
+ 2 4 V

Y 1
Y 3
Y 5
Y 7
Y 11
Y 1 3
Y 1 5
Y 1 7
G N D
+ 2 4 V

Y 2 0
Y 2 2
Y 2 4
Y 2 6
Y 3 0
Y 3 2
Y 3 4
Y 3 6

G N D

+ 2 4 V

Y 0
Y 2
Y 4
Y 6

Y 1 0
Y 1 2
Y 1 4
Y 1 6

G N D

+ 2 4 V

D V P 3 2 S N

ƒ

DVP32SN currently only offers TN (NPN) transistor output.

ƒ

Please be aware of the following PIN wiring methods for DVP32SN to prevent burn-down of the extension unit.

1. PIN19, PIN20, PIN39 and PIN40 can only connected to +24V DC. The 4 points have already been designed as

short-circuit within the extension unit; therefore only 1 of the points needs to be wired.

2. PIN17, PIN18, PIN37 and PIN38 can only connected to GND. The 4 points have already been designed as

short-circuit within the extension unit; therefore only 1 of the points needs to be wired.

3.2 Connection

Step 1:

Screw open the side cover of the extension

unit and you will see the connection port.

Step 2:

Lift the fixing clip by the screwdriver.

Step 3:

Adjust the positioning hole of the MPU and

the extension unit and meet the connection port on

the MPU with the extension unit to tightly connect

the two.

Step 4:

Fasten the fixing clip on the extension unit

to complete the connection.

3.3 Installation & Wiring

Install the PLC in an enclosure with sufficient space around it to allow heat dissipation as shown in the figure below.

DVP

MPU

D

D

D

D

D > 50mm