Page 2 - Delta DOP Series HMI Connection Manual; Pin Definition of Serial Communication; RXD; NOT E; ) Transmission speed is relevant to distance and baud rate.
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-1 1.1 Pin Definition of Serial Communication DOP-A Series COM1 Mode PIN RS-232 1 N.C 2 RXD 3 TXD 4 N.C 5 GND 6 N.C 7 RTS 8 CTS 9 N.C COM2 Mode 1 Mode 2 Mode 3 PIN RS-232 RS-422 RS-485 1...
Page 4 - RXD RXD
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-3 DOP AS Series COM1/COM3 Mode 1 Mode 2 PIN RS-232 RS-232 x2 1 N.C N.C 2 RXD RXD 3 TXD TXD 4 N.C N.C COM 1 5 GND GND 6 N.C N.C 7 RTS TXD 8 CTS RXD COM 3 9 N.C N.C COM2 Mode 1 Mode 2 PIN...
Page 5 - Cable for Download; Download via COM Port; DOP series HMI; Download via USB Flash Drive; USB Connection
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-4 Revision January, 2008, Doc. Name: 2007PDD23000007 1.2 Cable for Download Download via COM Port RS-232 DOP series HMI 9 pin D-SUB male (RS-232) PC 9 pin D-SUB female (RS-232) Controller RXD (2) (3) TXD TXD (3) (2) RXD GND (5) (5) GND ...
Page 6 - Supported Controllers and Devices
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-5 1.3 Supported Controllers and Devices Please refer to the following table for supported controllers and devices provided by DOP series HMI. Brand Controller Name / Series Name Delta Con...
Page 8 - Back to Table; B. Definition of controller Read/Write address
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-7 Delta (Servo/AC Drive/PLC/Temperature) Controller Back to Table A. HMI factory setting Baud rate: ASCII: 9600, 7, None, 2. RTU: 9600, 8. None, 2. Controller station number: 1. Control a...
Page 9 - Contacts
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-8 Revision January, 2008, Doc. Name: 2007PDD23000007 Read/Write Range Register Type Format Word No. Bit No. Data Length Output Registers RW-n n: 0 ~ FFFFh N/A Word Input Registers R-n n: 0 ~ FFFFh N/A Word Output Registers Wn n: 40001 ~ 5...
Page 10 - Pay close attention to the following important notes:; Therefore, setting INVERTER901 to HMI will discard the first 0); The communication address of parameter 9-01 is 0901H.; The communication address of parameter 8-17 is 0811H.
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-9 2) PLC Word Device X and Y are in octal format. Other PLC Word Device M, S, T, C, D and HC are in decimal format. 3) Servo Digital Input and Servo Digital Output are only for Servo. Pay...
Page 11 - Delta Servo; Top Vi e w
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-10 Revision January, 2008, Doc. Name: 2007PDD23000007 C. Connections (Connector Pinouts) Delta Servo RS-232 DOP Series 9 pin D-SUB male (RS-232) Controller CN3 cable connector (RS-232) Controller CN3 cable connector (RS-232) R X D (2 ) (2...
Page 12 - Delta AC drive; Top View; Temperature Controller
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-11 Delta AC drive RS-485 DOP Series 9 pin D-SUB male (RS-485) Controller RJ-11 cable connector (RS-485) Controller RJ-11 cable connector (RS-485) R XD + ( 2 ) (4 ) S G + T X D+ (3 ) R XD ...
Page 15 - AllenBradley MicroLogix PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-14 Revision January, 2008, Doc. Name: 2007PDD23000007 AllenBradley MicroLogix PLC Back to Table A. HMI factory setting Baud rate: 19200, 8, None, 1. PLC station number: 1. Control area/status area: B3:0/B3:10. B. Definition of controller ...
Page 18 - AllenBradley SLC5 PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-17 AllenBradley SLC5 PLC Back to Table A. HMI factory setting Baud rate: 19200, 8, None, 1. PLC station number: 1. Control area/status area: B3:0/B3:10. NOT E 1) Error Check uses CRC (Cyc...
Page 27 - S h e l l; Explanation of Control Word & Status Word; Control Word
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-26 Revision January, 2008, Doc. Name: 2007PDD23000007 Contacts Read/Write Range Word No. Bit No. Low Byte High Byte Contact Type Format Element No. Bits Index No. Parameter Pn:I.b n: 0 ~ 999 b: 0 ~ 31 I: 0 ~ 31 ¾ Bit No : Low byte stores ...
Page 34 - ) It needs to use the dedicated cable for FESTO controllers
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-33 C. Connections NOT E 1) Communication port of PLC: COM port 2) It needs to use the dedicated cable for FESTO controllers Æ Cable for transferring TTL to RS-232 and it is 6 pin RJ-12 co...
Page 35 - GE Fanuc 90 Series SNP PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-34 Revision January, 2008, Doc. Name: 2007PDD23000007 GE Fanuc 90 Series SNP PLC Back to Table A. HMI factory settings Baud rate: 19200, 8, ODD, 1. Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) t...
Page 36 - Top Vi ew
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-35 Contacts Read/Write range Contact Type Format Word No. Bit No. Discrete Inputs %In N/A n: 1 ~ 12288 Discrete Outputs %Qn N/A n: 1 ~ 12288 Discrete Temporaries %Tn N/A n: 1 ~ 256 Discre...
Page 41 - Jetter Nano Series PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-40 Revision January, 2008, Doc. Name: 2007PDD23000007 Jetter Nano Series PLC Back to Table A. HMI factory settings Baud rate: 9600, 8, EVEN, 1 (RS-232). Controller station number: 0. (no PLC station number in protocol, therefore, only 1(H...
Page 42 - If exceeds this range, HMI will stop read/write operation and show “
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-41 if the read/write address format is set to Rn, only Bit 0 ~ 23 are valid for Rn registers. (Notice: As the Jetter controller is a 24-bit format controller, the valid setting range is 2...
Page 46 - KV Series
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-45 NOT E When using the protocol format of KV series and connecting to KZ-80T PLC, some errors occur. Please refer to the following description: 1) Readable Timer address is not continuou...
Page 52 - ddress Corresponding Relationship:; K sequence
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-51 The corresponding registers of CCM2 and K-Sequence A ddress Corresponding Relationship: CCM2 K sequence SN32DRA V R R X X I Y Y Q C M M S S S T T T CT C C SP SP SP
Page 61 - SDA
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-60 Revision January, 2008, Doc. Name: 2007PDD23000007 C. Connections (Connector Pinouts) RS-232 via CPU Port DOP 9 pin D-SUB male (RS-232) Controller 9 pin D-SUB male (RS-232) Controller 9 pin D-SUB male (RS-232) R XD (2 ) (7 ) TXD TXD ( ...
Page 73 - Mitsubishi FX/FX2N PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-72 Revision January, 2008, Doc. Name: 2007PDD23000007 Mitsubishi FX/FX2N PLC Back to Table A. HMI factory settings Baud rate: 9600, 7, EVEN, 1. Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 ...
Page 77 - Mitsubishi A Series AJ71UC24 Communication Module
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-76 Revision January, 2008, Doc. Name: 2007PDD23000007 Mitsubishi A Series AJ71UC24 Communication Module Back to Table A. HMI factory settings Baud rate: 9600, 8, ODD, 1. Controller Station number: 0. Control area/status area: D0 / D10. NO...
Page 79 - where PX and X differ.
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-78 Revision January, 2008, Doc. Name: 2007PDD23000007 Mitsubishi A2A/A2AS/A2USH A1SH/A3N/A2ASH (CPU-S1) CPU Port Back to Table A. HMI factory settings Baud rate: 9600, 8, ODD, 1. Controller Station number: 0. (no PLC station number in pro...
Page 82 - Mitsubishi Q Series CPU Port
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-81 Mitsubishi Q Series CPU Port Back to Table A. HMI factory settings Baud rate: 19200, 8, ODD, 1. Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI)...
Page 105 - ON
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-104 Revision January, 2008, Doc. Name: 2007PDD23000007 Inter Memory of Delta HMI Modbus Reference Address Supporting Modbus Function Address of Function $M200.1 01026 01H, 05H, 0FH 0401H . . . $M200.15 01040 01H, 05H, 0FH 040FH $M201.0 01...
Page 108 - DOP
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-107 Modicon TSX Micro (Modbus RTU) Back to Table A. HMI factory settings Baud rate: 9600, 8, ODD, 1. Controller station number: 2. Control area/status area: %MW0 / %MW10. NOT E 1) HMI mus...
Page 109 - Modicon TWIDO; Its function is the same as
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-108 Revision January, 2008, Doc. Name: 2007PDD23000007 Modicon TWIDO Back to Table Its function is the same as Modbus (Master) --- 984 RTU .
Page 111 - Setting
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-110 Revision January, 2008, Doc. Name: 2007PDD23000007 NOT E 1) Communication Setting The read and write range of register Marker (Device MW) of PS4 Series must be set via PC software or PLC program before connecting to HMI; otherwise, th...
Page 113 - Contact type
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-112 Revision January, 2008, Doc. Name: 2007PDD23000007 For example, if setting the starting address as RW900 and the data size is Double Word, the read/write value will be a Double Word which contains RW900(low word) and RW901(high word)....
Page 117 - Omron CJ1/CS1 Series PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-116 Revision January, 2008, Doc. Name: 2007PDD23000007 Omron CJ1/CS1 Series PLC Back to Table A. HMI factory settings Baud rate: 9600, 7, EVEN, 2. (RS-232) Controller station number: 0. Control area/status area: D0 / D10. ¾ This driver ca...
Page 120 - Omron TPM1A PLC; Omron C Series PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-119 Omron TPM1A PLC Back to Table Its function is the same as Omron C Series PLC .
Page 126 - ) PLC baud rate should be changed to; DB
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-125 Siemens S7 300 PLC (without PC Adaptor) Back to Table A. HMI factory settings Baud rate: 19200, 8, EVEN, 1. (RS-485). Controller station number: 2. Control area/status area: DBW0 / DB...
Page 134 - VIPA PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series Revision January, 2008, Doc. Name: 2007PDD23000007 1-133 VIPA PLC Back to Table Its function is the same as Siemens S7 300 PLC (with PC Adaptor) .
Page 135 - YOKOGAWA ACE PLC
Delta DOP Series HMI Connection Manual | DOP-A/AE/AS Series 1-134 Revision January, 2008, Doc. Name: 2007PDD23000007 YOKOGAWA ACE PLC Back to Table A. HMI factory settings Baud rate: 9600, 8, EVEN, 1. (ASCII code) Controller station number: 1. CPU NO. : 1. Control area/status area: D1 / D10. NOT E 1...