42 x 45 x 19 MM SERIES
BFB
DIMENSIONS DRAWING
Bearing Type
Ball Bearings
Material
Impeller & Frame : Plastic (UL 94V-0)
Lead Wires :
UL 1061 AWG #26 O Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
Weight : 22g (0.78 oz)
R
*
*
*
*
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
Operating
Voltage
Range
MODEL
Rated
Voltage
Maximum
Air Flow
Speed
Maximum
Air Pressure
Noise
FUNCTION VDC VDC Amp Watt R.P.M.
3
m /min CFM mmH
2
O IN H
2
O dB-A
P & Q CURVE
(AT RATED VOLTAGE)
100
(0.197)
5.0
(1
3
.5
0
4
0
.3
9
4
)
3
4
3
.0
1
0
.0
(0
.3
9
4
)
1
0
.0
(0.571 0.012)
14.5 0.3
22.0 0.5
(2- 0.106 0.012)
2- 2.7 0.3
(1
.2
6
0
0
.0
2
0
)
(1
.0
4
3
0
.0
2
0
)
3
2
.0
0
.5
2
6
.5
0
.5
(0.583 0.020)
(0.728 0.020)
18.5 0.5
14.8 0.5
(0.709 0.012)
(1.654)
(1
.7
5
2
)
(0
.7
0
9
0
.0
1
2
)
(1
.4
1
7
0
.0
2
0
)
4
4
.5
3
6
.0
0
.5
1
8
.0
0
.3
42.0
18.0 0.3
mm
(INCH)
UNIT:
( 0.866 0.020)
BFB0405LE
-R00 / -F00
5
4.0 to 5.5
0.06
0.30
3500
0.046
1.62
3.23
0.127
26.0
BFB0412LE
-R00 / -F00
12
10.0 to 13.8
0.04
0.48
BFB0405ME
-R00 / -F00
5
4.0 to 5.5
0.13
0.65
4500
0.059
2.08
5.92
0.233
30.0
BFB0412ME
-R00 / -F00
12
10.0 to 13.8
0.05
0.60
BFB0405HE
-R00 / -F00
5
4.0 to 5.5
0.22
1.10
5500
0.072
2.54
9.72
0.383
35.5
BFB0412HE
-R00 / -F00
12
10.0 to 13.8
0.07
0.84
BFB0412HHE
-R00 / -F00
12
10.0 to 13.8
0.11
1.32
6500
0.084
2.97
14.15
0.557
39.5
3
(M /MIN)
(I
N
H
O
)
2
(m
m
H
O
)
2
0.60
0.50
0.40
0.30
0.20
0.10
0
A
ir
P
re
s
s
u
re
3.2
2.4
1.6
0.8
0
Air Flow
(CFM)
BFB0405/12XE
0
.02
.04
.08
.06
.10
15.0
12.5
10.0
5.0
2.5
0
7.5
L
M
H
HH
PART NO.
http://www.deltaww.com
Input
Power
Input
Current
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.