Delta BE Series - Manual

Delta BE Series

Delta BE Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

D

V

E

4-7

A: with ground choke

CURRENT

FREQUENCY-MHz

RATING

.15

.50

1.0

5.0

10

30

3A (G) (A)

20

30

35

35

35

35

COMMON MODE (L-G) IN 50 OHM SYSTEM

DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM

6A (G) (A)

10

20

25

35

40

35

10A (G) (A)

5

10

20

30

35

35

3A (G) (A)

4

10

20

35

35

40

6A (G) (A)

4

10

10

35

35

40

10A (G) (A)

5

10

20

30

35

35

BENG3G

BEEG3G

1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC

L

O

Cy

A
D

Cy

L'

N'

G'

Cx

L

SW

L

I

L

N
E

G

N

R

R: OPTION

I

N

G

E

N

L

L

SW

R

Cx

N'

L'

G'

Cy

Cy

L

O

D

A

L

Lg

3GA ONLY

UNIT:

INCH

mm

1.563 0.004

1

.1

1

2

0

.0

0

4

SUGGESTED MOUNTING CUTOUT

(MOUNTING FROM FRONT)

1.22 0.004

1.713REF.
43.5REF.

2.146REF.
54.5REF.

2.264REF.
57.5REF.

4

1

.0

1

.6

1

4

R2.5(8X)

R0.098(8X)

R0.14

R3.5

1

.5

0

R

E

F

.

3

8

.3

R

E

F

.

39.7 0.1

2

8

.2

5

0

.1

31.0 0.1

BENG3G

Suggested thickness of mounting
panel is from 0.04(1.0) to 0.63(1.6) inch(mm)
of mounting cutout

2.4

0.8

0.3

1M

0.1

2200

0.12

PART NO.

Cx (uF) L (mH) Cy (pF) R (

) Lg (mH)

03BEEG3G/NG3G/-R
03BEEG3GA/NG3GA/-R
06BEEG3G/NG3G/-R
06BEEG3GA/NG3GA/-R
10BEEG3G/NG3G/-R
10BEEG3GA/NG3GA/-R

R0.098(8X)

1

.6

1

4

SUGGESTED MOUNTING CUTOUT

(MOUNTING FROM FRONT)

R3.5

1

.1

2

2

0

.0

0

4

M3

1.535 0.004

1

.5

0

R

E

F

.

1.713REF.

3

8

.3

R

E

F

.

R2.5(8X)

R0.14

2

8

.5

0

.1

39.0 0.1

43.5REF.

2.146REF.

54.5REF.

2.264REF.

57.5REF.

1.417

36.0

4

1

.0

1

.4

1

7

0

.0

0

4

3

6

.0

0

.1

BEEG3G

P

O

W

E

R

E

N

TR

Y

M

O

D

U

LE

F

IL

TE

R

S

SERIES

SWITCH CONNECTOR FILTERS

SPECIFICATIONS

1. Designed as a general purpose filter with a switch
effective EMI suppression for both common and
differential mode noise.
2. With optional resistor and 3300pF/1000pF
3. Bleader resistor is added with suffix "-R".
4. Switch electrical lifetime : 10,000 cycles.
Maximum inrush current : 50A.

INTRODUCTIONS

COMPONENTS

MINIMUM INSERTION LOSS IN dB

MECHANICAL CONSTRUCTION

ELECTRICAL SCHEMATIC

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.