Delta AFB Series - Manual

Delta AFB Series

Delta AFB Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

Air Pressure

Air Flow

(mm H

2

O)

(IN H

2

O)

(M

3

/MIN)

(CFM)

UNIT :

(INCH)

mm

UNIT :

(INCH)

mm

INLET SIDE

OUTLET SIDE

HH

H

M

L

0

0.6

1.2

1.8

2.4

0

0.06

0.12

0.18

0.24

0.30

0.36

4.5

0

1.5

3.0

6.0

7.5

9.0

.075

.045 .060

.030

.015

0

AFB02505/12XA-A

LABEL

20.0±0.3

25.0±0.5

(0.984±0.020)

(0.787±0.012)

(0.787±0.012)

(0.984±0.020)

25.0±0.5

20.0±0.3

10.0±0.5

(0.394±0.020)

10.0

150.0±10.0

(0.394)

(5.906±0.394)

4-Ø2.8±0.3

(4-Ø0.110±0.012)

20.0 (0.787)

(0.787)

20.0

Ø24.0

(Ø0.945)

20.0

(0.787)

(0.787)

20.0

(Ø0.945)

Ø24.0

4-Ø2.8

(4-Ø0.110)

(4-Ø0.110)

4-Ø2.8

http://www.deltaww.com

AFB

DIMENSIONS DRAWING

P & Q CURVE

(AT RATED VOLTAGE)

MOUNTING PANEL CUTOUT

25 x 25 x 10 MM SERIES

*

Bearing Type

Ball Bearings

*

Material

Impeller & Frame : Plastic(UL 94V-0)

*

Lead Wires :

UL 1061 AWG #26 OR Equivalent

Red Wire Positive(+)

Black Wire Negative(-)

*

Weight : 10.5g (0.37 OZ)

*

Rib Type Only & One Side Flange

MODEL

Rated

Voltage

Operating

Voltage

Range

Input

Current

Input

Power

Speed

Maximum

Air Flow

Maximum

Air Pressure

Noise

PART NO.

REV. FUNCTION

VDC

VDC

Amp

Watt

R.P.M. m

3

/min

CFM

mmH

2

O

IN H

2

O

dB-A

AFB02505LA

-A -R00 / -F00

5

4.0 to 5.5

0.04

0.20

5000

0.024

0.85

1.15

0.045

18.0

AFB02505MA

-A -R00 / -F00

5

4.0 to 5.5

0.06

0.30

7000

0.034

1.20

2.18

0.085

20.0

AFB02512MA

-A -R00 / -F00

12

9.5 to 13.2

0.04

0.48

AFB02505HA

-A -R00 / -F00

5

4.0 to 5.5

0.12

0.60

10000

0.052

1.84

4.48

0.176

23.5

AFB02512HA

-A -R00 / -F00

12

7.0 to 13.2

0.06

0.72

AFB02505HHA

-A -R00 / -F00

5

4.0 to 5.5

0.16

0.80

13000

0.068

2.40

7.65

0.300

28.0

AFB02512HHA

-A -R00 / -F00

12

7.0 to 13.2

0.08

0.96

* Function type is optional.

* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.

* Noise is measured in anechoic chamber in free air, one meter from intake side.

* All readings are typical values at rated voltage.

* Specifications are subject to change without notice.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.