Page 3 - IMPORTANT SAFETY INSTRUCTIONS; Save these instructions; WARNING: Risk of explosion or fire
3- ENG D26316 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury andproperty damage. Read and understand all warnings and operation instructions beforeusing this equipment. HAZARD WARNING: Risk of explosion or fire H...
Page 4 - HAZARD
4- ENG D26316 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen WARNING: Risk from Flying Objects HOW TO PREVENT IT WHAT CAN...
Page 8 - GLOSSARY; CFM; DUTY CYCLE
8- ENG D26316 GLOSSARY Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or mo...
Page 9 - INSTALLATION; Location of the Air Compressor; HOW TO SET UP YOUR UNIT; GROUNDING INSTRUCTIONS; The outlet being used must be; DO NOT
INSTALLATION Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The aircompressor should be located at least 12" away from the wall or otherobstructions that will interfere with the flow of air. The air compressor pumpand shroud are designed to all...
Page 10 - Voltage and Circuit Protection; Voltage supply is 108V-132V AC at the outlet.; Extension Cords; in good condition
10- ENG D26316 Voltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuitrequirements. Certain air compressors can be operated on a 15 amp circuit if the followingconditions are met. 1. Voltage supply is 108V-132V AC at the outlet. 2. Circuit is not used to s...
Page 11 - OPERATION; Know Your Air Compressor; Outlet Pressure Gauge:
11- ENG D26316 OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATINGYOUR UNIT. Compare the illustrations with your unit to familiarize yourself withthe location of various controls and adjustments. Save this manual for futurereference. Description of Operation...
Page 12 - Before Starting; before; How to Use Your Unit
12- ENG D26316 Before Starting Break-in Procedure Serious damage (for units with a tank) may result if thefollowing break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been...
Page 13 - MAINTENANCE; Customer Responsibilities; Before each use; To Check Safety Valve; Remove the air tool or accessory.; NOTE
13- ENG D26316 MAINTENANCE Customer Responsibilities Daily or aftereach use Before each use Check Safety Valve ● Drain Tank ● To Check Safety Valve If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. Before starting compressor, pull th...
Page 14 - To Replace or Clean Check Valve; Replace the outlet tube and tighten the nut.; SERVICE AND ADJUSTMENTS; Unplug or disconnect electrical supply to the air compressor.
14- ENG D26316 To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in theMaintenance section. 2. Unplug unit. 3. Loosen the nut on the outlet tube andmove the outlet tube to the side. 4. Unscrew the check valve (turn counterclockwise) using a socket...
Page 15 - To Replace Regulator; risk of air tank rupture.; STORAGE
15- ENG D26316 To Replace Regulator 1. Release all air pressure from air tank. See "To Drain Tank" in theMaintenance section. 2. Unplug outfit. 3. Using an adjustable wrench remove the gauges and hose from the regulator. 4. Remove the regulator. 5. Apply pipe sealant tape to the nipple on th...
Page 16 - TROUBLESHOOTING
16- ENG D26316 Performing repairs may expose voltage sources, movingparts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attemptingany repairs, unplug the air compressor and bleed off all air tank airpressure. PROBLEM CAUSE CORRECTION Pressure ...
Page 17 - Adjust the regulated
17- ENG D26316 Regulator willnot shut off airoutlet. Damaged regulator. Replace. PROBLEM CAUSE CORRECTION It is normal for "some"pressure drop to occur. If there is an excessiveamount of pressure dropwhen the accessory is used,adjust the regulator followingthe instructions in the"Descrip...
Page 18 - Check the extension cord.
18- ENG D26316 PROBLEM CAUSE CORRECTION Motor will notrun. Check fuse box for blownfuse and replace asnecessary. Reset circuitbreaker. Do not use a fuse orcircuit breaker with higherrating than that specified foryour particular branch circuit. Check for proper fuse. Youshould use a time delay fuse. ...
Page 19 - NOTES
Page 20 - AIR COMPRESSOR DIAGRAM
20- ENG D26316 AIR COMPRESSOR DIAGRAM 17 18 16 13 14 12 11 10 15 8 7 4 5 6 9 1 2 3 19
Page 21 - PARTS LIST; Key No
21- ENG D26316 PARTS LIST Key No Part Number Description 1 H-2099 Adapter 2 Z-GA-369 Pressure Gauge 3 CAC-4296-1 Regulator 4 SS-1286 Nipple 5 SSP-6021 Bushing Reducer 6 D20114 Safety Valve 7 Z-DAC-4105-2 Pressure Switch 8 SSP-480 Nipple 9 SSW-7480 Strain Relief Bushing 10 SSW-7367 Strain Relief Bush...
Page 22 - AIR COMPRESSOR PUMP DIAGRAM
22- ENG D26316 AIR COMPRESSOR PUMP DIAGRAM 1 15 20 14 16 13 12 7 4 10 11 9 8 6 5 3 21 2 18
Page 24 - LIMITED WARRANTY
24- ENG D26316 LIMITED WARRANTY DELTA MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, airtools, service parts, pressure washers, and generators,...