Loading the manual

Through Hole Power Inductors

T H A H 1 4 8 5 & 1 4 1 1 Ty p e

Mechanical Dimension:

RoHS compliant.
High current ( lsat up to 40A ) though hole type.
Magnetically shielded, suitable for hight density mounting.
High energy storage and low DCR.
Ideal for power source circuits, DC-DC converter,
DC-AC inverters inductor application.
In addition to the standard versions shown here,
customized inductors are available to meet your exact requirements.

Features

Electrical Characteristics:

DELTA ELECTRONICS, INC.

(TAOYUAN PLANT CPBG)

At 25

: 100KHz, 1.0V

o

C

252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com

1 4 8

DCR

(m ) MAX

I sat

(Adc)

Li

(uH) MIN

2

Lo

(uH)

1

PART NO.

Dimension "C"

(mm / inch) MAX

THAH1485-0R4

0.40

0.320

0.9

40

8.5 / 0.335

THAH1485-0R5

0.50

0.375

0.9

40

8.5 / 0.335

THAH1411-0R7

0.70

0.547

1.1

40

10.5 / 0.413

THAH1411-0R8

0.80

0.576

1.1

40

10.5 / 0.413

U N I T : m m / i n c h
A = 1 3 . 5 0 / 0 . 5 3 1 M a x .
B = 1 3 . 5 0 / 0 . 5 3 1 M a x .
D = 1 6 . 0 0 0 . 5 / 0 . 6 3 0 0 . 0 2 0
E = 3 . 5 0 0 . 5 / 0 . 1 3 8 0 . 0 2 0

F = 1 . 7 0 / 0 . 0 6 7

D

16.0+/-1.0

2.0(REF.)

F

C

A

B

E

1. Lo is the initial inductance and the tolerance is 20%.
2. Isat is the DC current which cause the inductance drop not lower than Li.

O

O

3. Operating temperature : -40

C

to 125

C

( including self-temperature rise ).

RECOMMENDED PAD PATTERNS