Delta 115V Series - Manual

Delta 115V Series

Delta 115V Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
175 Page 175
176 Page 176
177 Page 177
178 Page 178
179 Page 179
180 Page 180
181 Page 181
182 Page 182
183 Page 183
184 Page 184
185 Page 185
186 Page 186
187 Page 187
Page: / 187

Table of Contents:

  • Page 4 – Preface; PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.
  • Page 6 – Table of Contents
  • Page 10 – Chapter 1 Introduction; Receiving and Inspection; Inspect the unit to assure it was not damaged during shipment.; VFD
  • Page 11 – P r od u ct i on n u mb e r; any problems, please contact your distributor.
  • Page 12 – Installation Steps; Remove front cover screw and open.
  • Page 13 – Install Conduit Bracket cover and tighten screws.
  • Page 14 – of the electrolytic capacitors.
  • Page 15 – This page intentionally left blank.
  • Page 16 – Chapter 2 Installation and Wiring; Ambient Conditions
  • Page 17 – Mounting Clearances
  • Page 31 – to observe the following precautions when wiring.
  • Page 32 – Basic Wiring Diagrams
  • Page 33 – OFF; MC
  • Page 34 – For VFDXXXSXXE; IM
  • Page 35 – I M
  • Page 36 – Items Explanations
  • Page 38 – terminals of AC motor drives.; Grounding terminals (; directly to a common ground terminal, as shown in the figure below.; Ensure there are; good
  • Page 39 – RA; MCM; Terminal symbols and functions
  • Page 41 – I n t e r na l C i r c u i t; AV I; f er r i t e co r e; wind each wires 3 times or more around the core
  • Page 42 – diode across the coil and check the polarity.; General; avoid interference. If necessary let them cross only at 90o angle.; N OT E; in contact with high voltage.
  • Page 43 – Po we r t er mi na l
  • Page 45 – Po we r t er mi nal
  • Page 49 – This page intentionally left blank
  • Page 50 – Chapter 3 Start Up; Carefully check the following items before proceeding.
  • Page 51 – Operation Method; Check if the motor direction of rotation is correct.
  • Page 52 – hazardous voltage levels, even if the power has been turned off.
  • Page 54 – Chapter 4 Digital Keypad Operation; Description of the Digital Keypad; Explanation of LED Indicators; Display Message; Displays the AC drive Master Frequency.
  • Page 56 – How to Operate the Digital Keypad; To s h if t d a ta; S et t in g d ire c t io n; S et t in g Mo d e
  • Page 58 – Chapter 5 Parameters
  • Page 59 – Summary of Parameter Settings
  • Page 61 – Settings
  • Page 69 – Parameter Settings for Applications; Conveying machinery
  • Page 70 – General application
  • Page 71 – Pump and fan
  • Page 74 – Description of Parameter Settings; Group 0: User Parameters
  • Page 77 – E N D
  • Page 79 – Group 1: Basic Parameters
  • Page 80 – Vol t ag e
  • Page 83 – Acceleration S-Curve; Jog Decelerating Time
  • Page 84 – Group 2: Operation Method Parameters; Source of Master Frequency Command
  • Page 86 – RU N; Freq ue nc y; r amp t o st o p a n d fre e ru n to s t o p
  • Page 88 – Group 3: Output Function Parameters; An al og Freque ncy Met er; An al og Cu rre nt Me te r
  • Page 90 – Setting
  • Page 92 – Group 4: Input Function Parameters
  • Page 93 – This example shows a potentiometer range of 0 to 5 Volts.
  • Page 94 – gain is used to allow the Maximum Output Frequency to be reached.; Pot ent i ome t er Sca le
  • Page 95 – Pot en ti om eter Scale
  • Page 96 – d0 Parameter Disable:; d1 Two wire operation:; conjunction with M1 to operate two and three wire control.; d3 Three Wire Control:; S T OP
  • Page 97 – must be used for three wire control as shown above.; cleared and the AC drive is reset.
  • Page 98 – d10 Jog Operation Control:; d11 Acceleration/Deceleration Speed Inhibit:
  • Page 100 – Frequency each time an input is received.
  • Page 101 – s internal counter. When an input is; processing step or unit of material. See the diagram below.
  • Page 102 – d22 PID function disable:
  • Page 106 – steps in the Reverse direction.; F WD
  • Page 107 – PLC Forward/Reverse Motion; decimal notation and then be entered.; Wei ght s
  • Page 109 – Group 6: Protection Parameters
  • Page 110 – Over -vol tage St al l Prevention
  • Page 113 – Reserved
  • Page 114 – Group 7: Motor Parameters
  • Page 115 – Group 8: Special Parameters; Out p ut F re qu en cy; DC Bra ki n g Vol tage %
  • Page 119 – Group 9: Communication Parameters; Co mpu ter
  • Page 121 – ASCII; parity
  • Page 127 – Content Address
  • Page 131 – mode on a PC in C language.
  • Page 132 – Group A: PID Control
  • Page 134 – S l ee p F u n c t i o n; Sl e ep P e ri o d
  • Page 135 – Out put Valu e; I np ut; O u t pu t; A c tu a l va l ue
  • Page 137 – Chapter 6 Fault Code Information
  • Page 140 – Chapter 7 Troubleshooting; o c A
  • Page 141 – Chapter 7 Troubleshooting; G F F; Grou nd f a ul t
  • Page 144 – Keypad Display is Abnormal; el i minat e no is e; Ch ec k wi ri ng a t R, S an d T t er min al s
  • Page 145 – Motor cannot Run
  • Page 146 – Motor Speed cannot be Changed
  • Page 147 – Motor Stalls during Acceleration
  • Page 148 – solving it from the outside as follows will be the best.; Environmental Condition
  • Page 149 – Affecting Other Machines; se ria l react or
  • Page 150 – Chapter 8 Maintenance and Inspections
  • Page 156 – Appendix A Specifications; Voltage Class
  • Page 158 – Appendix B Accessories; B.1 All Brake Resistors & Brake Units Used in AC Motor Drives; Voltage
  • Page 159 – installation and operation.; B.1.1 Dimensions and Weights for Brake resistors
  • Page 160 – Installation; General precaution
  • Page 161 – Use the cable with shielding (double shielding is the best).; sa dd le; Saddle on both ends
  • Page 162 – The length of motor cable
  • Page 163 – sum of the wiring length from AC motor drive to each motor.
  • Page 167 – B.3.1 AC Input Reactor Recommended Value; kW HP
  • Page 168 – B.3.2 AC Output Reactor Recommended Value
  • Page 170 – Correct wiring; M n; Application 2
  • Page 171 – Application 3
  • Page 172 – B.4 DC Choke Recommended Values
  • Page 173 – Motor; Recommended W ire Size; es
  • Page 174 – Models
  • Page 177 – Fuse Specification Chart
  • Page 178 – Appendix C How to Select the Right AC Motor Drive; Related Specification
  • Page 179 – Appendix D CE; C.1 Capacity Formulas; When one AC motor drive operates one motor; The starting capacity is; Acceleration time; Acceleration time
  • Page 180 – Symbol explanation; GD
  • Page 181 – C.2 General Precautions; Selection Note; current and improve the input power efficiency.; Parameter Settings Note; upper limit frequency function is strongly recommended.
  • Page 182 – both the motor and the AC Motor Drive.; C.3 How to Choose a Suitable Motor; Standard motor; following precautions:; to
  • Page 183 – inverter duty motor.
  • Page 184 – Gear reduction motor:; Power Transmission Mechanism; above, lifetime reducing noises and vibrations may occur.; Motor torque; mains power are different.
  • Page 185 – AC motor drive; 0 s e c o n d s
  • Page 186 – EC Declaration of Conformity; For the following equipment:
Loading the manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - Preface; PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Preface Thank you for choosing DELTA’s high-performance VFD-S Series. The VFD-S Series is manufactured with high-quality components and materials and incorporate the latest microprocessor technology available. This manual is to be used for the installation, parameter setting, troubleshooting, and da...

Page 6 - Table of Contents

Table of Contents Preface .............................................................................................................. i Table of Contents ........................................................................................... iii Chapter 1 Introduction ...........................

Page 10 - Chapter 1 Introduction; Receiving and Inspection; Inspect the unit to assure it was not damaged during shipment.; VFD

Revision August 2006, SE08, SW V2.61 1-1 Chapter 1 Introduction 1.1 Receiving and Inspection This VFD-S AC motor drive has gone through rigorous quality control tests at the factory before shipment. After receiving the AC motor drive, please check for the following: Check to make sure that the packa...

Other Delta Models