Delta 0.59V~5.1Vout - Manual

Delta 0.59V~5.1Vout

Delta 0.59V~5.1Vout – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – TECHNICAL SPECIFICATIONS; PARAMETER
  • Page 3 – ELECTRICAL CHARACTERISTICS CURVES
  • Page 6 – DESIGN CONSIDERATIONS; the signal is driven low; Safety Considerations; FEATURES DESCRIPTIONS; Enable; is the falling threshold; is the rising threshold that you want.
  • Page 7 – Output Voltage Programming; Figure 19: Enable Input drive circuit for NE series; Over-Current and Short-Circuit Protection; Vout; Output Voltage; open; Table 1: Typical trim resistor values
  • Page 8 – Figure 22: Circuit configuration for output voltage margining; Paralleling; the Trim pin to the Ground for margining; Voltage Margining Adjustment
  • Page 9 – THERMAL CONSIDERATION; Thermal Testing Setup; Wind tunnel test setup figure dimensions are in
  • Page 11 – MECHANICAL DRAWING
  • Page 12 – WARRANTY
Loading the manual

Delphi NE Series Non-Isolated Point of Load

DC/DC Modules:

4.5V~13.8Vin, 0.59V~5.1Vout, 20A


The Delphi NE 20A Series, 4.5 to 13.8V wide input, wide trim single
output, non-isolated point of load DC/DC converters are the latest
offering from a world leader in power systems technology and
manufacturing

Delta Electronics, Inc. The ND/NE product family is

the second generation, non-isolated point-of-load DC/DC power
modules for the datacom applications which cut the module size by
almost 50% in most of the cases compared to the first generation NC
series POL modules. The product family here provides 20A of output
current in a vertically or horizontally mounted through-hole package
and the output can be resistor trimmed from 0.59Vdc to 5.1Vdc. It
provides a very cost effective, high efficiency, and high density point
of load solution. With creative design technology and optimization of
component placement, these converters possess outstanding
electrical and thermal performance, as well as extremely high
reliability under highly stressful operating conditions.

OPTIONS

Vertical or horizontal versions

APPLICATIONS

DataCom

Distributed power architectures

Servers and workstations

LAN/WAN applications

Data processing applications

FEATURES

High Efficiency:

94.0% @ 12Vin, 5V/20A out

Size:

Vertical: 30.5x15.5x12.0mm

(1.20”x0.61”x0.47”)

Horizontal: 30.5x15.5x12.9mm

(1.20”x0.61”x0.51”)

Wide input range: 4.5V~13.8V

Output voltage programmable from

0.59Vdc to 5.1Vdc via external resistors

Voltage and resistor-based trim

No minimum load required

Fixed frequency operation

Input UVLO, output OCP

Remote ON/OFF (Positive)

ISO 9001, TL 9000, ISO 14001, QS9000,

OHSAS18001 certified manufacturing facility

UL/cUL 60950 (US & Canada), TUV

(EN60950) --pending

PRELIMINARY DATASHEET
DS_NE12S20A_072722007

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL SPECIFICATIONS; PARAMETER

Preliminary DS_NE12S20A_07272007 2 TECHNICAL SPECIFICATIONS (Ambient Temperature=25°C, minimum airflow=200LFM, nominal V in =12Vdc unless otherwise specified.) PARAMETER NOTES and CONDITIONS NE12S0A0V/H20 Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage operation 4.5 13.8 Vdc Operating Te...

Page 3 - ELECTRICAL CHARACTERISTICS CURVES

Preliminary DS_NE12S20A_07272007 3 ELECTRICAL CHARACTERISTICS CURVES 55 60 65 70 75 80 85 90 95 1 2 4 6 8 10 12 14 16 18 20 Output current (A) Efficiency (%) 55 60 65 70 75 80 85 90 95 1 2 4 6 8 10 12 14 16 18 20 Output current (A) Efficiency (%) Figure 1: Converter efficiency vs. output current (0....

Page 6 - DESIGN CONSIDERATIONS; the signal is driven low; Safety Considerations; FEATURES DESCRIPTIONS; Enable; is the falling threshold; is the rising threshold that you want.

Preliminary DS_NE12S20A_07272007 6 DESIGN CONSIDERATIONS The NE12S0A0V(H)20 uses a single phase and voltagemode controlled buck topology. The output can betrimmed in the range of 0.59Vdc to 5.1Vdc by a resistorfrom Trim pin to Ground. The converter can be turned ON/OFF by remote controlwith positive...