Page 3 - Contents; About this Guide
Contents | 3 Contents 1 About this Guide Information symbols and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 The S55 System Introd...
Page 4 - Fans
4 | Contents www.dell.com | support.dell.com Install an AC or DC power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Replace an AC or DC power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6 Fans Components . . . . . . ....
Page 5 - FTOS; Information symbols and warnings; Table
About this Guide | 5 1 About this Guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting optional modules, and connecting to a power source. After you have completed the hardware installation and power-up of the S55, refer t...
Page 6 - Related publications; FTOS Configuration Guide for the S55 system
6 | About this Guide www.dell.com | support.dell.com Related publications For more information about the S55, refer to the following documents: • FTOS Configuration Guide for the S55 system • FTOS Command Reference for the S55 system • FTOS Release Notes for the S55 system NOTE: For the most recent ...
Page 7 - The S55 System; Introduction
The S55 System | 7 2 The S55 System Introduction The Dell Force10 S55 is a high performance, high capacity, low cost, stackable, Layer 2 switch/Layer 3 router that supports 44 built-in 10/100/1000 Base-T ports, four SFP (small form-factor pluggable) ports, and two optional module slots, and optional...
Page 8 - Orderable S55 systems; At least one grounded AC or DC power source per chassis
8 | The S55 System www.dell.com | support.dell.com Orderable S55 systems The S55 can be ordered in several different configurations. Optional modules are ordered separately. To successfully install the S55, ensure that you have the following: • S55 chassis (or multiple chassis, if stacking) • At lea...
Page 9 - Features; FTOS Command Reference for the S55; LED displays; Figure
The S55 System | 9 • Additional Fan module • Optional modules (if using) • Stacking cables, if stacking Features The S55 offers the following: • S55 CPU and switch processor • Up to 8 stacked units • Stackable switch features • 19-inch rack-mountable • Standard 1U chassis height • Hot Swappable opti...
Page 10 - The system LEDs are (
10 | The S55 System www.dell.com | support.dell.com Figure 2-3. Stack ID hexidecimal Display • The system LEDs are ( Figure 2-4 ): • Master (Stack Master status) • PSU1 (Power supply 1) • FAN1(Fan module 1) • ALM (System alarms) • SYS (System status) • PSU0 (Power supply 0) • FAN0 (Fan module 0) Fig...
Page 13 - Site Preparations; Site selection
Site Preparations | 13 3 Site Preparations The S55 is suitable for installation as part of a Common Bond Network (CBN). It can be installed in: • network telecommunication facilities • data centers • other locations where the National Electric Code (NEC) applies This chapter covers the following top...
Page 14 - Cabinet placement; The cabinet must meet the following criteria:; Rack mounting; Chapter 4, Install the S55; Fans and airflow; Normal is airflow from I/O panel to power supply; FTOS Command Reference; Power
14 | Site Preparations www.dell.com | support.dell.com Cabinet placement The S55 should be installed only in indoor cabinets designed for use in a controlled environment as described in the Site Selection heading. The S55 should not be installed in outside plant cabinets. The cabinet must meet the f...
Page 15 - Storing components; Follow these storage guidelines:
Site Preparations | 15 The system is powered-up as soon as the power cord is connected between the system and the power source. CAUTION: Always disconnect the power cable, before the power supply slots are serviced. CAUTION: The power supply cord is used as the main disconnect device on the AC and t...
Page 17 - Install the S55; Install the S55 chassis in a rack or cabinet; Attach mounting brackets
Install the S55 | 17 4 Install the S55 To install the S55 system, Dell Force10 recommends that you complete the installation procedures in the order presented below. Always handle the system and its components with care. Avoid dropping the S55 switch or its field replaceable units. 1 Install the S55...
Page 18 - Follow these steps to attach the brackets to the chassis:; Install chassis into rack or cabinet
18 | Install the S55 www.dell.com | support.dell.com Follow these steps to attach the brackets to the chassis: Install chassis into rack or cabinet Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access and airflow. Follow the steps below to install a swi...
Page 19 - Attach ground cable; Follow these steps to connect the ground cable to the chassis.
Install the S55 | 19 Attach ground cable The S55 is shipped with 1 10-32 screws for attaching a ground cable to the chassis. The cable itself is not included. Dell Force10 recommends a 6AWG one-hole lug, #10 hole size, 63" spacing (not included in shipping) to properly ground the chassis. The on...
Page 20 - Insert optional modules
20 | Install the S55 www.dell.com | support.dell.com Insert optional modules The S55 system has expansion slots, that can be used for stacking modules or for SFP+ devices.The SFP+ module can be inserted in either optional slot; the stacking module can only be inserted in the lower slot (OPT0). The m...
Page 21 - To install an optional module, follow the steps below:; Install the SFP and SFP+ optics
Install the S55 | 21 To install an optional module, follow the steps below: Install the SFP and SFP+ optics The S55 has 4 SFP optical ports in the PSU side of the chassis in addition to the optional SFP+ optical modules. To install SFP or SFP+ optics into an open port, follow the steps below: WARNIN...
Page 22 - Connect two S55s; transfer between the units.
22 | Install the S55 www.dell.com | support.dell.com The S55 supports stacking in either a ring or cascade topology. Dell Force10 recommends the ring topology when stacking S55 switches, to provide redundant connectivity. Figure 4-1. S55 stacking topology with 2-port 12G stacking module While the di...
Page 23 - Connect three or more S55s
Install the S55 | 23 Figure 4-2. 2 S55s with 2-port 12G stacking modules Connect three or more S55s 2-port 12G stacking modules As an option, when using the 2-port 12G stacking modules, insert a second cable into the other open stack ports, as shown in Figure 4-3 . The second cable provides both bac...
Page 24 - Supply power and power up the system; the equipment rack is properly mounted and grounded.; Power up sequence
24 | Install the S55 www.dell.com | support.dell.com Supply power and power up the system Supply power to the S55 after they are mounted in a rack (or on a table) and the optional modules are installed. Dell Force10 recommends re-inspecting your system prior to powering up. Verify that: • the equipm...
Page 25 - DC power; Hot-swap units in a stack
Install the S55 | 25 Figure 4-4. AC power connection DC power Connect the plug to each DC receptacle, making sure that the power cord is secure. As soon as the cable is connected between the S55 and the power source, the chassis is powered-up; there is no on/off switch. Figure 4-5. DC power connecti...
Page 26 - FTOS Configuration Guide
26 | Install the S55 www.dell.com | support.dell.com How units are identified within the stack is determined by the selected identification algorithm. The default algorithm has the units self-identify as Unit 0 through Unit [last] based on the order in which they come on-line. So, when setting up a ...
Page 27 - Power Supplies; Refer to; Components; The following power supply options are available for the S55:; Install an AC or DC power supply; for the
Power Supplies | 27 5 Power Supplies The S55 is designed to support two hot-swappable power supplies with integrated fans that provide the cooling for the chassis. There are two types of power supplies (AC or DC) and there are two air-flow directions (Normal and Reversed). Two power supplies are req...
Page 28 - To install a new power supply, follow the steps below:
28 | Power Supplies www.dell.com | support.dell.com NOTE: For a NEBS compliant installation, the AC power connections must use a surge protection device (SPD) to protect the AC power supplies from damage to excessive power line surges. NOTE: To comply with the GR-1089 Lightning Criteria for Equipmen...
Page 29 - Replace an AC or DC power supply; To replace a power supply, follow the steps below:
Power Supplies | 29 Replace an AC or DC power supply NOTE: If a power supply fails, it must be completely replaced. There are no field servicable components in the module itself. Refer to Chapter 9, Technical Support to request a hardware replacement. To replace a power supply, follow the steps belo...
Page 31 - Chapter 5, Power Supplies
Fans | 31 6 Fans The S55 comes from the factory with 1 power supply and 2 fan modules installed in the chassis. Both the fan module and the integrated fan-power supply are hot-swappable if a second (redundant) power supply is installed and running. With redundant power supplies, traffic will not be ...
Page 32 - To install a new fan module, follow the steps below:; Replace a fan module; To replace a fan module, follow the steps below.; Grab Handle
32 | Fans www.dell.com | support.dell.com Figure 6-1. Replacing the fan module To install a new fan module, follow the steps below: Replace a fan module To replace a fan module, follow the steps below. Step Task 1 Take the fan module out of the shipping box. 2 Using the grab handle, slide the module...
Page 33 - Access the console ports; To access the console port, follow the procedures below. Refer to
Access the console ports | 33 7 Access the console ports The S55 system can be accessed directly through the console port at I/O side of the switch. Access the RJ45 console port (RS-232) NOTE: Before starting this procedure, be sure you have a terminal emulation program already installed on your PC....
Page 34 - Access the RJ-45 console port with a DB-9 adapter; lists the pin assignments.; Access the USB-B console port
34 | Access the console ports www.dell.com | support.dell.com Access the RJ-45 console port with a DB-9 adapter You can connect to the console using an RJ-45 to DB-9 adapter along with the RJ-45 rollover cable if the DTE has a DB-9 interface. Table 7-1 lists the pin assignments. Access the USB-B con...
Page 37 - S55 Specifications; This chapter contains these major sections:; Chassis Physical Design; Environmental Parameters
S55 Specifications | 37 8 S55 Specifications This chapter contains these major sections: • Chassis Physical Design • Agency Compliance Chassis Physical Design Environmental Parameters AC Power Requirements Parameter Specifications Height 1.73 inches (4.4 cm) Width 17.32 inches (44.0 cm) Depth 18.74 ...
Page 38 - DC Power Requirements; Agency Compliance; NEBS (Network Equipment Building Systems) Compliance
38 | S55 Specifications www.dell.com | support.dell.com DC Power Requirements IEEE Standards The S55 complies with the following IEEE standards: • 802.3ae 10 Gigabit Ethernet • 802.3ab 1000Base-T • 802.1p L2 Prioritization • 802.1Q VLAN Tagging, Double VLAN Tagging (Q in Q), GVRP • 802.1s Multiple S...
Page 40 - Germany
40 | S55 Specifications www.dell.com | support.dell.com WARNING: This is a Class A product. In a domestic environment, this device may cause radio interference, in which case, the user may be required to take adequate measures. Figure 8-4. European Community Contact Dell Force10, EMEA - Central Dahl...
Page 41 - Safety Standards and Compliance Agency Certifications
S55 Specifications | 41 Figure 8-6. Korea Information Figure 8-7. Korea Compliance Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 1st Edition • CSA 60950-1-03, 2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition • EN 60825-1 Safety of Laser Products—Part 1: Equip...
Page 42 - Product Recycling and Disposal
42 | S55 Specifications www.dell.com | support.dell.com Immunity • EN 300 386 v1.3.3: 2005 EMC for Network Equipment • EN55022 2006, Class A • EN 55024 1998 + A1: 2001 + A2: 2003 • EN 61000-3-2 Harmonic Current Emissions • EN 61000-3-3 Voltage Fluctuations and Flicker • EN 61000-4-2 ESD • EN 61000-4...
Page 43 - Remove the small screw at the top of the SD card slot.
S55 Specifications | 43 Dell Force10 products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE. For information on Dell Force10 product recycling offerings, see the WEEE Recycling instructions on iSupport at: https://w...
Page 44 - Gently lift the battery from the board.; Perchlorate Material; — Special handling may apply.
44 | S55 Specifications www.dell.com | support.dell.com 2 Slide the top backwards until its front flange slides free of the faceplate, then lift it off. 3 Gently lift the battery from the board. Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/EC concern...
Page 45 - Technical Support; The iSupport website; Accessing iSupport services
Technical Support | 45 9 Technical Support This appendix contains these major sections: • The iSupport website • Contacting the Technical Assistance Center • Requesting a hardware replacement The iSupport website iSupport provides a range of documents and tools to assist you with effectively using D...
Page 46 - Contacting the Technical Assistance Center; To request replacement hardware, follow these steps:
46 | Technical Support www.dell.com | support.dell.com Contacting the Technical Assistance Center Requesting a hardware replacement To request replacement hardware, follow these steps: How to Contact Dell Force10 TAC Log in to iSupport at http://www.force10networks.com/support/ and select the Servic...