Page 3 - Contents
Contents 1 About your Dell PowerEdge M830.................................................................... 8 Front panel features and indicators—PowerEdge M830 ..................................................................... 8 Using USB diskette or USB DVD/CD drives ............................
Page 8 - About your Dell PowerEdge M830; Front panel features and indicators—PowerEdge M830
1 About your Dell PowerEdge M830 The Dell PowerEdge M830 is a full-height blade that is configured for the PowerEdge M1000e enclosure. It supports up to four processors based on the Intel Xeon E5-4600 v3 family, up to 48 DIMMs, up to four hard drives/SSDs and twelve SSDs. The M830 systems are availa...
Page 9 - Using USB diskette or USB DVD/CD drives
Item Indicator, Button, or Connector Icon Description 1 Hard drives/SSDs 2.5 inch hard drive system Four 2.5 inch hot-swap SAS/SATA/PCIe SSDs or SAS/SATA hard-drives. 1.8 inch SSD system Twelve 1.8 inch hot-swap SAS SSDs. 2 USB2 connector Allows a USB device to be connected to the system. 3 USB1/iDR...
Page 11 - iDRAC Direct LED indicator codes
Drive-Status Indicator Pattern Condition Blinks green three seconds, amber three seconds, and off six seconds Rebuild aborted iDRAC Direct LED indicator codes NOTE: The iDRAC Direct LED indicator does not light up for the USB mode. Figure 4. iDRAC Direct LED indicator 1. iDRAC Direct status indicato...
Page 12 - Documentation matrix
iDRAC Direct LED indicator pattern Condition Steady green for two seconds Indicates that the system is connected. Flashing green (on for two seconds and off for two seconds) Indicates that the system connected is recognized. Turns off Indicates that the system is unplugged. Documentation matrix The ...
Page 13 - Quick Resource Locator
To... Refer to... Know the features of the storage controller cards, deploy the cards, and manage the storage subsystem Storage controller documentation at dell.com/ storagecontrollermanuals See the event and error messages generated by the system firmware and agents that monitor system components D...
Page 14 - Performing initial system configuration; Setting up your system; Setting up and configuring the iDRAC IP address
2 Performing initial system configuration After you receive your PowerEdge system, you must set up your system in the enclosure, install the operating system if it is not pre-installed, and set up and configure the system iDRAC IP address. Setting up your system 1. Unpack the blade. 2. Remove the I/...
Page 15 - Logging in to iDRAC; Installing the operating system
For more information on setting up and configuring iDRAC, see the iDRAC User’s Guide at dell.com/ esmmanuals . Logging in to iDRAC You can log in to iDRAC as an iDRAC user, a Microsoft Active Directory user, or a Lightweight Directory Access Protocol (LDAP) user. You can also log in using Single Sig...
Page 17 - Navigation keys; About System Setup
3 Pre-operating system management applications The pre-operating system management applications for your system helps you manage different settings and features without booting to the operating system.Your system has the following pre-operating system management applications:• System Setup• Boot Man...
Page 20 - Processor Settings screen
Menu Item Description System Memory Testing Specifies whether system memory tests are run during system boot. Options are Enabled and Disabled . By default, the System Memory Testing option is set to Disabled . Memory Operating Mode Specifies the memory operating mode. The options available are Opti...
Page 21 - SATA Settings screen
Menu Item Description option is set to Enabled . You can disable this option for applications that require high utilization of random memory access. Hardware Prefetcher Enables or disables the hardware prefetcher. By default, the Hardware Prefetcher option is set to Enabled . DCU Streamer Prefetcher...
Page 25 - Integrated Devices screen
Menu Item Description PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI boot option is created for the device. PXE Device n Settings (n = 1 to 4) Allows you to control the configuration of the PXE device. Integrated Devices screen Integrated Devices screen allows you to ...
Page 26 - Serial Communication screen
Menu Item Description Memory Mapped I/O above 4GB Allows you to enable support for PCIe devices that require large amounts of memory. By default, the option is set to Enabled . Slot Disablement Allows you to enable or disable available PCIe slots on your system. The Slot Disablement feature controls...
Page 27 - System Profile Settings screen
Menu Item Description Redirection After Boot Enables or disables the BIOS console redirection when the operating system is loaded. By default, the Redirection After Boot option is set to Enabled . System Profile Settings screen You can use the System Profile Settings screen to enable specific system...
Page 28 - System Security Settings screen
Menu Item Description Energy Efficient Policy Enables you to select the Energy Efficient Policy . The CPU uses the setting to manipulate the internal behavior of the processor and determines whether to target higher performance or better power savings. Number of Turbo Boot Enabled Cores for Processo...
Page 30 - Miscellaneous Settings screen
Miscellaneous Settings screen You can use the Miscellaneous Settings screen to perform specific functions such as updating the asset tag, and changing the system date and time.To view the Miscellaneous Settings screen, click System Setup Main Menu → System BIOS → Miscellaneous Settings . Menu Item D...
Page 31 - About Boot Manager; Entering Boot Manager; About Dell Lifecycle Controller
About Boot Manager Boot Manager enables you to add, delete, and arrange boot options. You can also access System Setup and boot options without restarting the system. Entering Boot Manager The Boot Manager screen enables you to select boot options and diagnostic utilities. 1. Turn on or restart your...
Page 35 - Entering the iDRAC Settings utility
Entering the iDRAC Settings utility 1. Turn on or restart the managed system. 2. Press <F2> during Power-on Self-test (POST). 3. In the System Setup Main Menu page, click iDRAC Settings . The iDRAC Settings page is displayed. 35
Page 36 - Customer and field replaceable units—PowerEdge M830
4 Installing and removing blade components This section provides information on installing and removing the blade components. For information on installing and removing the enclosure components, see the enclosure Owner's Manual at dell.com/ poweredgemanuals . Customer and field replaceable units—Pow...
Page 37 - After working inside your system; Removing and installing a blade
Safety instructions CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is no...
Page 38 - Removing the blade
Removing the blade Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servici...
Page 39 - Installing a blade
Figure 5. Removing or installing the blade 1. release button 2. blade 3. enclosure Related Links Installing a blade Installing a blade Prerequisites Ensure that you read the Safety instructions . CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubl...
Page 40 - Removing and installing the system cover; Removing the system cover
Related Links Removing the blade Removing and installing the system cover Removing the system cover Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as di...
Page 41 - Installing the system cover
Figure 6. Removing and installing the system cover 1. system cover 2. release button (2) 3. I/O connector cover (2) 4. alignment guides on the system cover and the chassis Next steps Install the system cover. Related Links Installing the system coverRemoving the blade Installing the system cover Pre...
Page 43 - Inside the blade
Inside the blade Figure 7. Inside the blade 1. mezzanine card connectors for card 1 and card 2 2. restore Serial Peripheral Interface (rSPI) card 3. mezzanine card connectors for card 3 and card 4 4. Network Daughter Card (NDC) 5. memory module (42) 6. processor 2 7. cooling shroud 8. processor 3 9....
Page 44 - Cooling shroud; Removing the cooling shroud
Cooling shroud Removing the cooling shroud Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support tea...
Page 45 - Installing the cooling shroud; Processor blank and DIMM blank; Removing a processor blank and DIMM blank
Removing the system cover Installing the cooling shroud Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service an...
Page 46 - Installing a processor blank and DIMM blank
Steps Hold the processor blank and DIMM blank by its edges and lift it away from the system. Figure 9. Removing and installing a processor blank and DIMM blank 1. processor blank and DIMM blank 2. heat sink retention socket (4) 3. standoff (4) Next steps 1. Install the heat sink and the processor. 2...
Page 47 - System memory
Steps1. Align the standoffs on the processor blank and DIMM blank with the heat sink retention sockets on the processor socket. 2. Lower the processor blank and DIMM blank onto the system until the standoffs on the processor blank and DIMM blank engage with the heat sink retention sockets. Next step...
Page 49 - General memory module installation guidelines
channel 3: memory sockets B4, B8, and B12 Processor 3 channel 0: memory sockets C1, C5, and C9 channel 1: memory sockets C2, C6, and C10 channel 2: memory sockets C3, C7, and C11 channel 3: memory sockets C4, C8, and C12 Processor 4 channel 0: memory sockets D1, D5, and D9 channel 1: memory sockets ...
Page 50 - Mode-specific guidelines
dual-rank DIMMs in the sockets with white release tabs and single-rank DIMMs in the sockets with black release tabs. • In a dual- or four-processor configuration, the memory configuration for each processor must be identical. For example, if you populate socket A1 for processor 1, then you must popu...
Page 51 - Removing memory modules
Memory optimized (independent channel) mode This mode supports SDDC only for memory modules that use x4 device width, and this mode does not impose any specific slot population requirements. Memory sparing NOTE: To use memory sparing, this feature must be enabled in System Setup. In this mode, one r...
Page 52 - Installing memory modules
2. Follow the procedure listed in Before working inside your system . 3. Remove the cooling shroud. Steps1. Locate the appropriate memory-module socket(s). 2. To release the memory module from the socket, simultaneously press the ejectors on both ends of the memory-module socket. CAUTION: Handle eac...
Page 53 - Sample memory configurations
NOTE: You must remove a memory module to upgrade a memory module or replace a faulty memory module. 1. Ensure that you read the Safety instructions . 2. Follow the procedure listed in Before working inside your system . 3. If installed, remove the memory module or the memory-module blank. WARNING: T...
Page 56 - I/O module mezzanine cards; Mezzanine card installation guidelines
System capacity (in GB) DIMM size (in GB) Number of DIMMs Organization and speed DIMM slot population 256 16 16 2R x4, 2133 MT/s A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 384 16 24 2R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6, C1, C2, C3, C4, C5, C6, D1, D2, D...
Page 57 - Removing a mezzanine card
Removing a mezzanine card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to ...
Page 58 - Installing a mezzanine card
Next steps 1. Install the mezzanine card. Related Links Installing a mezzanine cardRemoving the bladeRemoving the system cover Installing a mezzanine card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repair...
Page 59 - Mezzanine card support bracket; Removing the mezzanine card support bracket
Mezzanine card support bracket Removing the mezzanine card support bracket Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or t...
Page 60 - Installing the mezzanine card support bracket
Figure 13. Removing and installing the mezzanine card support bracket 1. screw 2. mezzanine card support bracket 3. tab on the bracket (2) 4. slot on the system (2) 5. system board Next steps 1. Install the mezzanine card support bracket. Related Links Installing the mezzanine card support bracket I...
Page 61 - Replacing an SD card
Steps1. Orient the mezzanine card support bracket toward the back of the system. 2. Align the tabs on the mezzanine card support bracket with the slots on the system and slide it until the tabs on the support bracket engage with the slots on the system. 3. Install the screw to secure the mezzanine c...
Page 62 - Internal USB key
Figure 14. Replacing an SD card 1. IDSDM card 2. SD card 3. upper card slot (SD 2) 4. lower card slot (SD 1) Next steps 1. Follow the procedure listed in After working inside your system . 2. Enter the System Setup and ensure that the Internal SD Card Port and Internal SD Card Redundancy modes are e...
Page 64 - Removing the IDSDM card
Removing the IDSDM card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to se...
Page 65 - Installing the IDSDM card
Figure 16. Removing and installing the IDSDM card 1. IDSDM card 2. screw (2) 3. SD card slot bracket 4. mezzanine card support bracket 5. connector 6. standoff (2) Next steps 1. Install the IDSDM card. Related Links Removing a mezzanine cardReplacing the internal USB keyReplacing an SD cardInstallin...
Page 66 - Removing the rSPI card
3. Remove the IDSDM card. CAUTION: To prevent damage to the IDSDM card, hold the card only by its edges. NOTE: You must remove the IDSDM card to replace a faulty IDSDM card or service other components inside the system. Steps1. Align the following:• The slot on the card edge with the projection tabs...
Page 67 - Installing the rSPI card
CAUTION: To prevent damage to the rSPI card, hold the card only by its edges. 2. Lift the card away from the system. Figure 17. Removing and installing the rSPI card 1. screw (2) 2. rSPI card 3. standoff (2) 4. connector Next steps 1. Install the rSPI card. Related Links Installing the rSPI cardRemo...
Page 68 - SD vFlash card; Replacing the SD vFlash card
CAUTION: To prevent damage to the rSPI card, hold the card only by its edges. NOTE: You must remove the rSPI card to replace a faulty rSPI card or service other components inside the system. Steps1. Align the two screw holes on the rSPI card with the standoffs on the system board. 2. Install the two...
Page 69 - Network Daughter Card; Removing the Network Daughter Card
Figure 18. Replacing the SD vFlash card 1. SD vFlash card 2. SD vFlash card slot 3. SD vFlash card slot identification label Next steps Follow the procedure listed in After working inside your system . Network Daughter Card Removing the Network Daughter Card Prerequisites CAUTION: Many repairs may o...
Page 71 - Installing the Network Daughter Card; Processors
Removing a mezzanine card Installing the Network Daughter Card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone ser...
Page 72 - Removing a heat sink
• Installing an additional processor• Replacing a processor Removing a heat sink Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the onlin...
Page 73 - Removing a processor
Figure 20. Removing and installing a heat sink 1. retention screw (4) 2. heat sink 3. processor socket 4. heat sink retention socket (4) Next steps 1. Install the heat sink. Related Links Removing the cooling shroudRemoving a processor Removing a processor Prerequisites WARNING: The processor will b...
Page 76 - Installing a processor
Installing a processor Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to ser...
Page 77 - Installing a heat sink
Removing a processor blank and DIMM blankInstalling a heat sink Installing a heat sink Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the...
Page 79 - Hard drive/SSD bay numbering
Hard drives/SSDs Your system supports up to four 2.5 inch SAS/SATA/PCIe SSDs or SAS /SATA hard drives and twelve 1.8 inch SAS SSDs. The hard drives/SSDs are supplied in special hot-swappable drive carriers that fit in the drive bays and these drives connect to the system board through the hard-drive...
Page 80 - Hard drive/SSD installation guidelines
Figure 26. SSD bay numbering — 1.8 inch SSD system Hard drive/SSD installation guidelines For single hard drive configuration, a hard drive blank must be installed in the other drive bay to maintain proper cooling airflow. Removing a hard drive/SSD Prerequisites CAUTION: Many repairs may only be don...
Page 81 - Installing a hard drive/SSD
Figure 27. Removing and installing a hard drive/SSD 1. release button 2. hard drive/SSD connector (on backplane) 3. hard drive/SSD 4. hard drive/SSD carrier handle Next steps 1. If you are removing a hard drive/SSD permanently, install the hard drive/SSD blank. If you are installing a new hard drive...
Page 82 - Removing a hard drive/SSD blank
The status LED indicator displays a steady green light if the drive is installed correctly. The drive carrier LED green indicator flashes as the drive rebuilds. Removing a hard drive/SSD blank Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only per...
Page 83 - Installing a hard drive/SSD blank; Shutdown procedure for servicing a hard drive/SSD
Figure 29. Removing and installing a 1.8 inch SSD blank 1. SSD blank 2. release latch Next steps 1. Install the hard drive/SSD. See Installing a hard drive/SSD . Installing a hard drive/SSD blank Prerequisites 1. Ensure that you read the Safety instructions . 2. Remove a hard drive/SSD. See Removing...
Page 85 - Removing a 1.8 inch SSD from a 1.8 inch SSD carrier
Installing a 2.5 inch hard drive/SSD in a 2.5 inch hard drive/SSD carrier Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or te...
Page 86 - Installing a 1.8 inch SSD in a 1.8 inch SSD carrier
Steps Pull the rails on the side of the carrier and lift the SSD out of the carrier. Figure 31. Removing and installing a 1.8 inch SSD in a 1.8 inch SSD carrier 1. SSD carrier 2. SSD Next steps Install a 1.8 inch SSD in a 1.8 inch SSD carrier. See Installing a 1.8 inch SSD in a 1.8 inch SSD carrier ...
Page 87 - Removing a hard drive/SSD cage
Steps Insert the SSD into the SSD carrier with the connector end of the SSD toward the back. When aligned correctly, the back of the SSD is flush with the back of the SSD carrier. Hard drive/SSD cage Removing a hard drive/SSD cage Prerequisites CAUTION: Many repairs may only be done by a certified s...
Page 88 - Installing a hard drive/SSD cage
Figure 32. Removing and installing a hard drive/SSD cage 1. hard drive/SSD cage 2. screw (5) 3. guide pin (5) 4. screw hole on the chassis (4) 5. standoff (2) Next steps 1. Install the hard drive/SSD cage. Related Links Installing a hard drive/SSD cageRemoving the bladeRemoving the system cover Inst...
Page 89 - Hard drive/SSD backplane
1. Ensure that you read the Safety instructions . 2. Keep the #1 Phillips screwdriver ready. 3. Remove the hard drive/SSD cage. NOTE: You must remove the hard drive/SSD cage to replace a faulty hard drive/SSD cage or service other components inside the system. Steps1. Align the screw holes on the ha...
Page 95 - backplane
Removing a 2.5 inch (x2) SATA hard drive/SSD plus 2.5 inch (x2) PCIe SSD backplane Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the onl...
Page 101 - NVRAM backup battery; Replacing the NVRAM backup battery
NVRAM backup battery The NVRAM backup battery installed in your system helps to retain the BIOS settings and configurations even if the power is switched off. Replacing the NVRAM backup battery Prerequisites WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replac...
Page 102 - Storage controller card
Figure 37. Replacing the NVRAM backup battery 1. negative side of battery connector 2. positive side of battery Next steps 1. If applicable, install the memory module. 2. Install the following: a. hard drive/SSD cage b. hard drive/SSD backplane c. hard drive/SSD 3. Follow the procedure listed in Aft...
Page 103 - Removing the storage controller card
Removing the storage controller card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Dam...
Page 105 - Installing the storage controller card
Installing the storage controller card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. D...
Page 106 - Expander card; Removing an expander card
Expander card Removing an expander card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. ...
Page 108 - Installing an expander card
Installing an expander card Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due t...
Page 109 - System board; Removing the system board
System board Removing the system board Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. D...
Page 112 - Installing the system board
Installing the system board Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due t...
Page 114 - Trusted Platform Module; Installing the Trusted Platform Module
NOTE: You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct Service Tag. Once the Service Tag is entered, it cannot be updated or changed. 5. Click Ok . 6. Import your new or existing iDRAC Enterprise license.For more information, see Integrated De...
Page 115 - Re-enabling the TPM for BitLocker users
Figure 42. Installing the TPM 1. TPM 2. TPM connector 3. guide pin on the TPM connector 4. plastic bolt 5. slot on the system board Re-enabling the TPM for BitLocker users Initialize the TPM.For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/ cc753140.aspx ....
Page 116 - Troubleshooting your system; Safety first—for you and your system; Troubleshooting system memory
5 Troubleshooting your system Safety first—for you and your system CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and s...
Page 117 - Troubleshooting hard drives; Troubleshooting Solid State Drives
8. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.If the test fails, see Getting Help . Troubleshooting hard drives Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repa...
Page 118 - Troubleshooting USB devices; Troubleshooting an internal SD card
3. Restart the blade, enter the System Setup and confirm that the drive controller is enabled. 4. Ensure that any required device drivers are installed and are configured correctly. NOTE: Installing a SSD into another bay may break the mirror if the mirror state is optimal. 5. Remove the SSD and ins...
Page 119 - Troubleshooting processors; Troubleshooting the blade system board
c. Install a new SD card in slot 2. 5. If the Internal SD Card Redundancy option in the Integrated Devices screen of the System Setup is set to Mirror mode and SD card 2 has failed, insert the new SD card into SD card slot 2. 6. If the Internal SD Card Redundancy option in Integrated Devices screen ...
Page 120 - Troubleshooting the NVRAM backup battery; System messages; Warning messages
Troubleshooting the NVRAM backup battery Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team....
Page 121 - Diagnostic messages; Alert messages
Diagnostic messages The system diagnostic utilities may issue messages if you run diagnostic tests on your system. For more information about system diagnostics, see Using system diagnostics . Alert messages The systems management software generates alert messages for your system. Alert messages inc...
Page 122 - Dell Online Diagnostics; Dell Embedded System Diagnostics; When to use the Embedded System Diagnostics
6 Using system diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unabl...
Page 123 - Running the Embedded System Diagnostics; System diagnostic controls
Running the Embedded System Diagnostics The embedded system diagnostics program is run from the Dell Lifecycle Controller. Prerequisites CAUTION: Use the embedded system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages. Steps1. A...
Page 124 - Jumpers and connectors; System board jumper settings
7 Jumpers and connectors System board jumper settings CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. ...
Page 125 - System board connectors
System board connectors Figure 43. System board connectors Table 5. System board connectors Item Connector Description 1 MEZZ1_FAB_C1 mezzanine card connector for the expansion bus 2 MEZZ2_FAB_B1 mezzanine card connector for the expansion bus 3 VFLASH SD vFlash card connector 4 bNDC Network daughter...
Page 126 - Disabling a forgotten password
Item Connector Description 9 TPM TPM connector 10 B1, B2, B5, B6, B9, B10 Memory module sockets (processor 2) 11 CPU2 Processor socket 2 12 B3, B4, B7, B8, B11, B12 Memory module sockets (processor 2) 13 C3, C4, C7, C8, C11, C12 Memory module sockets (processor 3) 14 CPU3 Processor socket 3 15 C1, C...
Page 128 - Technical specifications—PowerEdge
8 Technical specifications—PowerEdge M830 Physical Height 39.52 cm (15.56 inch) Width 5.03 cm (1.98 inch) Depth 54.5 cm (21.45 inch) Weight (maximum) 14.5 kg (31.9 lb) Processor Processor type up to four Intel Xeon E5-4600 v3 product family processors Memory Architecture 2133 MT/s, 1600 MT/s, 1333 M...
Page 133 - Getting help; Contacting Dell
9 Getting help Contacting Dell Prerequisites NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. About this task Dell provides several online and telephone-based support and service options. A...