Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX- User Manual
Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Contents
- Page 45 – Introduction
- Page 47 – AMP Event Messages
- Page 59 – ASR Event Messages
- Page 67 – BAT Event Messages
- Page 97 – BOOT Event Messages
- Page 99 – CBL Event Messages
- Page 105 – CMC Event Messages
- Page 139 – CPU Event Messages
- Page 159 – CPUA Event Messages
- Page 161 – CTL Event Messages
- Page 207 – DKM Event Messages
- Page 211 – ENC Event Messages
- Page 229 – FAN Event Messages
- Page 241 – FCD Event Messages
- Page 245 – HWC Event Messages
- Page 291 – IOV Event Messages
- Page 317 – JCP Event Messages
- Page 325 – LC Event Messages
- Page 333 – LIC Event Messages
- Page 355 – LNK Event Messages
- Page 359 – LOG Event Messages
- Page 363 – MEM Event Messages
- Page 393 – OSE Event Messages
- Page 403 – PCI Event Messages
- Page 427 – PDR Event Messages
- Page 497 – PST Event Messages
- Page 509 – PSU Event Messages
- Page 547 – PSUA Event Messages
- Page 549 – PWR Event Messages
- Page 619 – RAC Event Messages
- Page 625 – RDU Event Messages
- Page 645 – RED Event Messages
- Page 649 – RFL Event Messages
- Page 655 – RFLA Event Messages
- Page 657 – RFM Event Messages
- Page 667 – RRDU Event Messages
- Page 671 – SEC Event Messages
- Page 689 – SEL Event Messages
- Page 713 – STOR Event Messages
- Page 747 – SUP Event Messages
- Page 753 – SWC Event Messages
- Page 789 – SWU Event Messages
- Page 815 – SYS Event Messages
- Page 819 – TMP Event Messages
- Page 847 – USR Event Messages
- Page 857 – VDR Event Messages
- Page 893 – VFL Event Messages
- Page 903 – VFLA Event Messages
- Page 905 – VLT Event Messages
Dell PowerEdge VRTX Chassis Management
Controller Firmware
Event Message Reference
Guide
Version 1.0
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Contents 1 Introduction................................................................................................................................ 45 2 AMP Event Messages.............................................................................................................. 47 AMP0300 ......
1 Introduction The Event Message Reference contains the error and event information generated by firmware and other agents that monitor system components. These events might be logged, presented to the user on one of the system management consoles, or both logged and displayed. Each event consists o...
2 AMP Event Messages AMP0300 Message The system board arg1current is less than the lower warning threshold. Arguments • arg1 = name Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes....
3 ASR Event Messages ASR8500 Message Watchdog timer is disabled. Detailed Description Watchdog timer is disabled. The watchdog timer is an internal mechanism used to monitor the health of the Chassis Management Controller. The watchdog timer could be disabled as part of a troubleshooting operation a...
4 BAT Event Messages BAT1000 Message Battery on arg1is missing. Arguments • arg1 = controller name Detailed Description The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message. Recommended...
5 BOOT Event Messages BOOT8500 Message Unable to change the BIOS boot order for the Server arg1 Arguments • arg1 = slot number Detailed Description Unable to change the BIOS boot order for the server because of a broken communication between the CMC and iDRAC, or iDRAC is rebooting. Recommended Resp...
6 CBL Event Messages CBL8500 Message SAS cable arg1to expanderarg2is not connected. Arguments • arg1 = cable id • arg2 = expander id Detailed Description SAS cables are not connected to the expander correctly. Recommended Response Action Check whether or not the SAS cables are connected to the expan...
7 CMC Event Messages CMC8501 Message Chassis Group Leader has synchronized this members configuration. Detailed Description Multi Chassis Management feature on CMC allows for pushing the lead chassis configuration data to its members. This message appears in the members log when the configuration da...
8 CPU Event Messages CPU0000 Message CPU arg1has an internal error (IERR). Arguments • arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Review System Event Log and Operating System Logs. If the i...
9 CPUA Event Messages CPUA0023 Message CPU arg1is absent Arguments • arg1 = number Detailed Description None Recommended Response Action Verify processor installation. If present, reseat the processor. Category System Health SubCategory CPUA = Proc Absent Severity Severity 1 (Critical) Trap/EventID ...
10 CTL Event Messages CTL1 Message Controller event log: arg1 Arguments • arg1 = message Detailed Description This event is retrieved from the controller when iDRAC storage monitoring was not running. Such events which are generated in the past are logged as informational severity. Recommended Respo...
11 DKM Event Messages DKM1000 Message A network problem detected. Cannot contact key management server. Detailed Description None Recommended Response Action Check for network connectivity. Review network, server, and client configuration. Category System Health SubCategory DKM = Dell Key Mngr Sever...
12 ENC Event Messages ENC40 Message A new enclosure was detected on arg1. Arguments • arg1 = controller name Detailed Description The controller detected a new enclosure. This is due either to a hot plug of an enclosure, or a power state change of an enclosure. In addition, this message is generated...
13 FAN Event Messages FAN8500 Message Enhanced Cooling Mode is Enabled Detailed Description Enabling Enhanced Cooling Mode will provide increased airflow capability to the blades by increasing the maximum allowable blower speed at the cost of increased power consumption. Recommended Response Action ...
14 FCD Event Messages FCD8500 Message Unable to apply the arg1configuration. The affected servers (slotarg2) are not turned off. Arguments • arg1 = configuration name • arg2 = slot number Detailed Description The server specified in the message must be turned off or the server slot must be empty bef...
15 HWC Event Messages HWC8502 Message The KVM interconnect is connected. Detailed Description The KVM cable is connected. Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Mes...
16 IOV Event Messages IOV000 Message Successfully completed the operation. Detailed Description This operation was successful. Recommended Response Action No response action is required. Category Configuration SubCategory IOV = IO Virtualization Severity Severity 3 (Informational) Trap/EventID FALSE...
17 JCP Event Messages JCP8501 Message Job ID: arg1. CMC sentarg2ofarg3arg4profilesarg5arg6properties to the server (Service Tag: arg7) in the slotarg8. Arguments • arg1 = job ID • arg2 = number of applied settings • arg3 = number of available settings • arg4 = profile name • arg5 = profile type • ar...
18 LC Event Messages LC054 Message Unable to write to the network share. Detailed Description The network share may be read-only or it may not have sufficient space for the export operation.. Recommended Response Action Verify the network share is not read-only and has sufficient space for exporting...
19 LIC Event Messages LIC501 Message A required license is missing or expired. Detailed Description The attempted action requires a valid license for certain advanced features installed in the system but the required license is missing or expired. Recommended Response Action Obtain an appropriate li...
20 LNK Event Messages LNK8500 Message Network link to servers in slot arg1IOMarg2portarg3is down Arguments • arg1 = slot id • arg2 = iom id • arg3 = port id Detailed Description Internal sled network connection is down Recommended Response Action Remove and re-insert the sled Category System Health ...
21 LOG Event Messages LOG004 Message Resource allocation failure. Detailed Description The operation failed due to lack of memory or file space in iDRAC. Recommended Response Action Reset iDRAC and retry the operation. Category Configuration SubCategory LOG = Log event Severity Severity 1 (Critical)...
22 MEM Event Messages MEM8500 Message Low memory condition detected. Detailed Description A low memory condition was detected. If this condition continues, a failover or a reset may occur. If multiple resets occur, contact your service provider. Recommended Response Action If multiple resets occur, ...
23 OSE Event Messages OSE0000 Message A critical stop occurred during OS load. Detailed Description The system halted due to an exception during operating system load or operating system initialization. Recommended Response Action Review operating system logs and system video for additional informat...
24 PCI Event Messages PCI1300 Message A front panel diagnostic interrupt was detected. Detailed Description The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced. Recommended Response Action Reset the system to continue operation. Category S...
25 PDR Event Messages PDR1 Message arg1copyback stopped for rebuild. Arguments • arg1 = physical disk Detailed Description This message is generated after a copyback stops on a physical disk during a rebuild operation. Recommended Response Action Wait for rebuild to finish, then copyback should resu...
26 PST Event Messages PST0128 Message No memory is detected. Detailed Description System BIOS was unable to detect memory in the system . This exception occurred early in system power on, thus the system may not display video (BIOS Post Exception 80). Recommended Response Action Inspect System Memor...
27 PSU Event Messages PSU8501 Message Unable to retrieve PSU arg1input voltage information. Arguments • arg1 = slot number Detailed Description Unable to retrieve input voltage information for the PSU specified in the message. Recommended Response Action Remove the PSU from the chassis, wait for two...
28 PSUA Event Messages PSUA0016 Message Power supply arg1is absent. Arguments • arg1 = number Detailed Description The supply has been removed or has failed. Recommended Response Action Install the power supply if needed. Category System Health SubCategory PSUA = PSU Absent Severity Severity 1 (Crit...
29 PWR Event Messages PWR8500 Message Chassis power state updated to arg1fromarg2. Arguments • arg1 = new power state • arg2 = old power state Detailed Description The chassis power state from the configuration database and the current state are different. The current chassis power state will be upd...
30 RAC Event Messages RAC038 Message Unable to perform the operation due to an unknown error in iDRAC. Detailed Description The operation failed to run due to an unknown error in iDRAC. Recommended Response Action Retry the action. If this fails, reset iDRAC. Category Configuration SubCategory RAC =...
31 RDU Event Messages RDU8500 Message CMC arg1: active Arguments • arg1 = slot number Detailed Description The CMC is identified in the message is active. Recommended Response Action No response action is required. Category Audit SubCategory RDU = Redundancy Severity Severity 3 (Informational) Trap/...
32 RED Event Messages RED001 Message Job completed successfully. Detailed Description Job completed successfully. Recommended Response Action No response action is required. Category Updates SubCategory RED = FW Download Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD messa...
33 RFL Event Messages RFL2000 Message Internal Dual SD Module arg1is present. Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD ...
34 RFLA Event Messages RFLA2001 Message Internal Dual SD Module arg1is absent. Arguments • arg1 = name Detailed Description The SD card module is not detected or not installed. Recommended Response Action If unintended, reinstall the SD module. Category System Health SubCategory RFLA = IDSDM Absent ...
35 RFM Event Messages RFM1018 Message Removable Flash Media is absent. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message displ...
36 RRDU Event Messages RRDU0001 Message Internal Dual SD Module is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD mes...
37 SEC Event Messages SEC0001 Message The drive bay is open. Detailed Description The drive bay is open. A drive may be added or removed. System performance may be degraded. Recommended Response Action Close the drive bay. Check system logs. Category System Health SubCategory SEC = Security Event Se...
38 SEL Event Messages SEL0002 Message Logging is disabled. Detailed Description This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h) Recommended Response Action If unintended, re-enable logging. Category System Health SubCategor...
39 STOR Event Messages STOR1 Message A device arg1is in an unknown state. Arguments • arg1 = device name Detailed Description The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable, or a missing device, or a problem with the d...
40 SUP Event Messages SUP001 Message Insufficient parameters provided. Detailed Description Insufficient Parameters provided for the WSMAN command. Recommended Response Action Make sure the parameters are correct and in the right number and format and retry the action. Category Updates SubCategory S...
41 SWC Event Messages SWC8533 Message Unable to complete delete all keys operation for service accounts for all slots due to problem saving key file. Detailed Description The delete all keys for service accounts for all slots operation did not complete successfully due to problems encounterered whil...
42 SWU Event Messages SWU8500 Message The schedule to arg1Lifecycle Controller on serverarg2was not successful. Arguments • arg1 = update/reinstall/rollback • arg2 = slot number Detailed Description This message is displayed when: 1. A reboot job is unable to provide a valid reboot ID. 2. The WSMAN ...
43 SYS Event Messages SYS001 Message The operation was successful. Detailed Description The operation requested successfully completed. Recommended Response Action No response action is required. Category Configuration SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID FA...
44 TMP Event Messages TMP8500 Message I/O Module arg1temperature exceeded operating range. Arguments • arg1 = iom slot name Detailed Description The temperature of the I/O Module identified in the message has increased beyond the operational range. Thermal protection shut down the I/O Module. Factor...
45 USR Event Messages USR8500 Message Excessive login failures from arg1; blocked forarg2seconds. Arguments • arg1 = IP address • arg2 = number Detailed Description Multiple login attempts were unsuccessful from the identified IP address. After detecting this error condition, this IP address will be...
46 VDR Event Messages VDR97 Message Patrol Read corrected a media error on arg1. Arguments • arg1 = VD Name Detailed Description The Patrol Read task has encountered an error such as a bad disk block and remapped data to correct the error. Recommended Response Action No response action is required. ...
47 VFL Event Messages VFL1001 Message Removable Flash Media arg1is present. Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD M...
48 VFLA Event Messages VFLA1000 Message Removable Flash Media arg1is absent. Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFLA = vFlash Absent Severity Severity 3 (Informational) Trap/EventID FALSE LC...
49 VLT Event Messages VLT0300 Message CPU arg1arg2voltage is less than the lower warning threshold. Arguments • arg1 = number • arg2 = name Detailed Description Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. The low voltage may cause the proce...