Page 3 - List of Contents
Danish Interpretation Systems Installation Manual Copyright © 2010 DIS SW 6000 Installation Manual ver 5.3 rev C 27/08/2010 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher. List of Contents List of Contents .........
Page 4 - Introduction
Danish Interpretation Systems Installation Manual Manual 01 19 60011 4 Introduction This manual describes how to design a DCS 6000 Conference system using the SW 6000 Software Packages, how to install the SW 6000 Software Packages and how to setup the system for running the first time. This document...
Page 5 - Preparations and Requirements; Minimum requirement
Danish Interpretation Systems Installation Manual Manual 01 19 60011 5 Preparations and Requirements Minimum requirement The minimum requirements for a PC running an application are: • Min. Pentium 1.5GHz • Min. 2 GB RAM • Min. 10GB HD • CD-ROM drive • RS232 port (on the PC running the CUI applicati...
Page 6 - Supported Operating Systems; Preparations before installation
Danish Interpretation Systems Installation Manual Manual 01 19 60011 6 Supported Operating Systems SW 6000 Software v5.3 support standard installations * of the following operating systems • Windows XP Professional with Service Pack 1 or later. Windows XP Home Edition is not supported. • Windows Vis...
Page 7 - Windows XP Professional Service Pack 2 (and 3) corrections
Danish Interpretation Systems Installation Manual Manual 01 19 60011 7 Windows XP Professional Service Pack 2 (and 3) corrections Windows XP Professional Service Pack 2 and 3 is available from Microsoft; however those service packs have some built in errors, which have to be corrected before running...
Page 8 - Windows Vista corrections
Danish Interpretation Systems Installation Manual Manual 01 19 60011 8 a. Click Start, and then click Run. b. In the Run dialog box, type Firewall.cpl, and then click OK c. In Control Panel, double-click Windows Firewall. d. In the Windows Firewall dialog box, click Add Program on the Exceptions tab...
Page 9 - Windows 7 corrections
Danish Interpretation Systems Installation Manual Manual 01 19 60011 9 e. In the Local DTC Properties dialog box, click on Security tab. f. Click to select the Network DTC Access check box. g. Under the Transaction Manager Communication group, click to select the Allow Inbound check box. To allow th...
Page 11 - Computer Name
Danish Interpretation Systems Installation Manual Manual 01 19 60011 11 Computer Name Before you start installing the SW 6000 software package you must know the name of the computer on which the database is running. To find the computer name on Windows XP follow these steps 1 Open ‘Control Panel’. 2...
Page 12 - System design; Applications
Danish Interpretation Systems Installation Manual Manual 01 19 60011 12 System design Prior to installing the software the system has to be designed, as the SW 6000 Software Package gives options for all in-between a small installation with one PC and a large installation with more than 1000 PCs. Ap...
Page 13 - Installation design; One PC System Design
Danish Interpretation Systems Installation Manual Manual 01 19 60011 13 Installation design The CDA, CUI, CUA, CAA and ECA applications can all be installed on the same PC or all on separate PCs, but this is normal procedure. For performance reason the CUI should be installed at the same PC/Server a...
Page 14 - Chairman control
Danish Interpretation Systems Installation Manual Manual 01 19 60011 14 Chairman control Design characteristics This design is used, where no technician is needed and where the control and administration can be done from the PC placed in the ‘Meeting Room’. Reservations The CU 6005/6010/6011 has to ...
Page 15 - Installation with Multiple PCs
Danish Interpretation Systems Installation Manual Manual 01 19 60011 15 Installation with Multiple PCs Chairman & Technician control Design characteristics This design is used, where a ‘Chairman’ is either controlling the system or monitoring the system and where a ‘Technician’ can take over the...
Page 19 - Software Installation; ‘One PC’ Installation; Installing Prerequisites
Danish Interpretation Systems Installation Manual Manual 01 19 60011 19 Software Installation ‘One PC’ Installation The following installation procedure describes how to install the SW 6000 Software on a PC in a design as described in the section ‘One PC System Design’. Installing Prerequisites 1 In...
Page 23 - ‘Advanced’ Installation
Danish Interpretation Systems Installation Manual Manual 01 19 60011 23 ‘Advanced’ Installation The following installation procedure describes how to install the SW 6000 Software on multiple PCs in designs as described in the section ‘Installation with Multiple PCs’. Two examples are shown. HINT: Th...
Page 29 - PC with: CUA and CAA
Danish Interpretation Systems Installation Manual Manual 01 19 60011 29 PC with: CUA and CAA Installing Prerequisites 1 Insert the CD with the ‘SW 6000 Version 5.3’ Software in the CD-ROM drive in the PC IMPORTANT: If the software is downloaded from the DIS web site the folder ‘SW 6000 Installation’...
Page 32 - License file
Danish Interpretation Systems Installation Manual Manual 01 19 60011 32 and ‘Default database name’ has to be filled in. 9 Create, Test and Save Connection String: Click the ‘Create default ConnectionString’ button to generate the connection string according to the parameters provided. The resulting...
Page 36 - Upgrading from previous versions; Upgrading procedure (using old MSDE Database Server); Upgrading from MSDE Database Server to SQL 2008 Server Express
Danish Interpretation Systems Installation Manual Manual 01 19 60011 36 Upgrading from previous versions Upgrading procedure (using old MSDE Database Server) If you have a previous SW 6000 version already installed using the MSDE Database Server, you can upgrade to version 5.3 as follows. Upgrading ...
Page 37 - Upgrading procedure (using SQL 2008 Server Express); Upgrading from SQL 2005 Server Express to SQL 2008 Server Express
Danish Interpretation Systems Installation Manual Manual 01 19 60011 37 Upgrading procedure (using SQL 2008 Server Express) If you have a previous SW 6000 version already installed using the SQL 2005 Server Express but want to use the SQL 2008 Server Express, you can upgrade as follows. Upgrading fr...
Page 39 - After installation of Software; Customer logo; Creating Database Connections
Danish Interpretation Systems Installation Manual Manual 01 19 60011 39 After installation of Software Customer logo The DIS logo in the CUA application can be exchanged with a customer logo. Do the following: 1 Open the file "CUA logo background.bmp" with a graphics-editing program like ‘Pa...
Page 41 - Advanced settings CUA, CDA; Command line parameters for the CUA and CDA; Advanced settings ECA
Danish Interpretation Systems Installation Manual Manual 01 19 60011 41 Advanced settings CUA, CDA Command line parameters for the CUA and CDA -CONNECTSTRING "connectstring" Use this parameter to specify the database the CUI shall connect to. An example of a valid ‘connectstring’ entry is Pr...
Page 42 - Command line parameters for the ECA; Advanced settings CUI
Danish Interpretation Systems Installation Manual Manual 01 19 60011 42 Command line parameters for the ECA -W Show a communication window when the ECA is started. Don’t use this parameter in normal use. -COMx Specifies the COM port to use. COM1 to COM4 are valid entries. When the COM port is specif...
Page 43 - Command line parameters for the CUI
Danish Interpretation Systems Installation Manual Manual 01 19 60011 43 5 Computer Setup The values in those fields are set during installation. The Computer name must be changed if a database from another installation is restored to this database. Important: The name in “queue” field must not be th...
Page 44 - No ‘Windows’ logon; Automatic logon in XP for a PC not joined to a domain; Automatic logon in XP for a PC joined to a domain
Danish Interpretation Systems Installation Manual Manual 01 19 60011 44 -CONNECTSTRING "connectstring" Use this parameter to specify the database the CUI shall connect to. Valid ‘connectstring’ entry is Provider=SQLOLEDB.1;Initial Catalog=SW6000-1;Data Source=bkk-chn-lap\SW6000;uid=SW 6K11;p...
Page 46 - How to get started; Pre-requisite steps before use; Steps
Danish Interpretation Systems Installation Manual Manual 01 19 60011 46 How to get started Pre-requisite steps before use The system has now been installed successfully. The following sections describe the necessary steps to get started. However please refer to the CAA User Manual, the CUA User Manu...
Page 48 - Un-install SW 6000 Applications
Danish Interpretation Systems Installation Manual Manual 01 19 60011 48 26. Select the delegate who is to be placed in Seat 2 and click >>. Continue until delegates are placed in all seats 27. Click “Hide” 28. Select for each Delegate the User Type, which shall apply for the delegate for this ...
Page 49 - Un-install SW 6000 Databases
Danish Interpretation Systems Installation Manual Manual 01 19 60011 49 1 To un-install select ‘SW6000’ in the list of programs and click ‘Remove’. All the application are then removed. Un-install SW 6000 Databases If a database (SW 6000-1, SW 6000-2, SW 6000-3 or SW 6000-4) has been installed using...
Page 50 - Un-install SQL 2008 Express Server
Danish Interpretation Systems Installation Manual Manual 01 19 60011 50 Problems un-installing the SW 6000 Databases If the SW 6000 Applications have been removed before the SW 6000 databases are removed or the above procedure for removing the SW 6000 Databases fails the database can be removed in t...
Page 51 - Descriptions of the more technical parts; Database; Connect string; Connect string for MSDE
Danish Interpretation Systems Installation Manual Manual 01 19 60011 51 Descriptions of the more technical parts Database To use the SW 6000 applications you need a database. The database contains all data used by the application such as delegate names, microphone information etc. etc. When installi...