2 Index Installation Instructions 3-14 Product Specifi cation 3 Installation 4Cable Access and Wiring 5-8 Installer Advanced Programming Options 8-14 User Instructions 15-31 What is a Programmable Room Thermostat 15 Preset programmes 16-17 Setting Date and Time 18-19 Changing Preset Programmes 19-22...
Page 3 - Product Specifi cation; Installa
3 Installation Instructions Product Specifi cation Please Note: This product should only be installed by a qualifi ed electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations. Thermostat features TP5000 Si TP5000-RF Si TP5000M Si ...
Page 4 - First, remove the wallplate from the back of the unit.; Thermostat and Remote Room Sensor:
4 Installa tion Instruc tions GB Installation First, remove the wallplate from the back of the unit. From the top left hand corner of the wallplate, there must be clearances of at least 15mm to the right, 15mm to the left, 30mm above and 100mm below in order to mount the plug-in module. Thermostat a...
Page 5 - all hard wired models; Battery Installation
5 Installa tion Instruc tions GB 1 2 3 Cable Access Wiring L N D E B C A D E 24V Output Connections, all hard wired models Power Supply Connections M 230V Models M 24V Models Remote Sensor (A version only) Remote Sensor (A version only) 0V Battery Installation When installing the batteries in the TP...
Page 6 - Models with remote sensor inputs; Installer Advanced Programming Options
6 Models with remote sensor inputs Terminal block for remote control/sensing is located on the circuit board above the battery compartment. Installa tion Instruc tions GB S1/D S2/E S1/D S2/E Window or teleswitch contact (NO or NC) S1/D S2/E Teleswitch contact (NC) Window contact (NC) Confi gured for...
Page 7 - N L; Reset the unit by pressing the recessed reset button.; I M P O R T A N T
7 RX1 RX2 & RX3 1 2 3 4 ELECTRONICS N L COM ZONE 1 ON ZONE 1 OFF A ELECTRONICS B C 1 2 3 4 5 6 N L ZONE 1 ON ZONE1 OFF ZONE 2 ON ZONE 3 ON COM TERMINAL 6 RX3 ONLY RX Receiver Wiring (RF models only) 1) For mains voltage operated systems link terminal 2 to mains live supply.2) Power supply to uni...
Page 8 - Installer advanced programming options; User Advanced Programming
8 Installer advanced programming options TP5000 Si incorporates an additional number of advanced features which can be set by the installer to improve the operating effi ciency of the system and where required, to change the user functionality of the product. These are accessed via an Installer Adva...
Page 10 - Option 32 - Enable Off at lower limit; Option 33 - Enable On at upper limit; Setting 0
10 Installa tion Instruc tions GB Option 32 - Enable Off at lower limit This enables an OFF function to be selected if a set point below the lower limit is selected. Press + until Option 32 is displayed, use V and Λ to select required setting. Setting 0 Disabled Setting 1 Enabled (factory setting) O...
Page 11 - Option 36 - Set temperature override rule
11 Installa tion Instruc tions GB Option 36 - Set temperature override rule This establishes the degree of temperature override available to the user. Press + until Option 36 is displayed, use V and Λ to select required setting. Setting 0 No limit (factory setting) Setting 1 Limited to ±2°C Setting ...
Page 12 - Option 70 - Keyboard disable rules
12 Installa tion Instruc tions GB Option 70 - Keyboard disable rules This establishes the degree of functionality of the keyboard available to the user. It is only active if DIL switch 1 is set to “Disabled”. Press + until Option 70 is displayed, use V and Λ to select required setting. Setting 0 Nor...
Page 13 - Option 74 - Date format for calendar clock
13 Installa tion Instruc tions GB Option 74 - Date format for calendar clock This allows date format to be chosen. Press + until Option 74 is displayed, use V and Λ to select required setting. Setting 0 European format (dd/mm/yy), (Factory setting) Setting 1 North American format (mm/dd/yy) Option 8...
Page 14 - until Option 94 is displayed,
14 Installa tion Instruc tions GB Option 94 - Confi gure digital input switch type, “A” models only, (option 90 set to 3) This allows switch type of digital input to be confi gured. Press + until Option 94 is displayed, use V and Λ to select required setting. Setting 0 Contacts NC, open circuit cont...
Page 15 - ser Instruc
15 What is a programmable room thermostat? ... an explanation for householdersA programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set ‘On’ and ‘Off ’ time periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, swi...
Page 16 - Preset programmes; User Instructions
16 An introduction to your programmable room thermostat Your programmable room thermostat allows you to programme diff erent temperatures at diff erent time periods. You can programme one set of times and temperatures for week days with a diff erent set of temperatures for weekend days, this is refe...
Page 17 - Before you start; button with a non-metallic object; Customising the display; Event; Note: these are also times for
17 Note: If set up for 4 events per day, events 3 & 4 are skipped. If set up for 2 events per day, events 2, 3, 4 & 5 are skipped. In both cases the events are re-numbered. Before you start Open the fl ap on the front of the programmer and press the RESET button with a non-metallic object un...
Page 19 - Before you change the preset programmes; Changing the preset programmes in 5/2 day mode; For Weekdays
19 Accepting the preset programmes If you are happy with the preset times shown in the table on page 17you need take no further action. Changing the preset programmes Before you change the preset programmes Your installer will have set the unit to operate in one of the following modes: 5/2 day - one...
Page 20 - For Weekends; Changing the preset programmes in 24 hour mode
20 U ser Instruc tions GB b) Use the + and - buttons to adjust the TIME (press and hold to change in 10 minute increments). c) Use the Λ and V buttons to adjust the required TEMPERATURE . d) Press PROG to move to the next preset time and temperature (Event 2). e) Repeat steps b, c, & d to progra...
Page 22 - User Overrides; Altering the display to show time or temperature
22 U ser Instruc tions GB Programming “B” programme days and events a) Press PROG until the fi rst preset time and temperature (Event 1 for Programme B) appears in the display. b) Use the + and - buttons to adjust the TIME (press and hold to change in 10 minute increments). c) Use the Λ and V button...
Page 23 - User Advanced
23 U ser Instruc tions GB This override will automatically be cancelled at the beginning of the next programmed event. Please note that your installer may have restricted the duration of the override to something other than next event. In this case the override arrow will fl ash to indicate a timed ...
Page 24 - To change from Summer to Winter (clocks back); Remote override into and out of thermostat mode; User; Delay start feature
24 U ser Instruc tions GB Changing the clock forwards and backwards This is handled automatically, however, if the manual changeover has been selected (User Advanced Programming step 3 on page 26) follow the instructions below. To change from Summer to Winter (clocks back) With clock display showing...
Page 25 - Battery replacement (battery models only); When; After replacing the batteries press and release the RESET; and; Installer Advanced Programming
25 U ser Instruc tions GB Optimum start control (OSC) Your thermostat includes an optional optimum start control. This feature allows you to set the time at which you require a room temperature by. The thermostat then calculates how soon before the event time the system must be turned up to ensure t...
Page 26 - Option 3 - Calendar clock rules; To access User Advanced Programming; PROG
26 U ser Instruc tions GB Option 1 - Enable or disable A/B programming (option 41 set to 5+2) This enables or disables the A/B programming option. Press + until Option 1 is displayed, use Λ and V to select required setting. Setting 0 Disabled, unit operates as 5+2 or 24 hour product depending on ins...
Page 27 - Option 10 - Frost/ thermostat mode setting
27 Option 10 - Frost/ thermostat mode setting This feature allows the default frost/thermostat mode temperature to be set. Press + until Option 10 is displayed, use Λ and V to select required setting. 5-40°C - Factory setting is 5°C, but can be changed to any value between 5-40°C. U ser Instruc tion...
Page 29 - ON; rather than turn; on battery failure. This will consume more fuel but will prevent
29 Overview of installer selectable features which may aff ect the operation of your thermostat Temperature range limitation This allows the installer to programme both upper and lower temperature limits. It may limit the upper and lower temperature that you are able to set on the thermostat. Temper...
Page 30 - Partial reset; User full reset; whilst holding down; Installer full reset; Service Interval Timer
30 U ser Instruc tions GB Resetting the unit Partial reset : Press RESET (used to restart micro-computer) if display freezes for any reason. This does not reset any programme, clock or date. It is recommended that this is done at time of installation. User full reset : Press RESET whilst holding dow...
Page 32 - Call your local heating engineer:; For problems relating to your; heating controls; Email our technical department:; For a large print version of these instructions
32 Danfoss Randall Ltd Ampthill RoadBedfordMK42 9ERTel: 01234 364621Fax: 01234 219705 Part No. 40798v02s3-00 02/08 Still having problems? Call your local heating engineer: Name: Tel: For problems relating to your heating controls ... Visit our website: www.danfoss-randall.co.uk Email our technical d...