Crown M600 - Manual
Crown M600 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 4 – • Horizontal (“Side Wall”) Concentric Venting; - Vent system exits the building through an outside wall.; • Vertical Concentric Venting -; CAUTION
- Page 5 – • Vent Option 3
- Page 6 – TABLE 1.1: SUMMARY OF HORIZONTAL VENTING OPTIONS
- Page 7 – ) Permitted Terminals for Vertical Venting -; • Vent Option 8; run towards the boiler:
- Page 8 – FIGURE 1.3c: POSITIONING VENT TERMINAL UNDER OVERHANGS
- Page 9 – TABLE 1.5: SUMMARY OF VERTICAL VENTING OPTIONS
- Page 11 – . Concentric Vent Adapter Kit Installation
- Page 13 – C. Assembly of Crown Concentric Venting; WARNING; Description
- Page 14 – OUTER PIPE ONLY
- Page 15 – through both outer pipes to start this screw.; Use a drill stop or other means to ensure that the drill bit does not; ) Horizontal Terminal Installation
- Page 16 – FIGURE 1.12b: CUTTING OUTER PIPE OF HORIZONTAL TERMINAL
- Page 18 – roof using the fl at roof fl ashing.
- Page 19 – FIGURE 1.13c: COMPLETING VERTICAL TERMINAL INSTALLATION
- Page 22 – Manufacturer of Hydronic Heating Products
BWC150/225 CONCENTRIC VENTING
INSTALLATION
INSTRUCTIONS
These instructions must be affi xed on or adjacent to the boiler.
Models:
•
BWC150
•
BWC225
WARNING
: Improper installation, adjustment, alteration,
service or maintenance can cause property damage, injury,
or loss of life. For assistance or additional information, con-
sult a qualifi ed installer, service agency or the gas supplier.
This boiler requires a special venting system. Read these
instructions carefully before installing.
D
E S I G N E D T O
L
E A D
Manufacturer of Hydronic Heating Products
P.O. Box 14818 3633 I. Street
Philadelphia, PA 19134
Tel: (215) 535-8900 • Fax: (215) 535-9736 • www.crownboiler.com
BWC Series
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
WARNING FAILURE TO VENT THIS BOILER IN ACCORDANCE WITH THESE INSTRUCTIONS COULD CAUSE FLUE GAS TO ENTER THE BUILDING RESULTING IN SEVERE PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH: * Do not attempt to vent this boiler with galvanized, PVC, or any other vent components not listed in Table 1.6. * Do n...
3 Example: A 80/125mm concentric vent system is planned for a horizontally vented BWC150 which has the following components: Standard Radius 90° Elbow 5ft Straight Pipe Standard Radius 90° Elbow 1-1/2ft Straight Pipe 45° Elbow Uncut Terminal Section The Vent Option #3 column in Table 1.1 describes a...
4 TABLE 1.1: SUMMARY OF HORIZONTAL VENTING OPTIONS VENT OPTION # 3 4 CLASSIFICATION USED IN THIS MANUAL HORIZONTAL CONCENTRIC HORIZONTAL CONCENTRIC ILLUSTRATED IN FIGURE 1.2 1.2 VENT PIPE PENETRATION THROUGH STRUCTURE WALL WALL AIR INTAKE PIPE PENETRATION THROUGH STRUCTURE WALL WALL VENT PIPE SIZE 8...