70V Stereo (per channel)
1 kHz
Power
1,200W
600W
1,200W
2,400W
8 ohm Bridge-Mono
4 ohm Stereo (per channel)
8 ohm Stereo (per channel)
CH4
*1 kHz Power: refers to maximum average power in watts
at 1 kHz with 0.5% THD.
*
2,400W
140V Bridge-Mono
1,400W**
2 ohm Stereo (per channel)
2,800W**
4 ohm Bridge-Mono
**
≥
200V line voltage provides 1800W (2 ohm stereo)
and 3600W (4 ohm bridge-mono).
70V Stereo (per channel)
1 kHz
Power
300W
275W
450W
900W
8 ohm Bridge-Mono
4 ohm Stereo (per channel)
8 ohm Stereo (per channel)
CH1
*1 kHz Power: refers to maximum average power in watts
at 1 kHz with 0.5% THD.
*
600W
140V Bridge-Mono
70V Stereo (per channel)
1 kHz
Power
600W
400W
660W
1,320W
8 ohm Bridge-Mono
4 ohm Stereo (per channel)
8 ohm Stereo (per channel)
CH2
*1 kHz Power: refers to maximum average power in watts
at 1 kHz with 0.5% THD.
*
1,200W
140V Bridge-Mono
CH1
C O N T R A C T O R S E R I E S
L
ooking for a quality, constant voltage and low
impedance two channel amplifi er for your res-
taurant, nightclub, retail store, school or house
of worship projects? The Crown
®
“Contractor Series”
amplifi ers are designed just for you.
CH-Series amplifi ers can directly drive “constant
voltage” lines, so you can avoid the expense of
adding step-up transformers for distributed loud-
speaker systems.
All Contractor-Series amplifi ers feature Crown’s
exclusive SST (System Solutions Topologies) expan-
sion system. The SST expansion system makes it
easy to tailor your amplifi er to a specifi c application
or to add future technology as it develops.
With an incredibly wide range of power and fea-
ture/benefi ts, Contractor-Series amplifi ers give the
professional sound contractor more options. Crown
quality is available at the best dollar-per-watt ratio on
the market.
For more details about the Crown Contractor Series,
contact the Crown Technical Support Group at 800-
342-6939 or 574-294-8200. Also, visit the Crown
Audio website at www.crownaudio.com.
Specifi cations
Note: All measurements apply to amplifi ers in stereo
mode with 8 ohm loads and an input sensitivity of 26
dB gain, 1 kHz at rated power unless other otherwise
specifi ed. Specifi cations for units supplied outside
the U.S.A. may vary slightly at different AC voltages
and frequencies.
Power
Output Power:
See power charts below.
Load Impedance:
Safe with all types of loads.
4 and 8 ohm Stereo.
16 ohm (CH1) or 8 ohm (CH2) or 4 ohm (CH4) at
70V Stereo.
4, 8 and 16 ohm Bridge.
32 ohm (CH1) or 16 ohm (CH2) or 8 ohm (CH4) at
140V Bridge.
64 ohm (CH1) or 32 ohm (CH2) at 200V Bridge.
Voltage Gain, 1 kHz, 1.4V sensitivity:
30.5 dB (CH1) or 32.1 dB (CH2) or 34 dB (CH4)
at 8 ohms.
34 dB (CH1) or 34 dB (CH2) or 34 dB (CH4) at
70V.
AC Line Requirements:
Note: North American units are 60 Hz only. All other
models are 50/60 Hz. Voltages are ±10%.
AC Line Current:
100V: 7.6A (CH1) or 11.4A (CH2) or 8.5A (CH4).
120V: 6.3A (CH1) or 9.5A (CH2) or 7.1A (CH4).
230-240V: 3.5A (CH1) or 5.0A (CH2) or
3.7A (CH4).
AC Line Connector:
Detachable 15A IEC connector
with country-specifi c plug.
Performance
Frequency Response, 20 Hz to 20 kHz at 1 watt:
±0.1
dB (CH1, CH2) or ±0.25 dB (CH4).
Phase Response:
±15 degrees deviation from linear
phase from 20 Hz to 20 kHz at 1 watt.
Signal to Noise Ratio, A-Weighted:
Better than 105
dB (CH1, CH2) or 102 dB (CH4) below rated 1-kHz
power.
Total Harmonic Distortion (THD), 1 kHz at rated
power:
0.5% or less true THD from 20 Hz to 20 kHz.
Intermodulation Distortion (60 Hz and 7 kHz at 4:1):
Less than 0.1% (CH1, CH2) or 0.5% (CH4) at rated
power to 30 dB below rated power at 8 ohms.
Damping Factor (8 ohm):
Better than 400 (CH1, CH2)
or 700 (CH4) from 10 Hz to 400 Hz.
Crosstalk, 20 Hz to 20 kHz:
Better than 50 dB below
rated power.
Common Mode Rejection (CMR):
Better than 40 dB
from 20 Hz to 1 kHz.
DC Output Offset (shorted Input):
< ±10 mV.
Features
• Drives multiple impedances, with both low
impedance and high impedance outputs per
channel.
• High-pass filter for each channel provides
low-frequency roll off to eliminate step down
transformer saturation when used in 70V dis-
tributed systems.
• Shallow chassis design, allowing for installa-
tion in most wall-mount racks.
• Rear panel detented level controls allow for
accurate level settings and secure operation.
• “Contractor-Correct” barrier strip output con-
nectors allow for quick and easy connection,
regardless of the load.
• Advanced protection circuitry guards against:
shorted outputs, open circuits, DC, mismatched
loads, general overheating, high-frequency
overloads and internal faults.
• Can be mounted in standard (19-inch (48.3-
cm)) rack, shallow (14-inch (35.56-cm)) rack,
or stacked on top of each other.
• A c c u r a t e , u n c o l o r e d s o u n d w i t h v e r y l o w
distortion for the best in music and voice repro-
duction.
• Three-Year, No-Fault, Fully Transferable War-
ranty completely protects your investment and
guarantees its specifi cations
.
• Crown’s Profi t Protection Plan guarantees quick,
no-questions-asked replacement of your covered
Contractor Series amplifi er should it fail at any
time up to 6 months following date of installation.
CH2
CH4
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.