Crown BSI345 - Manual

Crown BSI345

Crown BSI345 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
Page: / 54

Table of Contents:

  • Page 3 – TABLE 1: BSI SPECIFICATIONS; II Specifications; FIGURE 1: BSI BOILERS - GENERAL CONFIGURATION
  • Page 4 – III Before Installing; National Fuel Gas Code; IV Locating the Boiler; ) The boiler must be installed on a hard level surface.; Warning
  • Page 5 – ) The boiler should be located as close to the chimney as possible.; V Air for Combustion and Ventilation
  • Page 6 – For Buildings of Other than Unusually Tight Construction; National Fuel; For Buildings of Unusually Tight Construction
  • Page 9 – VI Venting
  • Page 10 – screws and support as required.; Removing an Existing Boiler from a Common Chimney; will operate continuously.
  • Page 12 – FIGURE 10: GAS CONNECTION TO BOILER; VII Gas Piping
  • Page 13 – CAUTION; VIII System Piping; General Piping Notes; Installation Guide for Residential Hydronic Heating Systems
  • Page 14 – PIPE SAFETY VALVE DISCHARGE TO A SAFE LOCATION.
  • Page 15 – BETWEEN RISERS
  • Page 16 – IX Indirect Water Heater Piping; IMPORTANT; FIGURE 13: INDIRECT WATER HEATER BOILER-SIDE PIPING
  • Page 17 – X Wiring; BLACK
  • Page 18 – Do; NOT; Indirect Water Heater Wiring
  • Page 19 – FIGURE 15: WIRING INDIRECT WATER HEATER TO BOILER
  • Page 20 – BSI Control System – Sequence of Operation; (Refer to Figures 16 through 19 for ladder and connection diagrams); Sequence of Operation, Standing Pilot
  • Page 23 – #67 LOW WATER CUTOFF
  • Page 24 – XI Start-up and Checkout; Use the following procedure for initial start-up of the boiler:; NOTE; NEVER USE A FLAME TO CHECK FOR GAS LEAKS.
  • Page 25 – WARNING
  • Page 26 – LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH HONEYWELL
  • Page 27 – LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH ROBERTSHAW
  • Page 30 – FIGURE 22a: MAIN BURNER FLAME - 1” BURNERS; DO NOT INSTALL ANY VALVES IN THIS LINE
  • Page 32 – XII Service and Maintenance; On a continuous basis:; Reinstall safety valve and related piping.
  • Page 35 – XIII Troubleshooting
  • Page 36 – : Read page 34 before attempting to use this chart
  • Page 40 – Standing Pilot Ignition System Troubleshooting Chart; Caution; : Read page 34 before
  • Page 41 – Intermittent Ignition System Troubleshooting Chart
  • Page 42 – XIV PARTS; representative or the factory at:
  • Page 48 – punctures due to mishandling.; B. Base Assembly Preparation; tion manual for additional information on placement.; C. Heat Exchanger and Flue Collector Installation; Appendix A: Knockdown Boiler Assembly Instructions; D. Jacket Installation
  • Page 51 – FIGURE A2: JACKET INSTALLATION
  • Page 54 – Manufacturer of Hydronic Heating Products; CROWN; Boiler Co
Loading the manual

1

D

E

S

I

G

N

E

D

T

O

L

E

A

D

Tel: (215) 535-8900 • Fax: (215) 535-9736 • www.crownboiler.com

Manufacturer of Hydronic Heating Products

P.O. Box 14818 3633 I. Street

Philadelphia, PA 19134

BSI Series

Gas-Fired Natural Draft Steam Boilers

INSTALLATION INSTRUCTIONS

These instructions must be affixed on or adjacent to the boiler

WARNING

: Improper installation,

adjustment, alteration, service or
maintenance can cause property
damage, injury, or loss of life. For
assistance or additional informa-
tion, consult a qualified installer,
service agency or the gas
supplier. Read these instructions
carefully before installing.

Models:

BSI069

BSI103

BSI138

BSI172

BSI207

BSI241

BSI276

BSI310

BSI345

BSI379

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE 1: BSI SPECIFICATIONS; II Specifications; FIGURE 1: BSI BOILERS - GENERAL CONFIGURATION

3 TABLE 1: BSI SPECIFICATIONS 2 II Specifications FIGURE 1: BSI BOILERS - GENERAL CONFIGURATION INP UT(M B H) (M BH ) (Sq . ft) (M BH) (% ) " A" "B " "C" "D " (Gal) B SI0 69 S 8 0.0 B SI0 69 E 8 1.9 B SI1 03 S 8 0.0 B SI1 03 E 8 2.0 B SI1 38 S 8 0.3 B SI1 38 E 8 2.0 B...

Page 4 - III Before Installing; National Fuel Gas Code; IV Locating the Boiler; ) The boiler must be installed on a hard level surface.; Warning

4 3 III Before Installing 1) Safe, reliable operation of this boiler depends upon installation by a professional heating contractor in strict accordancewith this manual and the requirements of the authority having jurisdiction. • In the absence of an authority having jurisdiction, installation must ...

Page 5 - ) The boiler should be located as close to the chimney as possible.; V Air for Combustion and Ventilation

5 4 4) Do not install this boiler in a location where gasoline or other flammable vapors or liquids will be stored or used. Do notinstall this boiler in an area where large amounts of airborne dust will be present, such as a workshop. 5) The boiler should be located as close to the chimney as possib...