Crown 32-380ECS - Manual

Crown 32-380ECS

Crown 32-380ECS – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 4 – VII Venting; To install the damper:; Do not force closed damper; Forcing vent damper closed may result in damaged gear train.; must be left; screws and support as required.; VIII Steam Boiler Piping and Trim Installation; 2-475 in Figure 27a in the installation manual.; IX Water Boiler Piping; Refer to installation manual; WARNING
  • Page 5 – XI Control System Wiring; insulated quick connects to the BVS.
  • Page 6 – Figure A: Steam Boiler Wiring
  • Page 7 – Sequence of Operation - Steam Boiler; minal must be in excess of approximately 1.0 uA.; Safety Control Operation - Steam Boilers
  • Page 8 – Figure D: Steam Boiler Control Installation
  • Page 9 – Sequence of Operation - Water Boiler, Less Tankless Heater; 4 volts is present across “B1” and “B2”.
  • Page 10 – Figure E: Blocked Vent Switch Installation
  • Page 11 – Safety Control Operation - Water Boilers; XIII Service in Maintenance
  • Page 12 – INTERMEDIATE CARTON - See Installation Manual; ECS BASE CARTON
  • Page 13 – ECS WATER TRIM CARTON (LESS TANKLESS HEATER)
  • Page 14 – ECS STEAM TRIM CARTON
  • Page 16 – Manufacturer of Hydronic Heating Products
Loading the manual

D

e

s

i

g

n

e

D

t

o

L

e

a

D

Tel: (215) 535-8900 • Fax: (215) 535-9736 • www.crownboiler.com

Manufacturer of Hydronic Heating Products

P.O. Box 14818 3633 I. Street

Philadelphia, PA 19134

Series 32ECS

Gas-Fired Natural Draft Steam or Water Boilers

INStallatIoN SUPPlEMENt FoR:

32-380ECS

32-475ECS

EQUIPPED WItH 24 Volt CoNtRol SYStEMS

WaRNING

: Improper installation,

adjustment, alteration, service or

maintenance can cause property

damage, injury, or loss of life. For

assistance or additional information,

consult a qualified installer, service

agency or the gas supplier. Read

these instructions carefully before

installing.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - VII Venting; To install the damper:; Do not force closed damper; Forcing vent damper closed may result in damaged gear train.; must be left; screws and support as required.; VIII Steam Boiler Piping and Trim Installation; 2-475 in Figure 27a in the installation manual.; IX Water Boiler Piping; Refer to installation manual; WARNING

VII Venting Refer to installation manual. Vent sizing for the 32-380ECS should always be done in accordance with the National Fuel Gas Code. A vent damper can be installed on any 32-380ECS or 32-475ECS equipped with a 24 volt control system except for those with tankless heaters. If a vent damper is...

Page 5 - XI Control System Wiring; insulated quick connects to the BVS.

WARNING All wiring and grounding must be done in accordance with the authority having jurisdiction or, in the absence of such CAUTION Make sure that damper and BVS harnesses are secured so that they do not come in contact with draft hood or steam piping. XI Control System Wiring Wire the boiler in a...

Page 6 - Figure A: Steam Boiler Wiring

“BURNER” “BURNER” TH TR + ROBERTSHAW7000DERHCGAS VALVE VENT DAMPER (NOTE 2) NOTE 2 LESS VENTDAMPER 2. ON BOILERS LESS VENT DAMPER, DAMPER HARNESS NOT USED. RED AND BLUE LEADS ARE JUMPED TOGETHER USING RED JUMPER WIRE. RD RD RD ALARMALARM 2 (NOTE 2) 2. WHEN DAMPER IS NOT USED, DAMPER HARNESS IS REPLA...