AVAILABLE ACCESSORIES

CNLPS-120

Power Supply for CNLGE-8, 120V

CNLPS-277

Power Supply for CNLGE-8, 277V

Specifications for CNLPS (Sold Separately)

Load Ratings

24 Volts AC, 50 VA
For use with CNLGE-8 modules only
Maximum Load: (6) modules

Power Requirements

CNLPS-120:

120 Volts AC, 50/60Hz, single-phase

CNLPS-277:

277 Volts AC, 50/60Hz, single-phase

Connectors

120 VAC:

(1) 2-position captive screw terminal, line power input (CNLPS-120 only)

277 VAC:

(1) 2-position captive screw terminal, line power input (CNLPS-277 only)

COMMON:

(5) Captive screw terminals, output common buss

24VAC:

(5) Captive screw terminals, 24 Volt AC output buss

Fuse:

CNLPS-120: (1) 3AG, 1 Amp, time-lag; CNLPS-277: (1) FLQ 0.5 Amp

Environmental

Temperature:

32° to 104°F (0° to 40°C)

Humidity:

10% to 90% RH (non-condensing)

Enclosure

Occupies 1 module space in a CLC-6 cabinet
(Contact factory for applications requiring CSTC cabinet)

www.crestron.com

|

800.237.2041

The CNLGE-8 module provides 8 channels of switching for non-dimmable lighting
and power loads. Each channel features an isolated SPST mechanically latched
relay, which maintains its state even if power is disrupted. The CNLGE-8 occupies a
single module space in any CSTC or CLC-6 cabinet (not including required CNLPS
power supply), and is designed to communicate with the PAC2 control system, or
any Crestron control system, via the Cresnet control network.

> 8 channels of switching for non-dimmable loads

> Mechanically-latched, isolated, single-pole / single-throw relays

> Each switched circuit maintains its state in case of power failure

> Occupies 1 module space in a CSTC lighting cabinet

> Requires CNLPS power supply

> Controlled by PAC2 or PAC2M automation control system

SPECIFICATIONS

Load Ratings

Relay Closure:

20A @ 125V AC (Tungsten); 20A @ 277V AC (Resistive or Fluorescent

Ballast); 0.5 HP @ 110-125V AC; 1.5 HP @ 220-277V AC;
Note: May not be compatible with some high inrush current loads

Power Requirements

24 Volts AC; requires one CNLPS power supply for every (6) CNLGE-8 modules

Connectors

1 - 8:

(8) 2-position captive screw terminals, isolated Class 1 SPST relay switch circuits

Split-coil, mechanically-latching SPST relay closure

NET:

(1) 4-pin 5mm detachable terminal block, Cresnet slave port

Connects to Cresnet control network

24VAC:

Attached 2-conductor Class 2 cable, relay power input

Connects to CNLPS power supply (sold separately)

Controls

ID CODE:

(2) Rotary DIP Switches, set Cresnet ID

LED Indicators

POWER:

Indicates DC power supplied from Cresnet network

ACTIVITY:

Indicates communication with Cresnet system

1 – 8:

Indicate when each relay is closed

Environmental

Temperature:

32° to 104°F (0° to 40°C)

Humidity:

10% to 90% RH (non-condensing)

Enclosure

Occupies 1 module space in a CLC-6 cabinet
(Contact factory for applications requiring CSTC cabinet)

S p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e . D o c . 4 8 3 1 1 2 / 0 7

©2007 Crestron Electronics, Inc. All brand names, product names and trademarks are the property of their respective owners.

Crestron Electronics, Inc. 15 Volvo Drive

l

Rockleigh, NJ 07647

Tel: 800.237.2041 / 201.767.3400

l

Fax: 201.767.1903

Crestron CNLGE-8