Table of Contents:
- Page 2 – To mount bin thermostat in electrical box:; Figure 1
- Page 4 – FIGURE 2
- Page 5 – ELECTRICAL BOX ASY; Figure 4; TO CHASSIS; Figure 3
IMI CORNELIUS INC. 2004
March 2, 2004
630460064INS
1
Rev A
IMI CORNELIUS INC
g
One Cornelius Place
g
Anoka, MN 55303-6234
Telephone (800) 238-3600 Facsimile (800) 535-4321
INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 630000408
These Bin Stat kits apply to all “I” Series Ice makers
Table 1. Loose–Shipped Parts
Item No.
Part No.
Name
Qty.
1
630900413
Spacer, Hex 5/8” Long x 8–32 SS
1
2
70894
Screw MA 08–32 TRPH 24 SS
1
3
51348
Spacer
1
4
630000413
Thermostat Asy
1
5
620037008
Bin Stat Support
1
6
630460064INS
Installation Instruction, Thermostat
1
7
168833002
Washer SR 4W SS E#8
1
1. Disconnect power.
2. Remove front cover of the unit and the electrical box cover plate.
3. Carefully insert the coiled capillary tube through the bottom hole in the electrical box where the elec-
trical wires are coming through (see Figure 4).
4. If there is not a hole already in the chassis base, drill a
½
” hole in the chassis base as indicated in
Figure 3.
5. Straighten approximately 12” of cap tube to go through hole. Re–coil the remainder. Do not disturb
coiled end.
6. Insert the “1/4” diameter wire form support into the coiled end of capillary tube and insert the assem-
bly through the hole in the chassis base. Route capillary tube to follow support as closely as pos-
sible.
7. Remove the 8–32 nut (closest to the
½
” DIA hole) that holds the compartment wall to the base. The
adapter kits that have a single level, adapter kits P/N’s 02390, 630200153, 08006, 02388, 08004,
630000191 and 08010) require a 7/8” high spacer be used to mount the binstat support. Thread the
8–32 x 5/8” hex spacer on to the compartment stud. Then fasten the thermostat support to the hex
spacer using the
¼
” high plastic spacer, #8 flat washer and 8–32 x
¾
” long phil. head screw. The
spacers are not to be used on the elevated adapter kits. Refer to Figure 2.
8. Any excess capillary tubing must be pulled back into the compressor compartment to prevent ice
from damaging it during dispenser operation.
9. Seal
½
” diameter hole with sealant (RTV).
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
IMI CORNELIUS INC. 2004 March 2, 2004 630460064INS 2 Rev A 10. To mount bin thermostat in electrical box: A. Clean the mounting area by rubbing briskly with Scotch Brite pad (see Figure 4 for location). B. Wipe down the cleaned area with rubbing alcohol and let dry. C. Pull paper strip off of double...
IMI CORNELIUS INC. 2004 March 2, 2004 630460064INS 4 Rev A 1/4 SPACER FIGURE 2 8–32 X 3/4 PHMS 5/8 SPACER 8–32 NUT (PART OF ICEMAKER) WASHER WASHER 620037008, BIN STAT SUPT 620037008, BIN STAT SUPT. BIN STAT SUPT ASY FOR ALL ELEVATED ADAPTOR LID KITS CAPILLARY ASY CAPILLARY TUBE ICEMAKER E-BOX ELEVA...
IMI CORNELIUS INC. 2004 March 2, 2004 630460064INS 5 Rev A OF UNIT WITHOUT COVER. * DIMENSION IS FROM FRONT TOP VIEW OF 1230 CHASSIS PLATE RIGHT HAND LINER LEFT HAND LINER ICE DROP ZONE ICE ZONE DROP DROP ZONE ICE ZONE DROP ICE 4.25* 1.50 15.41 1/2” DRILL ELECTRICAL BOX ASY CLEAN MOUNTING AREA WITHS...