Cornelius IWC530 - Manual

Cornelius IWC530

Cornelius IWC530 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
Page: / 83

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Page
  • Page 4 – MODEL AND SERIAL LOCATION; “I” SERIES CUBER
  • Page 6 – SPECIFICATIONS – 60 HZ; ICE CUBER SPECIFICATION
  • Page 10 – SPECIFICATIONS – 50 HZ
  • Page 13 – SPECIFICATIONS – 50 HZ, REMOTE CONDENSER; MODEL; Volts
  • Page 14 – GENERAL; FREIGHT DAMAGE CLAIMS PROCEDURE; and request an inspection from the deliverer.
  • Page 15 – INSTALLATION INSTRUCTIONS; LOCATION OF EQUIPMENT; The following steps refer to the set-up of the ice bin and the cuber:; DISPENSER INSTALLATION
  • Page 17 – Note: Leave all panels on the cuber until it is in place on the bin.; PLUMBING CONNECTIONS
  • Page 18 – clearance on all sides and top for proper air circulation?; START-UP AND CHECK OUT; C). The water pump will operate when the evaporator cools to 25
  • Page 19 – Cleaning the Water System and Evaporator; Clean; Repeat the procedure 3 times.
  • Page 20 – SANITIZING PROCEDURES; To be performed only after cleaning the ice machine:; areas with the solution. Or use a commercial sanitizer.; DUMP CYCLE
  • Page 21 – You have the option of selecting dump cycle intervals of:
  • Page 22 – All printed capacity ratings are; ICE PRODUCTION CHECK
  • Page 23 – LED INDICATORS; Water dump valve
  • Page 25 – CIRCUIT BOARD DIAGNOSTIC PROCEDURE; One of these two conditions will exist:
  • Page 26 – RESTORING ICE THICKNESS POTENTIOMETER TO FACTORY SETTING; Making Adjustments; turn, rest several seconds, then adjust another 360; When the LED; starts to flash, stop turning; . You have reached the original factory setting.
  • Page 27 – Condenser sensor; RESET OPERATION; Evaporator Switches; Switch Notes; Harvest Safety Termination; VOLTAGE CHECKS; Evaporator Proximity Switch
  • Page 29 – WATER REGULATING VALVE; Also discharge water temperature below 108
  • Page 31 – Note: See compressor run-on condition check procedure on page 31.; COMPRESSOR & STARTING COMPONENT CHECK-OUT PROCEDURE; ing must not be less than 90% of 50 HZ rating.; Relay; Potential –; This; Current –; 0% and run capacitors; Compressor
  • Page 32 – LEAK DETECTION; Either of these methods may; SYSTEM EVACUATION & RECHARGING
  • Page 33 – REFRIGERANT DEFINITIONS
  • Page 34 – HIGH PRESSURE SAFETY SWITCH
  • Page 35 – AVERAGE OPERATING CHARACTERISTICS; IP Units
  • Page 54 – TROUBLESHOOTING
  • Page 66 – REFRIGERATION AND WATER SYSTEMS
  • Page 67 – Refrigeration and water system
  • Page 68 – Refrigeration and Water Systems
  • Page 71 – REFRIGERATION AND WATER SYSTEM
  • Page 72 – REMOTE CONDENSER
  • Page 74 – INSTALLATION INSTRUCTIONS REMOTE CONDENSERS; until the remote condenser and line set installation is complete.
  • Page 75 – NOTE; should it ever be required.
  • Page 76 – REMOTE CONDENSER LOCATION; distance; Measured rise
  • Page 78 – VIOLATION OF THE CLEAN AIR ACT OF JULY, 1992.
  • Page 80 – to
  • Page 81 – DO NOT; Always leak check entire system after recharge.
  • Page 82 – THIS PAGE LEFT BLANK INTENTIONALLY
Loading the manual

12/1/94

166240004

Revised: 3/4/96

THE HOTTEST MACHINES ON ICE

T

I" Series

Ice Cube Machine

SERVICE MANUAL & MAINTENANCE GUIDE

(Includes Installation Instructions)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; Page

i 166240004 TABLE OF CONTENTS Page MODEL AND SERIAL LOCATION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . “I” SERIES CUBER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SERIAL NUMBER EXPLANATION 1 ...

Page 4 - MODEL AND SERIAL LOCATION; “I” SERIES CUBER

1 166240004 12/1/94Rev 3/4/96 MODEL AND SERIAL LOCATION “I” SERIES CUBER Condenser Discharge AirDeflector (as required)* Bin Adapter (as required)* Model/SerialNumber Location *Bin adapters and condenser discharge air deflector may be equipped depending on your location or the size ofthe storage bin...

Page 6 - SPECIFICATIONS – 60 HZ; ICE CUBER SPECIFICATION

3 166240004 12/1/94 R e v 3/4/96 SPECIFICATIONS – 60 HZ ICE CUBER SPECIFICATION MODEL IAC322E60IAC330E60 IACS227E60 IWC322E60IWC330E60 IWCS227E60 IAC522E60 IAC522E60L IAC530E60 IAC530E60L IWC522E60 IWC522E60L IWC530E60 IWC530E60L UNIT Volts 230 230 230 230 Phase 1 1 1 1 Hertz 60 60 60 60 No. Wires 2...

Other Cornelius Models

All Cornelius Other