- Page 2 – TABLE OF CONTENTS
- Page 3 – GENERAL INFORMATION; INTRODUCTION; Location of Chiller; must
- Page 4 – Electrical Connections; FIGURE 1. “CH” SERIES CHILLERS
- Page 5 – Chiller Operation; WARNING: NEVER OPERATE THE CHILLER WITH THE PANELS REMOVED.; Process Liquid Flow; coming power supply leads at the terminal strip.; scription of the option for complete explanation.; procedure and pressures.; Trip; and; Norm; phase voltage, where the unit is applied.
- Page 6 – COOLING OPERATION; FIGURE 2. CONTROL PANEL; readout that indicates system liquid temperature (2; CONTROL POWER SWITCH/LIGHT; nate under the following conditions:
- Page 7 – TAINED. MAKE SURE CHILLER POWER IS ”OFF” PRIOR TO FILLING RESERVOIR.; Thermostat Control; CH SERIES TEMPERATURE CONTROLLER; CHILLER MAINTENANCE; Condenser
- Page 8 – striction caused by contaminants.
- Page 9 – TROUBLESHOOTING; components or electrical wiring.
- Page 11 – FIGURE 4. CABINET SECTION EXPLODED VIEW
- Page 12 – CABINET SECTION
- Page 13 – ELECTRICAL BOX ASSEMBLY
- Page 14 – FIGURE 6. PUMP AND TANK ASSEMBLY
- Page 15 – PUMP AND TANK ASSEMBLY
- Page 16 – WARRANTY; equipment model number, serial number and the date of purchase.
- Page 17 – THIS PAGE LEFT BLANK INTENTIONALLY
- Page 18 – One Cornelius Place
CHILLER (“CH” SERIES)
Operator’s Manual
Models:
CH 951-A
CH 1500-A
CH 1502-A
CH 1503-A
PRINTED IN U.S.A
IMI CORNELIUS INC; 1995--99
Ó
IMI CORNELIUS REMCOR INC
g
500 REGENCY DRIVE
g
GLENDALE HEIGHTS, IL 60139--2268
Telephone (800) 551--4423
Facsimile (800) 519--4423
Part No. 92266
December 5, 1995
Revised: July, 1999
Revision C
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or operating this equipment
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
i 92266 TABLE OF CONTENTS Page GENERAL INFORMATION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INTRODUCTION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNPACKING AND INSPECTION...
1 92266 GENERAL INFORMATION INTRODUCTION The REMCOR ”CH”Series Recirculating Liquid Chiller is designed to provide an accurate, reliable, and user-- friendly system for cooling a continuous flow of pure liquid and keep that liquid at a constant temperature in vari- ous closed loop or tank cooling ap...
2 92266 It is very important that the air intake and discharge sides of the chiller are not obstructed by other free standing objects. A minimum of two feet of space on all four sides of the chiller will be sufficient to prevent air flow ob- structions. It is also important to direct any hot air dis...