Cornelius 2849959200 - Manual

Cornelius 2849959200

Cornelius 2849959200 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
Page: / 7

Table of Contents:

  • Page 2 – NOTE: Only qualified Personnel should install this Kit.; melted from the evaporator coils.; INSTALLING ICE BANK CONTROL KIT
  • Page 3 – RESTORING UNIT OPERATION; CONTENT WATER WHERE A LOCAL WATER PROBLEM EXIST.
  • Page 5 – FIGURE 3. UNIT TOP VIEW
  • Page 7 – ICE BANK CONTROL BULB; FIGURE 4. UNIT WIRING DIAGRAM
Loading the manual

April 5, 1999

569000264

E

IMI Cornelius Inc; 1999

IMI CORNELIUS INC

g

One Cornelius Place

g

Anoka, MN 55303-6234

Telephone (800) 238-3600 Facsimile (612) 422-3246

INSTALLATION INSTRUCTIONS

WHITE RODGERS ICE BANK CONTROL KIT (P/N 569000263)

ON

UNIVERSAL C–750 PRE–MIX DISPENSERS

KIT FITS MODELS 2849949200, 2849949020, 2849959200, and 2849959020

IMPORTANT: All old parts (Ice bank Control Module and Mounting Bracket, Ice Bank Control Probe, and
the Ice Bank Control Probe Holder) must
be returned to IMI Cornelius Inc, Attention: John Engstrom.
Send returned parts to the above address.

Read and understand these instructions thoroughly before installing this kit. Retain these instructions as part of
your equipment manual.

Table 1. Loose-Shipped Parts

Item

No.

Part No.

Name

Qty.

1

315794000

Ice Bank Control, White Rodgers

1

2

3528

Box, Ice Bank Control

1

3

186125000

Grommet,

1

4

313457000

Label, Hazard Shock

1

5

187188000

Screw, Machine, No. 8–32 X .250

2

6

3529

Holder, Control Bulb

1

7

180024000

O–Ring

2

8

3575

Electrical Wire, Black

1

9

3576

Electrical Wire, Red

1

10

325282000

Screw, Self Drilling, No. 8–18 Thread X .500 Long, No. 2 Point

2

11

32038900

Snap Bushing

1

12

040056000

Wire Tie

4

13

8901

Electrical Wire Terminal

1

14

330181000

Hex Nut

1

PREPARING DISPENSER FOR KIT INSTALLATION

WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure
Dispenser is disconnected from power source before attempting to install this kit.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - NOTE: Only qualified Personnel should install this Kit.; melted from the evaporator coils.; INSTALLING ICE BANK CONTROL KIT

2 569000264 NOTE: Only qualified Personnel should install this Kit. 1. Disconnect Unit product inlet lines from product tanks, then open dispensing valves to relieve systems pressures. 2. Disconnect electrical power from the Unit, open hinged top cover, then drain water tank. CAUTION: Never use an i...

Page 3 - RESTORING UNIT OPERATION; CONTENT WATER WHERE A LOCAL WATER PROBLEM EXIST.

3 569000264 5. Place product coils assembly back in position inside the Unit. Make sure ice bank control capillary tube is routed from ice bank control bulb up along right front side (facing front of Unit) of the Unit and on up to theice bank control as shown in Figure 3. 6. Connect product tubes, c...

Page 5 - FIGURE 3. UNIT TOP VIEW

5 569000264 FIGURE 3. UNIT TOP VIEW ICE BANK CONTROL ASSEMBLY (ITEMS 1 AND 2) AGITATOR MOTOR BRACKET UNIT WIRING HARNESS HAZARD SHOCK LABEL (ITEM 4) CAPILLARY TUBE SNAP BUSHING (ITEM 11) GROMMET (ITEM 3)

Other Cornelius Models

All Cornelius Other