Page 2 - For internal use only:; COPYRIGHT; Initial Version
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 2 For internal use only: File: MSEBX800-900_Detailed_V1.0.doc Path: R:\HANDBUCH\MSEBX\MSEBX800\MSEBX800-900_Detailed_V1.0.doc COPYRIGHT 2008 BY DIGITAL-LOGIC AG This publication is protected by copyright and all rights are reserved. No part ...
Page 3 - Table of Contents
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 3 Table of Contents 1. P REFACE .....................................................................................................................................................5 1.1. Trademarks .....................................................
Page 7 - CE Conformity; This symbol indicates a heat sensitive component.; Safety Instructions; This symbol shows safety instructions for the operator to follow.
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 7 1.8. Explanation of Symbols CE Conformity This symbol indicates that the product described in this manual is in compliance with all applied CE standards. Caution, Electric Shock! This symbol and title warn of hazards due to electrical shocks (>...
Page 8 - Applicable Documents and Standards; 005 PCI Special Interest Group. All rights reserved.
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 8 1.9. Applicable Documents and Standards The following publications are used in conjunction with this manual. When any of the referenced specifications are superseded by an approved revision, that revision shall apply. All documents may be obtained...
Page 11 - not; The Swiss Association for Quality and Management
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 11 1.12. Swiss Quality 100% Made in Switzerland DIGITAL-LOGIC is a member of "Swiss-Label" This product was not manufactured by employees earning piecework wages This product was manufactured in humane work conditions All employees who worke...
Page 12 - VERVIEW; Standard
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 12 2. O VERVIEW 2.1. Standard Features The MICROSPACE EBX is a miniaturized modular device incorporating the major elements of a PC/AT compatible computer. It includes standard PC/AT compatible elements, such as: Powerful GEODE LX800/900 with 500/60...
Page 17 - All information is subject to change without notice.
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 17 Operating Temperature Specification: MIL-810-501 MIL-810-502 Extended temperature range: SM800PCX (500MHz) -40°C to +70°C Security e1 Not planned UL Not planned ETS 301 Not planned CE/SEV Yes Safety AR385-16 If all signals are externally filtered...
Page 22 - Description; High frequency Radiation (to meet EN55022)
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 22 2.8. Incompatibilities to a Standard PC/AT None. 2.9. MSEBX800/900 Related Application Notes # Description 80 High frequency Radiation (to meet EN55022) Application Notes are availble at http://www.digitallogic.com support, or on any Application ...
Page 23 - Information is taken from the data sheet of the pbq ER10280.
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 23 2.11. Thermoscan Product Part Number Serial Number Version MSEBX800 811202 45320210010 0.2 SM800PCX 805164 45316410032 2.1 SODIMM DDR 1GB 870672 - - Software Windows XP SP2 running desktop Top view, passive cooled: t [min] fCPU [MHz] I [A] P [W] ...
Page 24 - REPARATION; The smartModule must be firmly attached to the board with screws.; Do
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 24 3. P REPARATION 3.1. Important Information Warning, ESD Sensitive Device! Place the embedded computer board on an isolated, ESD-protected surface. Also ensure that all equipment, tools and people are fully protected against ESD. Attention! The sm...
Page 26 - To install or change the RAM, follow these steps:; Photo 1
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 26 3.3. RAM Assembly/Disassembly To install or change the RAM, follow these steps: 1. Unmount the smartModule by removing the 4 screws marked in red (see the photo from the previous page). 2. To change the RAM: a. Using your thumbnails, gently push ...
Page 27 - Photo 3
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 27 e. Slowly push the RAM down until the clips "click" into place (Photo 3). Photo 3 3. To install a RAM: a. Carefully place the side of the RAM with the connectors into the slot. There is only one correct way to place the RAM in the slot du...
Page 29 - The ISA-Bus may have some minor incompatibilities, see Chapter 6.; . This signal indicates that the DMA operation can begin.; normal operation; and should be driven with an; active low; . The line must be held high until
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 29 4. B US S IGNALS 4.1. PC104 Bus Note... The ISA-Bus may have some minor incompatibilities, see Chapter 6. AEN, output Address Enable: used to degate the microprocessor and other devices from the I/O channel to allow DMA transfers to take place. l...
Page 30 - s after reset is inactive.
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 30 /Master, input This signal is used with a DRQ line to gain control of the system. A processor or DMA controller on the I/O channel may issue a DRQ to a DMA channel in cascade mode and receive a /DACK. /MEMCS16, input MEMCS16 Chip Select: signals ...
Page 32 - System Boot Times
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 32 5. D ETAILED S YSTEM D ESCRIPTION 5.1. Boot Time System Boot Times Definitions/Boot-Medium Quick Boot* Normal Boot MSEBX800-500MHz with RTC-Backup Battery Memory 256MB shared 8MB for Video time [s] From Floppy disk Boot from Setup-Disk1 MS-DOS v6...
Page 34 - Floppy Disk Interface
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 34 5.2.4. Floppy Disk Interface Supported Floppy Formats Capacity Drive size Tracks Data rate DOS version 1.2 MB 5-1/4" 80 500 KHz 3.0 - 6.22 720 K 3-1/2" 80 250 KHz 3.2 - 6.22 1.44 M 3-1/2" 80 500 KHz 3.3 - 6.22 Floppy Interface Configu...
Page 36 - In case the BIOS needs to be recovered:; Jumper J9
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 36 5.4. BIOS Recovery In case the BIOS needs to be recovered: 1. Set Jumper J9 . 2. Start the MSEBX800/900. 3. Open the BIOS. 4. Remove Jumper J9 . 5. Load the default BIOS settings. 6. Save the settings. 7. Restart the MSEBX800/900. Jumper J9
Page 37 - Connector Structure
DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0 37 6. D ESCRIPTION AND L OCATION OF THE C ONNECTORS Connector Structure Pin Remarks X1 Power Input 2 Power Jack X2 ATX Power Connector 20 X11 LVDS 2x 10 RM2.54 X14 Video IN 2 SMA X15 LCD 2x 25 RM2.54 X20 MIC IN - Phone Jack X22 Line Out Front - Phon...