Comfort Glow CHDV34PA - Manual

Comfort Glow CHDV34PA

Comfort Glow CHDV34PA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:
  • Page 3 – OWNER’S MANUAL; LOCAL CODES; OPERATION
  • Page 4 – CLEARANCES; Figure 2 - Common Fireplace Locations; Flush with a wall; Figure 3 - Fireplace Bottom Dimensions
  • Page 5 – Nailing Tabs; Continued; Figure 6 - Framing Clearances for Corner Installation; Location of Vent Termination; GENERAL VENTING; Figure 7 - Clearances for Combustible Mantels; Mantel Depth
  • Page 6 – Figure 8 - Minimum Clearances for Vent Terminations
  • Page 7 – WARNING: This gas fireplace; INSTALLATION PLANNING; For Horizontal Termination:; Installing Vent System in a Chase; WARNING: Never run the vent; For Vertical Termination:
  • Page 8 – Figure 10 - Snorkel Termination with Drainage Pipe; WARNING: Do not recess vent; Snorkel
  • Page 9 – Vent Opening; Figure 12 - Vent Opening Requirements; Note
  • Page 10 – Elbow; Horizontal Venting; Horizontal Venting; CBVK Vent Kit Shown
  • Page 11 – Venting with Two 90; Elbows
  • Page 12 – Cathedral Ceiling Installation
  • Page 13 – Vertical Termination Configurations; Figure 25 - Vertical Rigid Venting Configuration Using Two 90; Venting with One 90; Figure 26 - Vertical Rigid Venting Configuration Using One 90; finished ceiling
  • Page 14 – Vertical Venting; CRVF Kit Shown; Comfort Glow Rigid Venting; Number Description
  • Page 15 – Comfort Glow Flexible Venting
  • Page 16 – CHECK GAS TYPE; Your fireplace is designed to be used; Blower Assembly
  • Page 17 – WARNING: Never touch the; Peel off the backing paper and stick the; WARNING: Failure to position; Connect or reconnect gas supply to fire-; b. If your fireplace system installation; Figure 30 - Mounting Blower to Firebox; Figure 31 - Locating Thermal Switch Against Back of Firebox
  • Page 18 – Figure 35 - Gas Connection; Installation Items Needed; Cap Pipe Nipple Tee Joint
  • Page 19 – WARNING: Never use an open; Figure 36 - Attaching Flexible Gas Line to Control Valve
  • Page 20 – Figure 37 - Manual Shutoff Valve; Open; Figure 39 - Checking Gas Joints for Natural Gas Fireplace; Gas Valve
  • Page 21 – CAUTION: Do not operate this; Figure 45 - Removing/Replacing Glass Door; Screw; Installing Remote Receiver; Attach the terminal wires to the battery.; Figure 41 - Control Valve Terminals; Receiver
  • Page 22 – Figure 46 - Installing Rear Brick Panel and Retainer Brackets; Rear Brick Panel
  • Page 23 – WARNING: The glass door; Ember Material
  • Page 24 – Figure 53 - Control Valve; Gas Control Knob
  • Page 25 – CGHRC Series Operation:; The burners may light if; OPTIONAL REMOTE; Thermostat Control Operation; All remote control accessories must; To turn the pilot off,
  • Page 26 – To turn the pilot off, turn; Figure 56 - Pilot Assembly; If you are; • turn fireplace off (see To Turn Off Gas to
  • Page 27 – PILOT AND BURNERS; ment Parts on page 31.; VENTING SYSTEM
  • Page 28 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; nance, page 27) or replace pilot assembly; OBSERVED PROBLEM
  • Page 29 – nance, page 27) or replace burner orifice
  • Page 31 – SPECIFICATIONS; When Gas Pressure Is Too Low; WIRING DIAGRAM; CAUTION: Label all wires prior to disconnection when servicing; PARTS UNDER WARRANTY
  • Page 33 – PARTS LIST; DIRECT-VENT FIREPLACE; PART NUMBER
  • Page 34 – ACCESSORIES
  • Page 35 – HEARTH BASE
  • Page 36 – For information about this warranty write:; INTERNATIONAL; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
Loading the manual

DIRECT-VENT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

NATURAL GAS MODEL CHDV34NA

PROPANE/LP GAS MODEL CHDV34PA

Save this manual for future reference.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assis-
tance or additional information con-
sult a qualified installer, service
agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes.

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

— Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.

— This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases, unless a certified kit is
used.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:

2 105983 DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) CHDV34NA, PA SAFETYINFORMATION 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used. 2. For propane/LP fireplace, do not placepro...

Page 3 - OWNER’S MANUAL; LOCAL CODES; OPERATION

3 105983 OWNER’S MANUAL PRODUCTIDENTIFICATION Install and use fireplace with care. Followall local codes. In the absence to local codes,use the current National Fuel Gas CodeANS Z223.1, also known as NFPA 54*(USA) or the current CAN/CGA-B149[.1 or.2] Installation Codes (Canada). *Available from: Ame...

Page 4 - CLEARANCES; Figure 2 - Common Fireplace Locations; Flush with a wall; Figure 3 - Fireplace Bottom Dimensions

4 105983 DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) CHDV34NA, PA Fireplace size D x FW x RW 34" 18 1 / 2 " 34 3 / 8 " 14" PRE-INSTALLATIONPREPARATION LOCATION AND SPACEREQUIREMENTS Determine the safest and most efficient loca-tion for your Comfort Glow direct-vent fire-place. Make su...