Chamberlain SL 1000-XI - Manual

Chamberlain SL 1000-XI

Chamberlain SL 1000-XI – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
Page: / 39

Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 4 – SAFETY SUMMARY; installation to be sure they are functioning properly.
  • Page 5 – BASIC INSTALLATION HINTS AND RULES; WARNING
  • Page 6 – PART 1; A. LOCATION AND LAYOUT; from dragging on itself.
  • Page 7 – ground level to prevent water entrance.
  • Page 8 – Important: Do not rely on metallic conduit for earth ground.; The shelf space provided is approximately 4” x 10” x 18” high.; E. TELEPHONE CONNECTION; Do not run telephone and AC power wires in the same conduit; F. OTHER CONNECTIONS; INSTALLATION NOTES
  • Page 9 – PART 2; A. MOUNTING GATE OPERATOR
  • Page 10 – procedures have been completed.; Failure to observe this warning may result in the Power; B. INSTALLING LOCK HASP
  • Page 11 – Dress all wiring inside the switch box and install cover.
  • Page 12 – POWER UP PROCEDURE; CAUTION; NOTE; connect the OPEN terminal to the COMMON terminal.; G. SETTING LIMIT CAMS; Each cam rotation (360
  • Page 13 – gates, reverse Left Gate and Right Gates procedures.; until they are set properly.; H. GATE SENSITIVITY ADJUSTMENTS
  • Page 14 – finely, or they may change with the time of day or seasons.; Figure 15. Gate Sensitivity Adjustments Location.
  • Page 16 – POWER FAIL OPERATION OPTION CONNECTION; DO NOT shut off the Gate Operator Power switch unless
  • Page 17 – K. CONNECTING INPUT WIRING
  • Page 18 – L. POST INSTALLATION PROCEDURES; (the Gate Open Direction switch) is set to the correct position.; unit power; switch; Maximum Retry Count; in programming step 9.
  • Page 19 – Alternate Action; close the gate, disable ATG and RT in programming steps 6 and 8.; Power Fail Option
  • Page 20 – cycle the gate to its
  • Page 21 – PART 3; POWER FAIL OPERATION OPTION
  • Page 22 – PART 4; To test an input, connect the input terminal to the COMMON
  • Page 23 – Mostly in cold weather or mornings:
  • Page 24 – The power was not cycled after changing the setting of switch S1.
  • Page 25 – THERE IS SLACK IN THE GATE
  • Page 27 – IF MAX RUN TIME LED IS TURNED ON ONLY
  • Page 28 – must not be loose on the shaft. Tighten set screws if loose
  • Page 29 – Refer to Figure 18, above, to perform the following instructions.
  • Page 30 – ) the boxes across as you perform your maintenance procedures.; MAINTENANCE SCHEDULE TABLE
  • Page 31 – APPENDIX A; CONTROLS, INDICATORS, INPUTS AND ADJUSTMENTS
  • Page 32 – CONTROLS
  • Page 34 – ADJUSTMENTS
  • Page 35 – APPENDIX B
  • Page 36 – APPENDIX C; Both gate operators must have the same settings for:; DO NOT INTERCHANGE SIGNAL AND COMMON TERMINALS
  • Page 37 – GLOSSARY; Interrupt Bar or Edge:
  • Page 38 – NOTICE TO CANADIAN USERS; electric inspection authority, or an electrician, as appropriate.; Ringer Equivalence Number; (REN) assigned to each terminal device provides an indication of
  • Page 39 – COPYRIGHT; FOR TECHNICAL SUPPORT; Part Number
Loading the manual

Doc. 6001194 (01

Doc. 6001194 (01

Doc. 6001194 (01

Doc. 6001194 (01-

-

-

-20259)

20259)

20259)

20259)

Rev C

Rev C

Rev C

Rev C


















INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS

FOR THE

FOR THE

FOR THE

FOR THE

MODEL

MODEL

MODEL

MODEL

SL 1000

SL 1000

SL 1000

SL 1000

-

-

-

-

X1

X1

X1

X1

SLIDE GATE OPERATOR

SLIDE GATE OPERATOR

SLIDE GATE OPERATOR

SLIDE GATE OPERATOR

((((—

—65 BOARD)

65 BOARD)

65 BOARD)

65 BOARD)


















"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS

Rev C Doc 6001194 (01-20259) TABLE OF CONTENTS SAFETY SUMMARY....................................................................................................... 1 BASIC INSTALLATION HINTS AND RULES ................................................................ 2 PART 1 SITE PREPARATION ..........

Page 4 - SAFETY SUMMARY; installation to be sure they are functioning properly.

Rev C Doc 6001194 (01-20259) 1 of 36 SAFETY SUMMARY It is imperative that everyone involved in the installation or operation of the LiftMaster model SL 1000-X1 Slide Gate Operator reads the following warnings. WARNING! • A vehicle gate is a large, heavy object that is moved by an electric motor. A m...

Page 5 - BASIC INSTALLATION HINTS AND RULES; WARNING

Rev C Doc 6001194 (01-20259) 2 of 36 BASIC INSTALLATION HINTS AND RULES PLEASE READ THIS SECTION VERY CAREFULLY BEFORE BEGINNING YOUR INSTALLATION. In the sections that follow, detailed procedures are discussed for each step required to install a model SL 1000-X1 system. In addition to these specifi...

Other Chamberlain Models