1 Page 1
2 Page 2
Page: / 2
Loading the manual
Page 1

fx-95MS

  

fx-500MS

User’s Guide

CASIO Worldwide Education Website

http://edu.casio.com

CASIO EDUCATIONAL FORUM

http://edu.casio.com/forum/

EEE Yönetmeli¤ine Uygundur

1. Important Information

• The displays and illustrations (such as key markings) shown in

this User’s Guide are for illustrative purposes only, and may differ
somewhat from the actual items they represent.

• The contents of this manual are subject to change without notice.
• In no event shall CASIO Computer Co., Ltd. be liable to anyone

for special, collateral, incidental, or consequential damages in
connection with or arising out of the purchase or use of this product
and items that come with it. Moreover, CASIO Computer Co., Ltd.
shall not be liable for any claim of any kind whatsoever by any other
party arising out of the use of this product and the items that come
with it.

• Be sure to keep all user documentation handy for future reference.

2. Sample Operations

Sample operations in this manual are indicated by a

icon. Unless

specifically stated, all sample operations assume that the calculator
is in its initial default setup.

3. Initializing the Calculator

Perform the following procedure when you want to initialize the
calculator and return the calculation mode and setup to their initial
default settings. Note that this operation also clears all data currently
in calculator memory.

O

!

N

(CLR)

3

(All)

=

4. Safety Precautions

Battery

• Keep batteries out of the reach of small children.
• Use only the type of battery specified for this calculator in this

manual.

5. Handling Precautions

•

Dim figures on the display of the calculator indicate that battery
power is low. Continued use of the calculator when the battery
is low can result in improper operation. Replace the battery
as soon as possible when display figures becomes dim. Even
if the calculator is operating normally, replace the battery at
least once every two years. A dead battery can leak, causing
damage to and malfunction of the calculator. Never leave a
dead battery in the calculator.

•

The battery that comes with the calculator discharges slightly
during shipment and storage. Because of this, it may require
replacement sooner than the normal expected battery life.

•

Do not use an oxyride battery* or any other type of nickel-based
primary battery with this product. Incompatibility between
such batteries and product specifications can result in shorter
battery life and product malfunction.

•

Avoid use and storage of the calculator in areas subjected to
temperature extremes, and large amounts of humidity and dust.

•

Do not subject the calculator to excessive impact, pressure,
or bending.

•

Never try to take the calculator apart.

•

Use a soft, dry cloth to clean the exterior of the calculator.

•

Whenever discarding the calculator or batteries, be sure to
do so in accordance with the laws and regulations in your
particular area.

* Company and product names used in this manual may be registered

trademarks or trademarks of their respective owners.

6. Removing the Hard Case

Before using the calculator, slide
i t s h a r d c a s e d o w n w a r d s t o
remove it, and then affix the hard
case to the back of the calculator
a s s h o w n i n t h e i l l u s t r a t i o n
nearby.

RJA526807-001V01

SA1208-A Printed in China

© 2012 CASIO COMPUTER CO., LTD.

E

7. Turning Power On and Off

Press

O

to turn on the calculator.

Press

1A

(OFF) to turn off the calculator.

Auto Power Off

Your calculator will turn off automatically if you do not perform any
operation for about 10 minutes.

8. Adjusting Display Contrast

1. Press the

,

key a number of times until

you reach the setup screen shown to the
right.

2. Press

c

.

3. Use

d

and

e

to adjust contrast.

4. After the setting is the way you want, press

A

.

Important:

If adjusting display contrast does not improve display

readability, it probably means that battery power is low. Replace
the battery.

9. Reading the Display

The display of the calculator shows expressions you input, calculation
results, and various indicators.



Input expression




Calculation result



Indicators

10. Specifying the Calculation Mode

When you want to perform this type of
operation:

Perform this key
operation:

General calculations

N

1

(COMP)

Standard deviation

N

2

(SD)

Regression calculations

N

3

(REG)

Equation solution

NN

1

(EQN)

Note:

• The initial default calculation mode is the COMP Mode.

• Mode indicators appear in the upper part of the display. Be sure to
check the current calculation mode (COMP, SD, REG) and angle unit
setting (Deg, Rad, Gra) before beginning a calculation.

11. Configuring the Calculator Setup

Pressing the

,

key more than once displays additional setup

screens. Underlined ( ___ ) settings are initial defaults.

1

Deg

2

Rad

3

Gra

Specifies degrees,

radians or grads as the angle unit for value
input and calculation result display.

Note:

In this manual, the

v

symbol next to a sample operation

indicates degrees.

1

Fix

2

Sci

3

Norm

Specifies the

number of digits for display of a calculation
result.

Fix:

The value you specify (from 0 to 9) controls the number of decimal

places for displayed calculation results. Calculation results are
rounded off to the specified digit before being displayed.
Example: 100 ÷ 7 = 14.286 (Fix 3)

Sci:

The value you specify (from 1 to 10) controls the number of

significant digits for displayed calculation results. Calculation results
are rounded off to the specified digit before being displayed.
Example: 1 ÷ 7 = 1.4286

×

10

–1

(Sci 5)

Norm:

Selecting one of the two available settings (

Norm 1

, Norm

2) determines the range in which results will be displayed in non-
exponential format. Outside the specified range, results are displayed
using exponential format.
Norm 1: 10

–2

|

x

|, |

x

|

10

10

Norm 2: 10

–9

|

x

|, |

x

|

10

10

Example: 1 ÷ 200 = 5

×

10

–3

(Norm 1); 0.005 (Norm 2)

b

d

e

d

e

a + b

i

r

∠

θ

1

a+b

i

2

r

∠

(EQN Mode only)

Specifies either rectangular

coordinates (

a

+

b

i

) or polar coordinates (

r

∠

) for EQN Mode

solutions. The “r

∠

” indicator is displayed while polar coordinates

(

r

∠

) are selected.

1

ab/c

2

d/c

Specifies either mixed fraction (ab/c) or improper

fraction (d/c) for display of fractions in calculation results.

1

Dot

2

Comma

Specifies whether to display a dot or a

comma for the calculation result decimal point. A dot is always
displayed during input.

Dot:

Period decimal point, comma separator

Comma:

Comma decimal point, period separator

Initializing Calculation Mode and Setup

To return the calculation mode and setup to the initial defaults shown
below, press

O

!

N

(CLR)

2

(Mode)

=

.

Calculation Mode:

COMP

Angle Unit:

Deg

Exponential Display Format:

Norm 1

k

Fraction Display Format:

a b/c

Decimal Point Character:

Dot

12. Inputting Expressions and Values

4

×

sin30

×

(30 + 10

×

3) = 120

v

4

*

s

30

*(

30

+

10

*

3

)=

Note:

• The memory area used for calculation input can hold 79

“steps”. One step is taken up each time you press a number key
or arithmetic operator key (

+

,

-

,

*

,

/

). A

!

or

a

key

operation does not take up a step, so inputting

!

W

(

3

'

), for

example, takes up only one step. • Whenever you input the 73rd
step of any calculation, the cursor changes from “_” to “

k

” to let you

know memory is running low.

Calculation Priority Sequence

When the priority of two expressions is the same, the calculation is
performed from left to right.

1st

Function with parentheses: Pol(

x

,

y

), Rec(

r

,

)

2nd

Type A functions: With these functions, the value is
entered and then the function key is pressed. (

x

3

,

x

2

,

x

−1

,

x

!, ° ’ ”,

m

,

m

1

,

m

2

,

n

, °,

r

,

g

)

3rd

Powers and roots: ^(

x

y

),

x

'

4th

Fractions

5th

Implied multiplication of

π

,

e

(natural logarithm base),

memory name, or variable name: 2

π

, 3

e

, 5A,

π

A, etc.

6th

Type B functions: With these functions, the function key is
pressed and then the value is entered. (

'

,

3

'

, log, ln,

e

x

, 10

x

, sin, cos, tan, sin

−1

, cos

−1

, tan

−1

, sinh, cosh, tanh,

sinh

−1

, cosh

−1

, tanh

−1

, (−))

7th

Implied multiplication of Type B functions: 2

'

3, Alog2, etc.

8th

Permutation (

n

P

r

), combination (

n

C

r

)

9th

Multiplication, division (

×

, ÷)

10th Addition, subtraction (+, –)

• The negative sign (–) is treated as a Type B function, so particular

care is required when the calculation includes a high-priority Type
A function, or power or root operations.

Example: (–2)

4

= 16; –2

4

= –16

Making Corrections During Input

• Use

d

and

e

to move the cursor to the location you want.

• Press

D

to delete the number or function at the current cursor

position.

• Press

!D

(INS) to change to an insert cursor

t

. Inputting

something while the insert cursor is on the display inserts the input
at the insert cursor position.

• Pressing

!D

(INS), or

=

returns to the normal cursor from the

insert cursor.

13. Basic Calculations

Fraction Calculations

2 + 1 = 1

3 2 6

1

2

$

3

+

1

$

2

=

1

{

1

{

6.

Note:

• Mixing fractions and decimal values in a calculation will cause

the result to be displayed as a decimal value. • Fractions in calculation
results are displayed after being reduced to their lowest terms.

To switch a calculation result between improper fraction and
mixed fraction format:

Press

1

$

( d/c ).


To switch a calculation result between fraction and decimal
format:

Press

$

.

Percent Calculations

150

×

20% = 30

150

*

20

1

=

(%)

30.

Calculate what percentage of 880 is 660. (75%)

660

/

880

1

=

(%)

75.

Increase 2500 by 15%. (2875)

2500

*

15

1

=

(%)

+

2875.

Discount 3500 by 25%. (2625)

3500

*

25

1

=

(%)

-

2625.

Discount the sum of 168, 98, and 734 by 20%. (800)

168

+

98

+

734

=

G1

~

(STO)

-

(A)

a-

(A)*

*

20

1

=

(%)

-

800.

* As shown here, if you want to use the current Ans (answer) memory

value in a mark up or discount calculation, you need to assign the
Ans memory value into a variable and then use the variable in the
mark up/discount calculation.

300 grams are added to a test sample originally weighing
500 grams, producing a final test sample of 800 grams. What
percent of 500 grams is 800 grams? (160%)

300

+

500

!

=

(%)

160.

What is the percentage change when a value is increased
from 40 to 46? (15%)

46

-

40

!

=

(%)

15.

k

k

k

k

Degree, Minute, Second (Sexagesimal)
Calculations

The following is the input format for a sexagesimal value: {degrees}

$

{minutes}

$

{seconds}

$

.

Note:

You must always input something for the degrees and minutes,

even if they are zero.

2°20´30˝ + 39´30˝ = 3°00´00˝

2

$

20

$

30

$

+

0

$

39

$

30

$

=

3°0°0.

Convert 2°15´18˝ to its decimal equivalent.

2

$

15

$

18

$

=

$

2.255

(Converts decimal to sexagesimal.)

!

$

(

←

)

2°15°18.

Multi-Statements

You can use the colon character (:) to connect two or more
expressions and execute them in sequence from left to right when
you press

=

.

3 + 3 : 3

×

3

3

+

3

S

r

(:) 3

*

3

=

6.

Disp

=

9.

Using Engineering Notation

A simple key operation transforms a displayed value to engineering
notation.

Transform the value 1234 to engineering notation, shifting the

decimal point to the right.

1234

=

W

1.234×10

3

W

1234.×10

0

Calculation History

In the COMP Mode, the calculator remembers up to approximately
150 bytes of data for the newest calculation. You can scroll through
calculation history contents using

f

and

c

.

1 + 1 = 2 2 + 2 = 4 3 + 3 = 6

1

+

1

=

2

+

2

=

3

+

3

=

6.

(Scrolls back.)

f

4.

(Scrolls back again.)

f

2.

Note:

Calculation history data is all cleared whenever you press

O

,

when you change to a different calculation mode, or whenever you
initialize modes and settings.

Replay

While a calculation result is on the display, you can press

d

or

e

to edit the expression you used for the previous calculation.

4 × 3 + 2.5 = 14.5

4

*

3

+

2.5

=

14.5

4 × 3 − 7.1 = 4.9

(Continuing)

d

YYYY

-

7.1

=

4.9

Answer Memory (Ans)

The last calculation result obtained is stored in Ans (answer) memory.
Ans memory contents are updated whenever a new calculation result
is displayed. In addition to

=

, Ans memory contents are also updated

with result whenever you press

!

=

(%),

m

,

!

m

(M–), or

!~

(STO) followed by a letter (A through F, or M, X, or Y).

To divide the result of 3

×

4 by 30

3

*

4

=

(Continuing)

/

30

=

123 + 456 = 579

123

+

456

=

579.

789 – 579 = 210

(Continuing) 789

-

G

=

210.

Variables (A, B, C, D, E, F, X, Y)

Your calculator has eight preset variables named A, B, C, D, E, F,
X, and Y.

To assign the result of 3 + 5 to variable A

3

+

5

1t

(STO)

y

(A)

8.

To multiply the contents of variable A by 10

(Continuing)

S

y

(A)

*

10

=

80.

To recall the contents of variable A

(Continuing)

t

y

(A)

8.

To clear the contents of variable A

0

1t

(STO)

y

(A)

0.

Independent Memory (M)

You can add calculation results to or subtract results from independent
memory. The “M” appears on the display when there is any value
other than zero stored in independent memory.

To clear the contents of M

0

1t

(STO)

l

(M)

0.

k

k

k

k

k

k

k

k

To add the result of 10

×

5 to M

(Continuing)

10

*

5

l

50.

To subtract the result of 10 + 5 from M

(Continuing)

10

+

5

1

l

(M–)

15.

To recall the contents of M

(Continuing)

t

l

(M)

35.

Note:

Variable M is used for independent memory.

Clearing the Contents of All Memories

Independent memory and variable contents are retained even if you
press

A

, change the calculation mode, or turn off the calculator.

Perform the following procedure when you want to clear the contents
of all memories.

p

!,

(CLR)

1

(Mcl)

=

14. Function Calculations

π

:

π

is displayed as 3.141592654, but

π

= 3.14159265358980 is

used for internal calculations.

e

:

e

is displayed as 2.718281828, but

e

= 2.71828182845904 is

used for internal calculations.

sin, cos, tan, sin

−1

, cos

−1

, tan

−1

:

Trigonometric functions. Specify

the angle unit before performing calculations. See

1

.

sinh, cosh, tanh, sinh

−1

, cosh

−1

, tanh

−1

:

Hyperbolic functions. The

angle unit setting does not affect calculations. See

2

.

°,

r

,

g

:

These functions specify the angle unit. ° specifies degrees,

r

radians, and

g

grads. Input a function from the menu that appears

when you perform the following key operation:

1G

(DRG

'

).

See

3

.

10

x

,

e

x

:

Exponential functions. See

4

.

log

:

Logarithmic function. See

5

.

ln

:

Natural logarithm to base

e

. See

6

.

x

2

,

x

3

, ^(

x

y

),

'

'

,

3

'

'

,

x

'

'

,

x

−1

:

Powers, power roots, and

reciprocals. See

7

.

Pol, Rec

:

Pol converts rectangular coordinates to polar coordinates,

while Rec converts polar coordinates to rectangular coordinates.
See

8

.

Pol(

x

,

y

) = (

r

,

)

Rec(

r

,

) = (

x

,

y

)

Specify the angle unit
before performing
calculations.
Calculation result

θ

is

displayed in the range
of −180°

θ

180°.

Rectangular
Coordinates (Rec)

Polar
Coordinates (Pol)

x

!

:

Factorial function. See

9

.

Ran#

:

Generates a 3-digit pseudo random number that is less than

1. See

10

.

n

P

r

,

n

C

r

:

Permutation (

n

P

r

) and combination (

n

C

r

) functions. See

11

.

Rnd

:

The argument of this function is made a decimal value and

then rounded in accordance with the current number of display digits
setting (Norm, Fix, or Sci). With Norm 1 or Norm 2, the argument is
rounded off to 10 digits. See

12

.

Note:

Using functions can slow down a calculation, which may delay

display of the result. To interrupt an ongoing calculation before its
result appears, press

A

.

Examples

sin 30°= 0.5

v

s

30

=

0.5

sin

−1

0.5 = 30°

v

1

s

(sin

−1

) 0.5

=

30.

sinh 1 = 1.175201194

w

s

(sinh) 1

=

1.175201194

cosh

–1

1 = 0

w1

c

(cosh

−1

) 1

=

0.

π

/2 radians = 90°, 50 grads = 45°

v

(

1

E

(

π

)

/

2

)

1G

(DRG

'

)

c

(R)

=

90.

50

1G

(DRG

'

)

d

(G)

=

45.

To calculate

e

5

×

2 to three significant digits (Sci 3)

N

2

(Sci)

3

1i

(

e

x

) 5

*

2

=

2.97×10

2

log 1000 = 3

l

1000

=

3.

To calculate ln 90 (= log

e

90) to three significant digits (Sci 3)

N

2

(Sci)

3

i

90

=

4.50×10

0

1.2

×

10

3

= 1200

1.2

*

10

W

=

1200.

(–5

2

)

3

= –15625

(

-

5

x

)

M

3

=

–15625.

32

5

= 2

5

1

M

(

x

'

) 32

=

2.

To calculate

'

2

×

3 (= 3

'

2 = 4.242640687...) to three

decimal places (Fix 3)

N

1

(Fix)

3

1

2

*

3

=

4.243

k

k

1

1

2

2

3

3

4

4

5

5

6

6

7

7

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Casio
Model
fx-500MS
Document type
Manual
Language(s)
English
Pages
2
File size
585.4 KB
Format
PDF

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.