Carrier ZN030-105 - Manual
Carrier ZN030-105 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 11 – Table 2 — Operating Weights of Options and Accessories (lb)
- Page 12 – Table 3 — Supply Fan Drive Data; Table 4 — Power Exhaust Fan Drive Data
- Page 19 – CAUTION
- Page 22 – Fig. 14 — Weight Distribution and Center of Gravity
- Page 23 – Condensate Drain Connections —
- Page 35 – PE VFD —; Fig. 37 — Economizer Hood Location — 48ZT,ZW Units
- Page 36 – Fig. 38 — Large Economizer Hood Assembly
- Page 37 – DISCONNECT SIZE
- Page 39 – Fig. 44 — Field Power Wiring Connections; Fig. 43 — Factory-Installed Disconnect Location
- Page 40 – Table 7 — Electrical Data, 48ZG,ZN030 Units
- Page 41 – Table 8 — Electrical Data, 48ZG,ZN035 Units
- Page 42 – Table 9 — Electrical Data, 48ZG,ZN040 Units
- Page 51 – Air Pressure Tubing —
- Page 52 – Fig. 47 — Auxiliary Control Box Details
- Page 53 – Supply-Fan Shipping Brackets —; Fig. 49 — Auxiliary Control Box Details
- Page 54 – Remove TXV Shipping Blocks —; Shipping blocks; Fig. 53 — Return/Exhaust Fan Shipping Brackets; Fig. 54 — Foam TXV Shipping Blocks
- Page 55 – Fig. 56 — Front View of Compressor
- Page 56 – Installing Flue/Inlet Hoods —; Table 17 — 48Z Series Staged Gas Implementation
- Page 57 – Fig. 61 — Flue Outlet Hood
- Page 58 – Table 18 — Flue and Inlet Hood Usage; Fig. 65 — Inlet Hood Assembly
- Page 59 – Table 19 — SGC Thermistor Designations; Install Unit Accessories —; Comfort; MUST
- Page 60 – Table 20 — CCN Connection Approved
- Page 61 – Smoke Control Modes —; Table 21 — Smoke Control Modes; Fig. 67 — Field Control Thermostat Wiring
- Page 62 – Fig. 69 — Space Temperature Averaging Wiring
- Page 63 – Fig. 70 — Heat Interlock Relay Wiring
- Page 64 – Fig. 74 — Fan Status Switch Wiring
- Page 65 – Fig. 77 — Return Air Smoke Detector Wiring
- Page 66 – Fig. 80 — CCN Connections
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53480060-01
Printed in U.S.A.
Form 48Z-8SI
Pg 1
4-09
Replaces: 48Z-7SI
Installation Instructions
CONTENTS
Page
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . 1,2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59
Jobsite Survey
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Unit Placement
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Roof Mount
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Slab Mount
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Curb Gasketing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Field-Fabricated Ductwork
. . . . . . . . . . . . . . . . . . . . . . . 2
Rigging
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Condensate Drain Connections
. . . . . . . . . . . . . . . . . 23
Install Outdoor Hoods
(48ZG,ZN,Z6,Z8 Units)
. . . . . . . . . . . . . . . . . . . . . . . . . 33
• UNIT SIZES 030-050
• UNIT SIZES 055-105
Install Economizer Hoods (48ZT,ZW Units)
. . . . . . 35
• INSTALL SMALL HOODS
• INSTALL LARGE HOODS
Field Wire Routing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
• UNIT SIZES 030-050
• UNIT SIZES 055-105
Field Electrical Connections
. . . . . . . . . . . . . . . . . . . . 36
• POWER WIRING
Air Pressure Tubing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
• INLET GUIDE VANES
• VARIABLE FRQUENCY DRIVE
• MODULATING POWER EXHAUST
• RETURN/EXHAUST POWER EXHAUST
Supply-Fan Shipping Brackets
. . . . . . . . . . . . . . . . . . 53
• UNIT SIZES 030-050
• UNIT SIZES 055-070
• UNIT SIZES 075-105
Return/Exhaust Fan Shipping Brackets
(48Z6,Z8 Units)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Remove TXV Shipping Blocks
. . . . . . . . . . . . . . . . . . . 54
Compressor Mounting
. . . . . . . . . . . . . . . . . . . . . . . . . . 55
Gas Piping
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Optional Staged Gas Control
. . . . . . . . . . . . . . . . . . . . 55
Installing Flue/Inlet Hoods
. . . . . . . . . . . . . . . . . . . . . . 56
Supply Air Thermistors
(Staged Gas Units Only)
. . . . . . . . . . . . . . . . . . . . . . 56
Install Unit Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . 59
CONTROLS INSTALLATION
. . . . . . . . . . . . . . . . . . 59-66
Constant Volume Units
. . . . . . . . . . . . . . . . . . . . . . . . . . 59
• CONTROL WIRING
Variable Air Volume Units
. . . . . . . . . . . . . . . . . . . . . . . 59
Optional and Accessory Control Wiring
. . . . . . . . . 60
Carrier Comfort Network
®
(CCN) Interface
. . . . . . . 60
Smoke Control Modes
. . . . . . . . . . . . . . . . . . . . . . . . . . . 61
GENERAL
This installation instruction contains basic unit installation
information, including installation of thermostats and remote
temperature sensors.
For additional information and service instructions, refer to
the Controls and Troubleshooting literature also enclosed in
this literature packet.
The 48ZT,ZW units are equipped with standard integral
economizer and high-capacity power exhaust.
The 48Z6,Z8 units are equipped with factory-installed
return/exhaust fans.
The staged gas control (SGC) option adds the capability to
control the rooftop unit’s gas heating system to a specified sup-
ply air temperature set point for purposes of tempering a cool
mixed-air condition.
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions of cleaning coils and filters and replacing filters. All
other operations should be performed by trained service per-
sonnel. When working on air-conditioning equipment, observe
precautions in the literature, tags and labels attached to the unit,
and other safety precautions that may apply.
Follow all safety codes, including ANSI (American Nation-
al Standards Institute) Z223.1. Wear safety glasses and work
gloves. Use quenching cloth for unbrazing operations. Have
fire extinguisher available for all brazing operations.
WARNING
Before performing service or maintenance operations on
unit, turn off main power switch to unit. Electrical shock
could cause personal injury.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electri-
cal switch; do not use any phone in your building. Immedi-
ately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions. If you cannot reach
your gas supplier, call the fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service, or
maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information, con-
sult a qualified installer, service agency, or the gas supplier.
WEATHERMASTER
®
48ZG,ZN030-105
48ZT,ZW,Z6,Z8075-105
Single Package Gas Heating and Electric Cooling Units
with Direct Spark Ignition and
COMFORT
LINK™ Controls
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
11 Table 1E — Physical Data (48ZT,ZW075-105) (cont) LEGEND Table 2 — Operating Weights of Options and Accessories (lb) *Includes hood. BASE UNIT 48ZT,ZW075 48ZT,ZW090 48ZT,ZW105 POWER EXHAUST Centrifugal, 22 x 20 in., 1 11 / 16 in. shaft diameter (Any motor available on any unit) Total Hp 20 30 40 5...
12 Table 3 — Supply Fan Drive Data *Sizes 040,050 only. NOTE: Part numbers are Browning Manufacturing Corp. reference. Table 4 — Power Exhaust Fan Drive Data *High-Efficiency Motor Option. †Premium-Efficiency Motor Option. **Applies to both motor options. NOTE: Part numbers are Browning Manufacturin...
19 Fig. 9 — Rigging Label — Size 030-050 Units (Standard Chassis) Fig. 8 — Gasket Location on Roof Curb (48ZT,ZW075-105 Units) CAUTION NOTICE TO RIGGERS 1. ALL PANELS MUST BE IN PLACE WHEN RIGGING.2. DO NOT ATTEMPT TO FORK THESE UNITS. UNIT WEIGHT A B ECONOMIZER lb kg in. mm in. mm lb kg 48Z030 5770...