  • Page 2 – FEATURES AND BENEFITS
  • Page 3 – SPECIFICATIONS; Heating Capacity and Efficiency; * See Accessory List for part numbers available.
  • Page 4 – MODEL NUMBER NOMENCLATURE; Example of Model Number; FURNACE COMPONENTS
  • Page 5 – ACCESSORIES
  • Page 8 – Venting System Length Calculations; The Total Equivalent Vent Length (TEVL) for; Example 1; long radius elbows and a factory accessory concentric vent; Example 2
  • Page 11 – RETURN AIR TEMPERATURE; C) db or intermittent operation down to 55; SUPPLY AIR; MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS; ELBOW
  • Page 12 – DOWNFLOW SUBBASE; Assembled; FURNACE; Concentric Vent Kit; installed in downflow applications.
  • Page 13 – MEDIA FILTER CABINET; B Opening; TYPICAL WIRING SCHEMATIC
  • Page 14 – DIMENSIONAL DRAWING; Vent and Combustion air pipes through blower compartment must
  • Page 15 – GUIDE SPECIFICATIONS; General
Loading the manual

1

59SP5A

Performance™ Boost, Single --- Stage

4 --- Way Multipoise

Condensing Gas Furnace

Series 100

Product Data

A11263

The 59SP5A Multipoise Performance

Boost Condensing Gas

Furnace features SEER--boosting year--round electrical efficiency
when paired with a compatible condensing unit. Energy efficiency

is at the heart of this furnace with up to 96.5% AFUE gas

efficiency and the electrically--efficient basic ECM blower motor.
This gas furnace also features 4--way multipoise installation

flexibility, and is available in six model sizes. The 59SP5A can be
vented for direct vent/two--pipe, ventilated combustion air, or

single--pipe applications. All units meet California Air Quality

Management District emission requirements, are design certified in
Canada, and are certified for mobile/manufactured home use.

STANDARD FEATURES

S

Quiet operation. Compare for yourself at HVACpartners.com.

S

Most sizes meet ENERGY STAR

R

Version 4.0 criteria for gas

furnaces: 95+ AFUE; AMACF electrical rating; 2% or less
cabinet airflow leakage.

See table on Page 2.

S

High--efficiency basic ECM multiple--speed blower motor for
electrically efficient operation all year long in heating, cooling
and continuous fan operation.

S

Humidistat

Control compatible; dehumidification input for

better comfort.

S

SmartEvap

technology helps control humidity levels in the

home when used with a compatible humidity control system.

S

ComfortFan

technology allows control of continuous fan

speed from a compatible thermostat.

S

Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.

S

Silicon Nitride Power Heat

Hot Surface Igniter.

S

External Media Filter Cabinet included.

S

4--way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional venting
through--the--cabinet downflow venting capability.

S

Single--speed inducer motor, and single--stage gas valve.

S

Self diagnostics with SuperBrite LED.

S

Approved for Twinning applications with accessory kit (60--14
through 120--22 models, only).

S

Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.

S

Adjustable blower speed for heating, cooling and continuous fan

S

Aluminized--steel primary heat exchanger.

S

Stainless--steel condensing secondary heat exchanger.

S

Propane convertible (see Accessory list).

S

Factory--configured ready for upflow applications.

S

Fully--insulated casing including blower section.

S

Convenient Air Purifier and Humidifier connections.

S

Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.

S

Installation flexibility: (sidewall or vertical vent).

S

Residential installations may be eligible for consumer financing
through the Retail Credit Program.

S

Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.

TM

Select Models

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FEATURES AND BENEFITS

2 SAP ORDERING NO. CASING DIMENSIONS (IN.) RATED HEATING OUTPUT† HEATING AIRFLOW COOLING CFM @ 0.5 ESP (in. W.C.) MOTOR HP SPEED MEDIA CABINET SUPPLIED (IN.) H D W BTUH AFUE ENERGY STAR HEATING CFM HEATING ESP (in. W.C.) 59SP5A040E14--10 35 29.5 14.2 39,000 96.5%  695 0.1 925 1/2 - 5 16 59SP5A040E1...

Page 3 - SPECIFICATIONS; Heating Capacity and Efficiency; * See Accessory List for part numbers available.

3 SPECIFICATIONS Heating Capacity and Efficiency 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22 Input High Heat (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000 Output High Heat (BTUH) 39,000 39,000 58,000 58,000 78,000 78,000 97,000 117,000 Certified Temperature Rise Range ...

Page 4 - MODEL NUMBER NOMENCLATURE; Example of Model Number; FURNACE COMPONENTS

4 MODEL NUMBER NOMENCLATURE 59 T N 6 A 060 V 17 -- -- 14 S - Single StageT - Two StageM - Modulating C - ComfortP - PerformanceN - Infinity S - StandardE - Energy EfficientV - Variable Speed 14 - 14.2”17 - 17.5”21 - 21.0”24 - 24.5” 08 - 800 CFM10 - 1000 CFM12 - 1200 CFM14 - 1400 CFM16 - 1600 CFM18 -...

Other Carrier Models